Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Tioga, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 28Number of bridges
  • 915ft / 279mTotal length
  • $3,659,000Total costs
  • 83,933Total average daily traffic
  • 17,794Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Tioga
  • No street view available for this location

New bridges in Tioga, PA - historical statistics
  • New bridges - historical statistics
  • 31940-1949
  • 11960-1969
  • 91970-1979
  • 11980-1989
  • 21990-1999
  • 102000-2009
  • 12010-2019
  • 12020-2022
Average Bridge Daily Traffic in Tioga, PA
Average Bridge Truck Traffic in Tioga, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 21.7%Very good
  • 56.5%Good
  • 21.7%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 30.4%Very good
  • 43.5%Good
  • 17.4%Satisfactory
  • 4.3%Fair
  • 4.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 21.7%Very good
  • 60.9%Good
  • 17.4%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 47.4%Very good
  • 15.8%Good
  • 10.5%Satisfactory
  • 21.1%Fair
  • 5.3%Poor
Find on map >>   Show street view

Structure Number: 32803,  Location: MILL CRK/TIOGA DAM BRIDGE (Lat: 41.881958,  Lng: -77.126353),  Route carried "on" structure: US 15,  Year Built: 1974,  Status: Open,  Structure Length: 46.33m (152.00ft),  Average Daily Traffic: 5,723 (year 2022),  Truck Traffic: 26%,  Average Future Daily Traffic: 5,775 (year 2032),  Design Load: HS 20,  Features Intersected: OVER MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 41.606,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 57.6m (189.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 47.00m (154.20ft),  Designated Inspection Frequency: Every 48 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Underwater Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32804,  Location: 0.5 MI E OF TIOGA BORO (Lat: 41.911667,  Lng: -77.118333),  Route carried "on" structure: State highway ,  Year Built: 1974,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 82 (year 2022),  Truck Traffic: 9%,  Average Future Daily Traffic: 264 (year 2032),  Design Load: HS 20,  Features Intersected: SR 15,  Facility Carried by Structure: PARK HILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.1m (111.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 93.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 7.90m (25.92ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 32809,  Location: 2.5 MI N OF TIOGA BORO (Lat: 41.933167,  Lng: -77.108308),  Route carried "on" structure: State highway 287,  Year Built: 1948,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 3,740 (year 2022),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,866 (year 2032),  Design Load: HS 20,  Features Intersected: OVER MITCHELL CREEK,  Facility Carried by Structure: US TR 15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 51.993,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.90m (6.23ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 32811,  Location: 1 MI S TIOGA JUNCTION (Lat: 41.951494,  Lng: -77.105378),  Route carried "on" structure: State highway 287,  Year Built: 1942,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 3,740 (year 2022),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,866 (year 2032),  Features Intersected: OVER MUTTON LANE CREEK,  Facility Carried by Structure: SR 0015
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.074,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $11,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $153,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 32882,  Location: 1 MI S OF TIOGA BORO (Lat: 41.908869,  Lng: -77.157558),  Route carried "on" structure: State highway 287,  Year Built: 1975,  Status: Open,  Structure Length: 6.92m (22.70ft),  Average Daily Traffic: 2,142 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 4,948 (year 2032),  Design Load: HS 20,  Features Intersected: OVER CROOKED CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.807,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 87.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 6.90m (22.64ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Bridge Improvement Cost: $18,000,  Roadway Improvement Cost: $53,000,  Total Project Cost: $244,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32883,  Location: N.TIOGA BORO-RIVER BRIDGE (Lat: 41.922450,  Lng: -77.129950),  Route carried "on" structure: State highway 287,  Year Built: 1949,  Status: Open,  Structure Length: 10.79m (35.40ft),  Average Daily Traffic: 4,082 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,988 (year 2032),  Design Load: HL 93,  Features Intersected: OVER TIOGA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.585,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.6m (97.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 56.3 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 43.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 10.80m (35.43ft),  Designated Inspection Frequency: Every 9 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $73,000,  Roadway Improvement Cost: $214,000,  Total Project Cost: $981,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 32998,  Location: BOROUGH OF TIOGA (Lat: 41.910497,  Lng: -77.137350),  Route carried "on" structure: State highway ,  Year Built: 1974,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 548 (year 2022),  Truck Traffic: 15%,  Average Future Daily Traffic: 582 (year 2032),  Design Load: HS 20,  Features Intersected: OVER CROOKED CREEK,  Facility Carried by Structure: SR 1030
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.411,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.0m (82.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.00m (19.69ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Bridge Improvement Cost: $92,000,  Roadway Improvement Cost: $270,000,  Total Project Cost: $1,239,000,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 33194,  Location: 3.75 MI NW OF TIOGA BORO (Lat: 41.913578,  Lng: -77.193414),  Route carried "on" structure: State highway ,  Year Built: 1974,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 161 (year 2022),  Truck Traffic: 12%,  Average Future Daily Traffic: 465 (year 2032),  Design Load: HL 93,  Features Intersected: OVER ELKHORN CREEK,  Facility Carried by Structure: SR 4024
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.581,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.10m (3.61ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 33327,  Location: 2.5 MI. NE OF TIOGA BORO (Lat: 41.930119,  Lng: -77.096042),  Route carried "on" structure: City street ,  Year Built: 1962,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 150 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 232 (year 2043),  Design Load: HS 20,  Features Intersected: STEAM MILL CREEK,  Facility Carried by Structure: TIOGA TWP T-669
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 10.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 9.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Other Special Inspection Date: June 2021,  Bridge Improvement Cost: $6,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $81,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 33328,  Location: 1.6 MI NW OF TIOGA BORO (Lat: 41.928081,  Lng: -77.149436),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 75 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 116 (year 2043),  Design Load: HS 20,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: T-701 BEAR CREEK R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 33348,  Location: BOROUGH OF TIOGA (Lat: 41.908683,  Lng: -77.129217),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 8.32m (27.30ft),  Average Daily Traffic: 110 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 170 (year 2043),  Design Load: HS 20,  Features Intersected: TIOGA RIVER,  Facility Carried by Structure: T-667 CTY BR #12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 8.30m (27.23ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 33372,  Location: 1.6 MI NE OF TIOGA BORO (Lat: 41.931667,  Lng: -77.111667),  Route carried "on" structure: US 15,  Year Built: 1992,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 5,723 (year 2022),  Truck Traffic: 26%,  Average Future Daily Traffic: 5,775 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: old 15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.928,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.6m (97.1ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Inventory Rating: 95.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.20m (23.62ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Bridge Improvement Cost: $39,000,  Roadway Improvement Cost: $115,000,  Total Project Cost: $528,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4085,  Location: 1.5 miles East of Tioga (Lat: 41.921456,  Lng: -77.132489),  Route carried "on" structure: State highway ,  Year Built: 2000,  Status: Open,  Structure Length: 6.19m (20.31ft),  Average Daily Traffic: 280 (year 2022),  Truck Traffic: 6%,  Average Future Daily Traffic: 296 (year 2032),  Design Load: HL 93,  Features Intersected: OVER CROOKED CREEK,  Facility Carried by Structure: SR 1032
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.10m (23.29ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41534,  Location: MILL CREEK/TIOGA DAM/SB (Lat: 41.881806,  Lng: -77.126353),  Route carried "on" structure: US 15,  Year Built: 2001,  Status: Open,  Structure Length: 46.60m (152.89ft),  Average Daily Traffic: 5,605 (year 2022),  Truck Traffic: 26%,  Average Future Daily Traffic: 5,930 (year 2032),  Design Load: HS 20,  Features Intersected: TIOGA RESERVOIR, MILL CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 41.619,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 58.2m (190.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 47.30m (155.18ft),  Designated Inspection Frequency: Every 48 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Underwater Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 43263,  Location: .2 M W OF LAWRENCEVILLE (Lat: 41.931189,  Lng: -77.114444),  Route carried "on" structure: US 15,  Year Built: 2005,  Status: Open,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 3,846 (year 2021),  Truck Traffic: 33%,  Average Future Daily Traffic: 4,668 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: SR 49
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 55.384,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.3m (128.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 43264,  Location: .2 M W OF LAWRENCEVILLE (Lat: 41.931222,  Lng: -77.114567),  Route carried "on" structure: US 15,  Year Built: 2005,  Status: Open,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 4,520 (year 2021),  Truck Traffic: 22%,  Average Future Daily Traffic: 4,979 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: SR 49
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 55.408,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.3m (128.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 45155,  Location: 2 Mi N. OF TIOGA BORO (Lat: 41.937656,  Lng: -77.110842),  Route carried "on" structure: US 15,  Year Built: 2008,  Status: Open,  Structure Length: 51.72m (169.69ft),  Average Daily Traffic: 4,708 (year 2021),  Truck Traffic: 29%,  Average Future Daily Traffic: 6,390 (year 2032),  Design Load: HL 93,  Features Intersected: TIOGA RIVER AND RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.618,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 49.4m (162.1ft),  Curb or Sidewalk Widths: Left: 13.2m (43.3ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 92.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 45156,  Location: 2 MI. N. OF TIOGA BORO (Lat: 41.937439,  Lng: -77.111189),  Route carried "on" structure: US 15,  Year Built: 2008,  Status: Open,  Structure Length: 51.79m (169.91ft),  Average Daily Traffic: 4,961 (year 2021),  Truck Traffic: 29%,  Average Future Daily Traffic: 6,273 (year 2032),  Design Load: HL 93,  Features Intersected: TIOGA RIVER AND RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.626,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 49.1m (161.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 91.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 45161,  Location: 3 MI NORTH OF TIOGA BORO (Lat: 41.950706,  Lng: -77.117614),  Route carried "on" structure: US 15,  Year Built: 2008,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 4,708 (year 2021),  Truck Traffic: 29%,  Average Future Daily Traffic: 6,390 (year 2032),  Design Load: HL 93,  Features Intersected: UNNAMED TR TO TIOGA R.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.487,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.3m (106.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 45162,  Location: 3 MI. N. TIOGA BORO (Lat: 41.950575,  Lng: -77.117839),  Route carried "on" structure: US 15,  Year Built: 2008,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 4,961 (year 2021),  Truck Traffic: 29%,  Average Future Daily Traffic: 6,273 (year 2032),  Design Load: HL 93,  Features Intersected: UNNAMED TR. TO TIOGA RIV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.506,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.0m (95.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 48055,  Location: 3 MILES NORTHWEST OF TIOG (Lat: 41.912278,  Lng: -77.191014),  Route carried "on" structure: State highway ,  Year Built: 2013,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 161 (year 2022),  Truck Traffic: 12%,  Average Future Daily Traffic: 598 (year 2036),  Design Load: HL 93,  Features Intersected: ELKHORN CREEK,  Facility Carried by Structure: SR 4024 Elkhorn Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.909,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CEPNABPA-000003,  Location: TIOGA-HAMMOND LAKES (Lat: 41.881492,  Lng: -77.193097),  Route carried "on" structure: ServiceFederal lands road ,  Year Built: 1975,  Status: Posted for load,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 800 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 800 (year 2037),  Design Load: HS 20,  Features Intersected: Crooked Creek,  Facility Carried by Structure: MAIN ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 54.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 12.79m (41.96ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2021,  Underwater Inspection Date: June 2018,  Bridge Improvement Cost: $287,000,  Roadway Improvement Cost: $29,000,  Total Project Cost: $431,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: CEPNABPA-000028,  Location: 2.8 Mi NW Pickle Hill Rd. (Lat: 41.873775,  Lng: -77.101267),  Route carried "on" structure: Spur Federal lands road 1004,  Year Built: 2020,  Status: Open,  Structure Length: 0.92m (3.02ft),  Average Daily Traffic: 5 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 5 (year 2042),  Design Load: HL 93,  Features Intersected: Cabin Run,  Facility Carried by Structure: Mill Creek Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: Corps of Engineers (Civil),  Maintenance Responsibility: Private,  Approaching Roadway Width: 3.8m (12.5ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.6m (28.2ft),  Curb-To-Curb Width: 3.7m (12.1ft),  Out-to-Out Width: 4.3m (14.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.83m (6.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $1,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $2,000 ( Estimate for 2021),  Deck Structure Type: Wood or Timber
Find on map >>   Show street view

Structure Number: 32804,  Location: 0.5 MI E OF TIOGA BORO (Lat: 41.911667,  Lng: -77.118333),  Route carried "under" structure: US 15,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 5,605 (year 2022),  Truck Traffic: 26%,  Features Intersected: SR 15,  Facility Carried by Structure: PARK HILL RD
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 45.512,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 32804,  Location: 0.5 MI E OF TIOGA BORO (Lat: 41.911667,  Lng: -77.118333),  Route carried "under" structure: US 15,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 5,723 (year 2022),  Truck Traffic: 26%,  Features Intersected: SR 15,  Facility Carried by Structure: PARK HILL RD
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 45.474,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 33372,  Location: 1.6 MI NE OF TIOGA BORO (Lat: 41.931667,  Lng: -77.111667),  Route carried "under" structure: State highway 287,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 3,740 (year 2022),  Truck Traffic: 10%,  Features Intersected: old 15,  Facility Carried by Structure: SR 15 NBL
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 51.150,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 43263,  Location: .2 M W OF LAWRENCEVILLE (Lat: 41.931189,  Lng: -77.114444),  Route carried "under" structure: State highway 49,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 4,017 (year 2021),  Truck Traffic: 11%,  Features Intersected: SR 49,  Facility Carried by Structure: SR 15
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 42.841,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Find on map >>   Show street view

Structure Number: 43264,  Location: .2 M W OF LAWRENCEVILLE (Lat: 41.931222,  Lng: -77.114567),  Route carried "under" structure: State highway 49,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 4,017 (year 2021),  Truck Traffic: 11%,  Features Intersected: SR 49,  Facility Carried by Structure: SR 15 NB
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 42.841,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.3m (128.9ft)

Discuss Tioga, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.