National Bridge Inventory (NBI) Statistics
Number of bridges: 42
Total length: 469 meters (1,539ft)
Total costs: $4,060,000
Total average daily traffic: 2,622,498
Total average daily truck traffic: 220,086
National Bridge Inventory (NBI) Registered Bridges for Warrensville Heights

New bridges - Historical Statistics

  • 1950-1959: 3
  • 1960-1969: 5
  • 1970-1979: 29
  • 1980-1989: 1
  • 1990-1999: 4

Reconstructed bridges - Historical Statistics

  • 1980-1989: 1
  • 1990-1999: 8

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 1803484,  Location: APPROX .5 MI W NORTFIELD (Lat: 41.429619,  Lng: -81.536500),  Route carried "on" structure: County highway 4,  Year Built: 1959,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 37,282 (year 2002),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,572 (year 2027),  Design Load: H 20,  Features Intersected: SR-43 (MILES AVE)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.030,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.10m (20.01ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Bridge Improvement Cost: $770,000,  Roadway Improvement Cost: $90,000,  Total Project Cost: $860,000 ( Estimate for 2000),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1811088,  Location: JCT. I-271 WITH I-480N (Lat: 41.428700,  Lng: -81.507836),  Route carried "on" structure: Interstate 480N,  Year Built: 1972,  Status: Open,  Structure Length: 21.28m (69.82ft),  Average Daily Traffic: 113,930 (year 2004),  Truck Traffic: 11%,  Average Future Daily Traffic: 158,135 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: IR 271,422WB TO GO 271SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.080,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1811096,  Location: JCT. I-271 WITH I-480N (Lat: 41.433347,  Lng: -81.502914),  Route carried "on" structure: Ramp US 422,  Year Built: 1974,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 14.36m (47.11ft),  Average Daily Traffic: 56,435 (year 2000),  Truck Traffic: 9%,  Average Future Daily Traffic: 78,332 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: IR 271,  Facility Carried by Structure: I-480N W.B.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.740,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1811118,  Location: 1.38 MI. N. OF JCT. SR-43 (Lat: 41.433625,  Lng: -81.502681),  Route carried "on" structure: US 422,  Year Built: 1974,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 18.68m (61.29ft),  Average Daily Traffic: 15,430 (year 2004),  Truck Traffic: 3%,  Average Future Daily Traffic: 21,417 (year 2027),  Features Intersected: IR 271, 271X,  Facility Carried by Structure: RAMP NE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.700,  Lanes on structure: 1,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1811134,  Location: .16 MI. S. OF JCT. SR-175 (Lat: 41.435608,  Lng: -81.499664),  Route carried "on" structure: County highway 85,  Year Built: 1965,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 19.90m (65.29ft),  Average Daily Traffic: 35,502 (year 2002),  Truck Traffic: 4%,  Average Future Daily Traffic: 197,804 (year 2027),  Design Load: H 20,  Features Intersected: I-271,  Facility Carried by Structure: EMERY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 43.650,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 28.7m (94.2ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1811169,  Location: JCT. SR-175 WITH I-480 (Lat: 41.436072,  Lng: -81.497889),  Route carried "on" structure: State highway 175,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 25.38m (83.27ft),  Average Daily Traffic: 15,660 (year 2004),  Truck Traffic: 6%,  Average Future Daily Traffic: 21,736 (year 2027),  Design Load: H 20,  Features Intersected: IR 271,IR 480N TOGO 271B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.510,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 60.7m (199.1ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 23.59m (77.40ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2007,  Bridge Improvement Cost: $2,880,000,  Roadway Improvement Cost: $320,000,  Total Project Cost: $3,200,000 ( Estimate for 2000),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Membrane: Epoxy
Find on map >>

Structure Number: 1813625,  Location: .94 MI. W. OF JCT. SR-8 (Lat: 41.424794,  Lng: -81.545344),  Route carried "on" structure: City street CAMDN,  Year Built: 1971,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 1,000 (year 2002),  Average Future Daily Traffic: 240,027 (year 2027),  Design Load: H 15,  Features Intersected: IR 480,  Facility Carried by Structure: CAMDEN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.7m (94.2ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 27.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1813676,  Location: .52 MI. W. OF JCT. SR-8 (Lat: 41.424808,  Lng: -81.537206),  Route carried "on" structure: County highway 4,  Year Built: 1971,  Status: Open,  Structure Length: 8.99m (29.49ft),  Average Daily Traffic: 38,042 (year 2002),  Truck Traffic: 3%,  Average Future Daily Traffic: 237,788 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: I-480,  Facility Carried by Structure: WARRENSVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 77.300,  Lanes on structure: 6,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 27.6m (90.6ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1814494,  Location: JCT. SR-8 WITH I-480N (Lat: 41.424325,  Lng: -81.530536),  Route carried "on" structure: Interstate 480N,  Year Built: 1971,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 26.52m (87.01ft),  Average Daily Traffic: 117,300 (year 2004),  Truck Traffic: 11%,  Average Future Daily Traffic: 162,812 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: 8-0514 (NORTHFIELD),480W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.180,  Lanes on structure: 4,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 19 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 44.5m (146.0ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 181454,  Location: .65 MI. E. OF. JCT. SR-8 (Lat: 41.426017,  Lng: -81.517322),  Route carried "on" structure: Interstate 480N,  Year Built: 1974,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 56,965 (year 2004),  Truck Traffic: 11%,  Average Future Daily Traffic: 79,067 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: CR-14 (GREEN RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.220,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1814559,  Location: .65 MI. E. OF JCT. SR-8 (Lat: 41.426017,  Lng: -81.517322),  Route carried "on" structure: Interstate 480N,  Year Built: 1974,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 56,965 (year 2004),  Truck Traffic: 11%,  Average Future Daily Traffic: 79,067 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: CR-14 (GREEN RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.220,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 18.4m (60.4ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1814575,  Location: .43 MI. E. OF JCT. SR-8 (Lat: 41.424500,  Lng: -81.522358),  Route carried "on" structure: Interstate 480N,  Year Built: 1974,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 7.65m (25.10ft),  Average Daily Traffic: 115,461 (year 2004),  Truck Traffic: 11%,  Average Future Daily Traffic: 160,260 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: CR-11 (MILES RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.870,  Lanes on structure: 5,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Skew: 13 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 31.1m (102.0ft),  Out-to-Out Width: 32.3m (106.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1814591,  Location: AT 480N/422/271 INTERCHAN (Lat: 41.428967,  Lng: -81.506531),  Route carried "on" structure: Ramp Interstate 480N,  Year Built: 1997,  Status: Open,  Structure Length: 24.88m (81.63ft),  Average Daily Traffic: 112,870 (year 2000),  Truck Traffic: 9%,  Average Future Daily Traffic: 156,664 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: IR 271SB,IR 480N TOGO 42
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.190,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.7m (51.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1814613,  Location: 480N & 271 & 422 INTERCHG (Lat: 41.430117,  Lng: -81.504833),  Route carried "on" structure: Ramp Interstate 271X,  Year Built: 1998,  Status: Open,  Structure Length: 16.98m (55.71ft),  Average Daily Traffic: 112,870 (year 2000),  Truck Traffic: 9%,  Average Future Daily Traffic: 156,664 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: IR 271SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.350,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.7m (51.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 12 months,  Inspection Date: November 2007,  Critical Feature Inspection Date: January 1998,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1814664,  Location: 0.21M W RICHMOND RD (Lat: 41.431017,  Lng: -81.502875),  Route carried "on" structure: US 422,  Year Built: 1971,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 6,995 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 17,975 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: 422WB TOGO 480N WB/271SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.980,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 181468,  Location: .34 MI. E. OF I-271 (Lat: 41.431158,  Lng: -81.502986),  Route carried "on" structure: Ramp US 422,  Year Built: 1971,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 5.00m (16.40ft),  Average Daily Traffic: 13,440 (year 2001),  Truck Traffic: 6%,  Average Future Daily Traffic: 18,655 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: UP 422EB,DN 480N TOGO 27,  Facility Carried by Structure: I.R. 480N
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 21.960,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1814745,  Location: OVER SR 175 (Lat: 41.429603,  Lng: -81.497897),  Route carried "on" structure: US 422,  Year Built: 1971,  Status: Open,  Structure Length: 4.42m (14.50ft),  Average Daily Traffic: 6,995 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 9,709 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: SR 175 (RICHMOND RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.380,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 1814753,  Location: 0.4 MI. EAST OF JCT I-271 (Lat: 41.429128,  Lng: -81.505786),  Route carried "on" structure: Ramp Interstate 480N,  Year Built: 1971,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 6,475 (year 2000),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,987 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: SR 175 (RICHMOND RD),  Facility Carried by Structure: ROADWAY RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.250,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 1814788,  Location: 0.4 MI. EAST OF JCT I-271 (Lat: 41.429603,  Lng: -81.497897),  Route carried "on" structure: US 422,  Year Built: 1971,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 6,995 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 9,709 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: SR 175(02.35)RICHMOND RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.380,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place
Structure Number: 1831461,  Location: 1135' E OF NORTHFIELD RD,  Route carried "on" structure: County highway 85,  Year Built: 1974,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 22,669 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 22,474 (year 2023),  Design Load: HS 20,  Features Intersected: BEAR CREEK/EMERY RD #230
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.3 metric tons,  Inventory Rating: 24.3 metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Structure Number: 1834045,  Location: AT MILES RD,  Route carried "on" structure: County highway 4,  Year Built: 1957,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 44,589 (year 1999),  Truck Traffic: 3%,  Average Future Daily Traffic: 54,396 (year 2023),  Design Load: H 20,  Features Intersected: ERIE RR/WRRNSVLLE RD #20
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Operating Rating: 27.0 metric tons,  Inventory Rating: 19.8 metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Structure Number: 1834053,  Location: 464' SO OF HARVARD RD,  Route carried "on" structure: County highway 4,  Year Built: 1962,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 44,589 (year 1999),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,159 (year 2023),  Design Load: HS 20,  Features Intersected: MILL CRK/WARRENSVIL #221
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 33.3 metric tons,  Inventory Rating: 24.3 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 1801279,  Location: .25 MI S MILES RD (Lat: 41.424833,  Lng: -81.526892),  Route carried "under" structure: State highway 8,  Year Built: 1988,  Structure Length: 3.02m (9.91ft),  Average Daily Traffic: 30,130 (year 2004),  Truck Traffic: 3%,  Features Intersected: NSC RR S OF MILES,  Facility Carried by Structure: NSC RR
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 0.837,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>

Structure Number: 1803484,  Location: APPROX .5 MI W NORTFIELD (Lat: 41.429619,  Lng: -81.536500),  Route carried "under" structure: State highway 43,  Year Built: 1959,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 15,542 (year 2004),  Truck Traffic: 3%,  Features Intersected: CR 4(WARRENSVILLE CNTR R
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 1.517,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>

Structure Number: 1811088,  Location: JCT. I-271 WITH I-480N (Lat: 41.428700,  Lng: -81.507836),  Route carried "under" structure: Interstate 271,  Year Built: 1972,  Structure Length: 21.28m (69.82ft),  Average Daily Traffic: 142,510 (year 2004),  Truck Traffic: 8%,  Features Intersected: I480N EB,  Facility Carried by Structure: I-480N E.B.
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.895,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>

Structure Number: 1811096,  Location: JCT. I-271 WITH I-480N (Lat: 41.433347,  Lng: -81.502914),  Route carried "under" structure: Interstate 271,  Year Built: 1974,  Structure Length: 14.36m (47.11ft),  Average Daily Traffic: 142,510 (year 2004),  Truck Traffic: 8%,  Features Intersected: 422WB TOGO 480N WB,271SB,  Facility Carried by Structure: I-480N W.B.
Minimum Vertical Clearance: 0.61m (2.00ft),  Kilometerpoint: 0.906,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>

Structure Number: 1811118,  Location: 1.38 MI. N. OF JCT. SR-43 (Lat: 41.433625,  Lng: -81.502681),  Route carried "under" structure: Interstate 271,  Year Built: 1974,  Structure Length: 18.68m (61.29ft),  Average Daily Traffic: 142,510 (year 2004),  Truck Traffic: 8%,  Features Intersected: US 422 EB,  Facility Carried by Structure: RAMP NE
Minimum Vertical Clearance: 0.61m (2.00ft),  Kilometerpoint: 0.935,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>

Structure Number: 1811134,  Location: .16 MI. S. OF JCT. SR-175 (Lat: 41.435608,  Lng: -81.499664),  Route carried "under" structure: Interstate 271,  Year Built: 1965,  Structure Length: 19.90m (65.29ft),  Average Daily Traffic: 142,510 (year 2004),  Truck Traffic: 8%,  Features Intersected: CR-85 (EMERY RD),  Facility Carried by Structure: EMERY RD
Minimum Vertical Clearance: 5.92m (19.42ft),  Kilometerpoint: 0.982,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.7m (94.2ft)

Find on map >>

Structure Number: 1811169,  Location: JCT. SR-175 WITH I-480 (Lat: 41.436072,  Lng: -81.497889),  Route carried "under" structure: Interstate 271,  Year Built: 1965,  Structure Length: 25.38m (83.27ft),  Average Daily Traffic: 151,230 (year 2004),  Truck Traffic: 8%,  Features Intersected: SR-175 (RICHMOND RD),  Facility Carried by Structure: SR-175 RICHMOND RD
Minimum Vertical Clearance: 0.50m (1.64ft),  Kilometerpoint: 1.008,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 60.7m (199.1ft)

Find on map >>

Structure Number: 1813625,  Location: .94 MI. W. OF JCT. SR-8 (Lat: 41.424794,  Lng: -81.545344),  Route carried "under" structure: Interstate 480,  Year Built: 1971,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 172,930 (year 2004),  Truck Traffic: 10%,  Features Intersected: CAMDEN RD,  Facility Carried by Structure: CAMDEN RD
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 3.774,  Lanes on structure: 2,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.7m (94.2ft)

Find on map >>

Structure Number: 1813676,  Location: .52 MI. W. OF JCT. SR-8 (Lat: 41.424808,  Lng: -81.537206),  Route carried "under" structure: Interstate 480,  Year Built: 1971,  Structure Length: 8.99m (29.49ft),  Average Daily Traffic: 171,317 (year 2004),  Truck Traffic: 10%,  Features Intersected: CR-4 (WARRENSVILLE CNT),  Facility Carried by Structure: WARRENSVILLE RD
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 3.841,  Lanes on structure: 6,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>

Structure Number: 1814494,  Location: JCT. SR-8 WITH I-480N (Lat: 41.424325,  Lng: -81.530536),  Route carried "under" structure: Interstate 480,  Year Built: 1971,  Structure Length: 26.52m (87.01ft),  Average Daily Traffic: 26,620 (year 2004),  Truck Traffic: 8%,  Features Intersected: I-480N (CUY-480N-0011)
Minimum Vertical Clearance: 0.50m (1.64ft),  Kilometerpoint: 0.392,  Lanes on structure: 4,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 44.5m (146.0ft)

Find on map >>

Structure Number: 181454,  Location: .65 MI. E. OF. JCT. SR-8 (Lat: 41.426017,  Lng: -81.517322),  Route carried "under" structure: County highway 14,  Year Built: 1974,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 1,000 (year 1973),  Features Intersected: I-480N,  Facility Carried by Structure: I-480N W.B.
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 7.731,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>

Structure Number: 1814559,  Location: .65 MI. E. OF JCT. SR-8 (Lat: 41.426017,  Lng: -81.517322),  Route carried "under" structure: County highway 14,  Year Built: 1974,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 1,000 (year 1973),  Features Intersected: I-480N,  Facility Carried by Structure: I-480N E.B.
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 0.773,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>

Structure Number: 1814575,  Location: .43 MI. E. OF JCT. SR-8 (Lat: 41.424500,  Lng: -81.522358),  Route carried "under" structure: City street 11,  Year Built: 1974,  Structure Length: 7.65m (25.10ft),  Average Daily Traffic: 1,000 (year 1973),  Features Intersected: I-480N,  Facility Carried by Structure: I-480N
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.773,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.8m (78.1ft)

Find on map >>

Structure Number: 1814591,  Location: AT 480N/422/271 INTERCHAN (Lat: 41.428967,  Lng: -81.506531),  Route carried "under" structure: Interstate 271,  Year Built: 1997,  Structure Length: 24.88m (81.63ft),  Average Daily Traffic: 142,510 (year 2004),  Truck Traffic: 8%,  Features Intersected: IR480N EB TOGO IR271X NB
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.911,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>

Structure Number: 1814613,  Location: 480N & 271 & 422 INTERCHG (Lat: 41.430117,  Lng: -81.504833),  Route carried "under" structure: Interstate 271,  Year Built: 1998,  Structure Length: 16.98m (55.71ft),  Average Daily Traffic: 142,510 (year 2004),  Truck Traffic: 8%,  Features Intersected: IR 480N FROM IR 271B SB
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.091,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>

Structure Number: 1814664,  Location: 0.21M W RICHMOND RD (Lat: 41.431017,  Lng: -81.502875),  Route carried "under" structure: Ramp US 422,  Year Built: 1971,  Structure Length: 8.23m (27.00ft),  Features Intersected: US 422 EB
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 2.196,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>

Structure Number: 181468,  Location: .34 MI. E. OF I-271 (Lat: 41.431158,  Lng: -81.502986),  Route carried "under" structure: Interstate 480N,  Year Built: 1971,  Structure Length: 5.00m (16.40ft),  Average Daily Traffic: 113,930 (year 2004),  Truck Traffic: 11%,  Features Intersected: US-422
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 0.264,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.6m (61.0ft)

Find on map >>

Structure Number: 1814745,  Location: OVER SR 175 (Lat: 41.429603,  Lng: -81.497897),  Route carried "under" structure: State highway 175,  Year Built: 1971,  Structure Length: 4.42m (14.50ft),  Average Daily Traffic: 14,760 (year 2004),  Truck Traffic: 6%,  Features Intersected: I-271SB RAMP TO 422F EB,  Facility Carried by Structure: US 422
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.375,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>

Structure Number: 1814753,  Location: 0.4 MI. EAST OF JCT I-271 (Lat: 41.429128,  Lng: -81.505786),  Route carried "under" structure: State highway 175,  Year Built: 1971,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 14,760 (year 2004),  Truck Traffic: 6%,  Features Intersected: US 422 EB,  Facility Carried by Structure: ROADWAY RAMP
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 0.374,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>

Structure Number: 1814788,  Location: 0.4 MI. EAST OF JCT I-271 (Lat: 41.429603,  Lng: -81.497897),  Route carried "under" structure: State highway 175,  Year Built: 1971,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 14,760 (year 2004),  Truck Traffic: 6%,  Features Intersected: US 422 WB,  Facility Carried by Structure: U.S.R. 422
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 0.378,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Discuss this city on our hugely popular Ohio forum

Back to: Warrensville Heights, OH, Ohio, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.