Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for South Pekin, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 138ft / 41.8mTotal length
  • $261,000Total costs
  • 12,995Total average daily traffic
  • 514Total average daily truck traffic
  • 15,126Total future (year 2032) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for South Pekin
  • No street view available for this location

New bridges in South Pekin, IL - historical statistics
  • New bridges - historical statistics
  • 51950-1959
  • 61960-1969
  • 21970-1979
  • 12000-2009
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.5%Very good
  • 12.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
  • 37.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.5%Very good
  • 12.5%Satisfactory
  • 37.5%Fair
  • 37.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 37.5%Very good
  • 37.5%Satisfactory
  • 25.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.1%Very good
  • 21.4%Good
  • 57.1%Satisfactory
  • 14.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 16.7%Good
  • 66.7%Satisfactory
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 903029,  Location: SE-12-T23NR5W (Lat: 40.454483,  Lng: -89.606214),  Route carried "on" structure: County highway ,  Year Built: 1967,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 13.82m (45.34ft),  Average Daily Traffic: 1,350 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,774 (year 2032),  Design Load: HS 20,  Features Intersected: MACKINAW RIVER,  Facility Carried by Structure: CH-11 (FAS 2462)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.529,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 38.4m (126.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Very good,  Channel: Good,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: December 2020,  Other Special Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 903042,  Location: SE-22-T24NR4W (Lat: 40.515064,  Lng: -89.644981),  Route carried "on" structure: Other road ,  Year Built: 1957,  Status: Open,  Structure Length: 1.76m (5.77ft),  Average Daily Traffic: 1,900 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,720 (year 2032),  Design Load: H 15,  Features Intersected: LOST CREEK,  Facility Carried by Structure: FAS 463 - 5TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.504,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.9m (55.4ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 18.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.47m (8.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $174,000,  Roadway Improvement Cost: $17,000,  Total Project Cost: $261,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 903062,  Location: N.CTR-17-T23NR5W (Lat: 40.447942,  Lng: -89.691139),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Open,  Structure Length: 9.02m (29.59ft),  Average Daily Traffic: 900 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 914 (year 2032),  Design Load: HS 15,  Features Intersected: MACKINAW RIVER,  Facility Carried by Structure: WAGONSELLER RD-TR6
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.492,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: December 2020,  Other Special Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 903101,  Location: S.CTR-26-T24NR5W (Lat: 40.494714,  Lng: -89.637108),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 1.76m (5.77ft),  Average Daily Traffic: 525 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 753 (year 2032),  Design Load: H 15,  Features Intersected: LOST CREEK,  Facility Carried by Structure: FURROW RD - TR 141
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.644,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.9m (55.4ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 903102,  Location: N.CTR-36-T24NR5W (Lat: 40.491203,  Lng: -89.616592),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 200 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 349 (year 2032),  Design Load: HS 15,  Features Intersected: LOST CREEK,  Facility Carried by Structure: TR-141 (FURROW RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.494,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.6m (41.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Fair,  Operating Rating: 41.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: January 2021,  Other Special Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 903184,  Location: NE-35-T24NR5W (Lat: 40.492319,  Lng: -89.626833),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 500 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 645 (year 2032),  Design Load: HS 20,  Features Intersected: LOST CREEK,  Facility Carried by Structure: 14TH ST - TR 76H
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.458,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 903185,  Location: SW-2-T23NR5W (Lat: 40.465436,  Lng: -89.640400),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 100 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 134 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: CHRISTMAS TREE-TR1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.720,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Very good,  Channel: Very good,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 90322,  Location: NE COR-36-T23NR5W (Lat: 40.494064,  Lng: -89.606394),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 2,500 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,795 (year 2032),  Design Load: HS 20,  Features Intersected: LOST CREEK,  Facility Carried by Structure: FAS 2462 - CH 11
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.136,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.3m (56.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 905,  Location: NW-2-T23NR5W (Lat: 40.480189,  Lng: -89.634911),  Route carried "on" structure: County highway ,  Year Built: 1956,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 1,800 (year 2018),  Truck Traffic: 9%,  Average Future Daily Traffic: 2,150 (year 2032),  Design Load: H 15,  Features Intersected: STREAM,  Facility Carried by Structure: CH-7 (FAS-1481)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.665,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.6m (18.4ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 25.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 15.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 905001,  Location: NE-1-T23NR5W (Lat: 40.480450,  Lng: -89.613994),  Route carried "on" structure: County highway ,  Year Built: 1956,  Status: Open,  Structure Length: 0.80m (2.62ft),  Average Daily Traffic: 1,800 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,311 (year 2032),  Design Load: H 15,  Features Intersected: STREAM,  Facility Carried by Structure: CH-7 (FAS-1481)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.452,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 13.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 905011,  Location: N.CTR-17-T23NR5W (Lat: 40.449681,  Lng: -89.691139),  Route carried "on" structure: County highway ,  Year Built: 1953,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 900 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 914 (year 2032),  Features Intersected: STREAM,  Facility Carried by Structure: TR 62A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.299,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 23.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 905018,  Location: SE-35-T24NR5W (Lat: 40.484389,  Lng: -89.625394),  Route carried "on" structure: County highway ,  Year Built: 1967,  Status: Posted for load,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 500 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 645 (year 2032),  Features Intersected: STREAM,  Facility Carried by Structure: TR 76H
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.359,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 17.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 10.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 905019,  Location: S.CTR-36-T24NR5W (Lat: 40.482158,  Lng: -89.615856),  Route carried "on" structure: County highway ,  Year Built: 1955,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 10 (year 2018),  Average Future Daily Traffic: 11 (year 2032),  Features Intersected: STREAM,  Facility Carried by Structure: TR 88
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.982,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 90502,  Location: NE-1-T23NR5W (Lat: 40.479217,  Lng: -89.609514),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 10 (year 2018),  Average Future Daily Traffic: 11 (year 2032),  Features Intersected: STREAM,  Facility Carried by Structure: TR 90
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.145,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss South Pekin, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.