Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Woodbridge, Connecticut (CT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 11Number of bridges
  • 105ft / 31.7mTotal length
  • 224,687Total average daily traffic
  • 9,413Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Woodbridge
  • No street view available for this location

New bridges in Woodbridge, CT - historical statistics
  • New bridges - historical statistics
  • 61940-1949
  • 11950-1959
  • 11980-1989
  • 31990-1999
Reconstructed bridges in Woodbridge, CT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 01990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Woodbridge, CT
Average Bridge Truck Traffic in Woodbridge, CT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 16.7%Very good
  • 66.7%Good
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Very good
  • 37.5%Good
  • 25.0%Satisfactory
  • 12.5%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 62.5%Good
  • 37.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 28.6%Good
  • 42.9%Satisfactory
  • 28.6%Fair
Find on map >>   Show street view

Structure Number: 286,  Location: 0.2 MILE NORTH OF RTE 12 (Lat: 41.589564,  Lng: -71.986689),  Route carried "on" structure: Interstate 395,  Year Built: 1958,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 18.23m (59.81ft),  Average Daily Traffic: 39,800 (year 2017),  Truck Traffic: 16%,  Average Future Daily Traffic: 59,139 (year 2037),  Design Load: H 20,  Features Intersected: QUINEBAUG RV & P&W RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.343,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.1m (79.1ft),  Skew: 22 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 24.2m (79.4ft),  Curb-To-Curb Width: 24.1m (79.1ft),  Out-to-Out Width: 32.5m (106.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 86.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: November 2019,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 492,  Location: 0.3 MI EAST CHAPLIN T.L. (Lat: 41.769247,  Lng: -72.090444),  Route carried "on" structure: US 6,  Year Built: 1948,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 8,900 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 13,225 (year 2039),  Design Load: HS 20,  Features Intersected: MERRICK BROOK AND TRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 159.776,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.8m (2.6ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 67.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 768,  Location: 0.9 MI N OF ROUTE 34 (Lat: 41.313644,  Lng: -73.021492),  Route carried "on" structure: State highway 114,  Year Built: 1949,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 8,800 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,076 (year 2036),  Features Intersected: ROUTE 15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.407,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 769,  Location: 1.1 MI N OF ROUTE 114 (Lat: 41.319342,  Lng: -73.001389),  Route carried "on" structure: City street ,  Year Built: 1949,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 1,842 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,737 (year 2040),  Features Intersected: ROUTE 15,  Facility Carried by Structure: JOHNSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.740,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 2638,  Location: 1.1 MI N OF ROUTE 243 (Lat: 41.344017,  Lng: -73.026728),  Route carried "on" structure: State highway 114,  Year Built: 1996,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 7,200 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,698 (year 2035),  Features Intersected: WEPAWAUG RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.835,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 286,  Location: 0.6 MILE WEST ROUTE 313 (Lat: 41.331350,  Lng: -73.006222),  Route carried "on" structure: State highway 243,  Year Built: 1996,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 3,700 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,498 (year 2035),  Design Load: HL 93,  Features Intersected: RACE BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.743,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 492,  Location: 100 FT E OF ROUTE 69 (Lat: 41.341103,  Lng: -72.977214),  Route carried "on" structure: City street ,  Year Built: 1940,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 1,208 (year 2010),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,795 (year 2030),  Design Load: HL 93,  Features Intersected: WEST RIVER,  Facility Carried by Structure: MERRITT AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.9m (52.2ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4921,  Location: 100 FT E OF ROUTE 69 (Lat: 41.344444,  Lng: -72.978922),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 3,537 (year 2010),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,256 (year 2030),  Design Load: HS 20,  Features Intersected: WEST RIVER,  Facility Carried by Structure: BRADLEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.370,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Fair,  Operating Rating: 67.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5699,  Location: 2.8 MI N OF ROUTE 15 (Lat: 41.377103,  Lng: -72.976800),  Route carried "on" structure: State highway 69,  Year Built: 1988,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 6,900 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,253 (year 2038),  Design Load: HS 20,  Features Intersected: SARGENT RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.957,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 768,  Location: 0.9 MI N OF ROUTE 34 (Lat: 41.313644,  Lng: -73.021492),  Route carried "under" structure: State highway 15,  Year Built: 1949,  Structure Length: 0. m,  Average Daily Traffic: 71,400 (year 2015),  Truck Traffic: 1%,  Features Intersected: ROUTE 15,  Facility Carried by Structure: ROUTE 114
Minimum Vertical Clearance: 4.32m (14.17ft),  Kilometerpoint: 70.344,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Frame,  Length of Maximum Span: 11.3m (37.1ft)

Find on map >>   Show street view

Structure Number: 769,  Location: 1.1 MI N OF ROUTE 114 (Lat: 41.319342,  Lng: -73.001389),  Route carried "under" structure: State highway 15,  Year Built: 1949,  Structure Length: 0. m,  Average Daily Traffic: 71,400 (year 2015),  Truck Traffic: 1%,  Features Intersected: ROUTE 15,  Facility Carried by Structure: JOHNSON ROAD
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 72.147,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Length of Maximum Span: 13.7m (44.9ft)