U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Springdale, Wisconsin (WI) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Springdale, WI, Wisconsin, Wisconsin forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 20
Total length: 92 meters (302ft)
Total average daily traffic: 115,744
Total average daily truck traffic: 8,577
National Bridge Inventory (NBI) Registered Bridges for Springdale

New bridges - Historical Statistics

  • 1950-1959: 4
  • 1960-1969: 0
  • 1970-1979: 0
  • 1980-1989: 6
  • 1990-1999: 8
  • 2000-2009: 2

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Find on map >>

Structure Number: B130028,  Location: 0.2M S JCT STH 92 (Lat: 42.946056,  Lng: -89.657333),  Route carried "on" structure: County highway ,  Year Built: 1950,  Status: Open,  Structure Length: 2.08m (6.82ft),  Average Daily Traffic: 1,740 (year 2005),  Average Future Daily Traffic: 561 (year 2025),  Design Load: H 15,  Features Intersected: MT VERNON CREEK,  Facility Carried by Structure: CTH G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.8m (2.6ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: B130051,  Location: 2.9M E JCT CTH P (Lat: 42.988056,  Lng: -89.627328),  Route carried "on" structure: US 18,  Year Built: 1955,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 4.08m (13.39ft),  Average Daily Traffic: 9,300 (year 2006),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,640 (year 2023),  Design Load: H 20,  Features Intersected: CTH J
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B130109,  Location: 1.0M N JCT CTH PD (Lat: 43.024972,  Lng: -89.621611),  Route carried "on" structure: County highway ,  Year Built: 1958,  Status: Open,  Structure Length: 3.12m (10.24ft),  Average Daily Traffic: 430 (year 2005),  Average Future Daily Traffic: 165 (year 2022),  Design Load: H 15,  Features Intersected: SUGAR RIVER,  Facility Carried by Structure: CTH J
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: B130301,  Location: 1.5M W JCT CTH P (Lat: 42.997708,  Lng: -89.719647),  Route carried "on" structure: US 18,  Year Built: 1984,  Status: Open,  Structure Length: 4.03m (13.22ft),  Average Daily Traffic: 8,700 (year 2006),  Truck Traffic: 8%,  Average Future Daily Traffic: 22,820 (year 2023),  Design Load: HS 20,  Features Intersected: STH 92
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B130302,  Location: 0.8M E JCT CTH JG (Lat: 42.997256,  Lng: -89.719944),  Route carried "on" structure: US 18,  Year Built: 1988,  Status: Open,  Structure Length: 4.55m (14.93ft),  Average Daily Traffic: 8,600 (year 2006),  Truck Traffic: 8%,  Average Future Daily Traffic: 22,820 (year 2023),  Design Load: HS 20,  Features Intersected: STH 92
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B130303,  Location: AT JCT USH 18-USH 151 (Lat: 43.004708,  Lng: -89.702814),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 6.46m (21.19ft),  Average Daily Traffic: 2,630 (year 2006),  Average Future Daily Traffic: 9,900 (year 2026),  Design Load: HS 20,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: CTH ID
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.0m (105.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B130377,  Location: 3.5M N JCT STH 92 (Lat: 43.004822,  Lng: -89.691506),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 6.15m (20.18ft),  Average Daily Traffic: 290 (year 2005),  Average Future Daily Traffic: 290 (year 2026),  Design Load: HS 20,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: LRD TOWN HALL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.7m (104.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B130378,  Location: 0.3M S JCT HALLS RD (Lat: 43.003725,  Lng: -89.680822),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 140 (year 2005),  Average Future Daily Traffic: 140 (year 2025),  Design Load: HS 20,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: LRD LUNDE LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B130379,  Location: 2.4M W JCT CTH J TO S (Lat: 42.999356,  Lng: -89.668469),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 7.13m (23.39ft),  Average Daily Traffic: 2,500 (year 2005),  Average Future Daily Traffic: 3,430 (year 2026),  Design Load: HS 20,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: CTH PD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.9m (114.5ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B13038,  Location: 2.7M W JCT CTH G TO S (Lat: 42.988386,  Lng: -89.626839),  Route carried "on" structure: US 18,  Year Built: 1991,  Status: Open,  Structure Length: 4.16m (13.65ft),  Average Daily Traffic: 9,200 (year 2006),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,099 (year 2023),  Design Load: HS 20,  Features Intersected: CTH J
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B130567,  Location: AT BR. SUGAR RIVER (Lat: 42.972639,  Lng: -89.604139),  Route carried "on" structure: City street ,  Year Built: 2003,  Status: Open,  Structure Length: 0.93m (3.05ft),  Average Daily Traffic: 100 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 150 (year 2023),  Design Load: HS 20,  Features Intersected: BR SUGAR R,  Facility Carried by Structure: LRD SPRING ROSE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: B130568,  Location: 0.7M E JCT OF CTH J (Lat: 43.016861,  Lng: -89.610000),  Route carried "on" structure: City street ,  Year Built: 2004,  Status: Open,  Structure Length: 1.42m (4.66ft),  Average Daily Traffic: 100 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 150 (year 2023),  Design Load: HS 20,  Features Intersected: SUGAR RIVER,  Facility Carried by Structure: LRD PAULSON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: B130051,  Location: 1.6M N JCT CTH G (Lat: 42.988056,  Lng: -89.627328),  Route carried "under" structure: County highway ,  Year Built: 1955,  Structure Length: 4.08m (13.39ft),  Average Daily Traffic: 125 (year 2005),  Features Intersected: CTH J,  Facility Carried by Structure: USH 18 EB-USH 151
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>

Structure Number: B130301,  Location: 1.5M E JCT STH 78 (Lat: 42.997708,  Lng: -89.719647),  Route carried "under" structure: State highway 92,  Year Built: 1984,  Structure Length: 4.03m (13.22ft),  Average Daily Traffic: 2,100 (year 2005),  Truck Traffic: 7%,  Features Intersected: STH 92,  Facility Carried by Structure: USH 18 WB-USH 151
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.7m (58.1ft)

Find on map >>

Structure Number: B130302,  Location: 1.5M E JCT STH 78 (Lat: 42.997256,  Lng: -89.719944),  Route carried "under" structure: State highway 92,  Year Built: 1988,  Structure Length: 4.55m (14.93ft),  Average Daily Traffic: 2,100 (year 2005),  Truck Traffic: 7%,  Features Intersected: STH 92,  Facility Carried by Structure: USH 18 EB-USH 151
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.7m (58.1ft)

Find on map >>

Structure Number: B130303,  Location: 0.9M E JCT STH 92 (Lat: 43.004708,  Lng: -89.702814),  Route carried "under" structure: US 18,  Year Built: 1984,  Structure Length: 6.46m (21.19ft),  Average Daily Traffic: 16,780 (year 2005),  Truck Traffic: 8%,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: CTH ID
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>

Structure Number: B130377,  Location: 1.6M E JCT STH 92 (Lat: 43.004822,  Lng: -89.691506),  Route carried "under" structure: US 18,  Year Built: 1991,  Structure Length: 6.15m (20.18ft),  Average Daily Traffic: 16,780 (year 2005),  Truck Traffic: 8%,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: LRD TOWN HALL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.7m (104.0ft)

Find on map >>

Structure Number: B130378,  Location: 2.1M E JCT STH 92 (Lat: 43.003725,  Lng: -89.680822),  Route carried "under" structure: US 18,  Year Built: 1991,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 16,780 (year 2005),  Truck Traffic: 8%,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: LRD LUNDE LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>

Structure Number: B130379,  Location: 0.4M E JCT CTH P TO N (Lat: 42.999356,  Lng: -89.668469),  Route carried "under" structure: US 18,  Year Built: 1991,  Structure Length: 7.13m (23.39ft),  Average Daily Traffic: 17,289 (year 2005),  Truck Traffic: 8%,  Features Intersected: USH 18-USH 151,  Facility Carried by Structure: CTH PD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.9m (114.5ft)

Find on map >>

Structure Number: B13038,  Location: 1.7M N JCT CTH G (Lat: 42.988386,  Lng: -89.626839),  Route carried "under" structure: County highway ,  Year Built: 1991,  Structure Length: 4.16m (13.65ft),  Average Daily Traffic: 60 (year 2005),  Features Intersected: CTH J,  Facility Carried by Structure: USH 18 WB-USH 151
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Discuss this city on our hugely popular Wisconsin forum

Back to: Springdale, WI, Wisconsin, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.