Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Clayton, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 73Number of bridges
  • 850ft / 259mTotal length
  • 877,640Total average daily traffic
  • 97,136Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Clayton
  • No street view available for this location

New bridges in Clayton, NC - historical statistics
  • New bridges - historical statistics
  • 21940-1949
  • 21950-1959
  • 81960-1969
  • 41970-1979
  • 61980-1989
  • 81990-1999
  • 312000-2009
  • 42010-2019
  • 82020-2022
Average Bridge Daily Traffic in Clayton, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.3%Very good
  • 63.2%Good
  • 28.9%Satisfactory
  • 2.6%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.6%Excellent
  • 34.2%Very good
  • 31.6%Good
  • 15.8%Satisfactory
  • 13.2%Fair
  • 2.6%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 28.9%Very good
  • 26.3%Good
  • 21.1%Satisfactory
  • 15.8%Fair
  • 7.9%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 63.9%Good
  • 30.6%Satisfactory
  • 5.6%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 7.7%Very good
  • 30.8%Good
  • 38.5%Satisfactory
  • 15.4%Fair
  • 7.7%Poor
Find on map >>   Show street view

Structure Number: 1010599,  Location: .93 M. NORTH.JCT.NC42 (Lat: 35.629886,  Lng: -78.536158),  Route carried "on" structure: State highway 1525,  Year Built: 2007,  Status: Open,  Structure Length: 7.95m (26.08ft),  Average Daily Traffic: 12,500 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 25,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US70 BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 45.4m (149.0ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010602,  Location: 1.6MI.E. OF JCT.SR1560 (Lat: 35.604214,  Lng: -78.438044),  Route carried "on" structure: Bypass US 70,  Year Built: 2008,  Status: Open,  Structure Length: 3.16m (10.37ft),  Average Daily Traffic: 12,000 (year 2011),  Truck Traffic: 14%,  Average Future Daily Traffic: 24,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1563
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.1m (98.8ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010606,  Location: 1.3 MI. E. JCT. SR1553 (Lat: 35.603511,  Lng: -78.415628),  Route carried "on" structure: Ramp US 70,  Year Built: 2008,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 5,000 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 10,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US70BUS.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.3m (46.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of corrective action,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 101062,  Location: 0.01 MI. W. JCT. SR2307 (Lat: 35.491500,  Lng: -78.270361),  Route carried "on" structure: Business US 7,  Year Built: 2017,  Status: Open,  Structure Length: 9.08m (29.79ft),  Average Daily Traffic: 8,100 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 16,200 (year 2040),  Design Load: HL 93,  Features Intersected: US70BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 9,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 24 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 44.5m (146.0ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Very good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010622,  Location: 0.4 MI. N. JCT. SR1913 (Lat: 35.613056,  Lng: -78.403611),  Route carried "on" structure: State highway 2850,  Year Built: 2018,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 700 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,400 (year 2040),  Design Load: HL 93,  Features Intersected: NCRR/NORFOLK OUTHERN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010652,  Location: 0.5 MI. E. JCT. SR1010 (Lat: 35.606844,  Lng: -78.564144),  Route carried "on" structure: State highway 42,  Year Built: 2022,  Status: Closed,  Structure Length: 8.59m (28.18ft),  Average Daily Traffic: 33,000 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 66,000 (year 2040),  Design Load: HL 93,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 18.5m (60.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 42.0m (137.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 18.6m (61.0ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 83.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1010775,  Location: 1.49 MI. W. JCT. SR1003 (Lat: 35.650000,  Lng: -78.371139),  Route carried "on" structure: State highway 42,  Year Built: 2020,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 26,000 (year 2040),  Design Load: HL 93,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 69.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 101001,  Location: JCT. OF US70 & NC42E (Lat: 35.645567,  Lng: -78.462672),  Route carried "under" structure: State highway 42,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 17,500 (year 2019),  Truck Traffic: 6%,  Features Intersected: US70E
Minimum Vertical Clearance: 4.54m (14.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 1010012,  Location: JCT. US70 & NC42 WBL (Lat: 35.645681,  Lng: -78.462553),  Route carried "under" structure: State highway 42,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 17,500 (year 2019),  Truck Traffic: 6%,  Features Intersected: US70W
Minimum Vertical Clearance: 4.41m (14.47ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 10105,  Location: 0.85 MI .E. JCT. NC42 (Lat: 35.598108,  Lng: -78.565039),  Route carried "under" structure: Interstate 40,  Year Built: 2021,  Structure Length: 0. m,  Average Daily Traffic: 32,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1010
Minimum Vertical Clearance: 0.00m,  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.6m (152.9ft)

Find on map >>   Show street view

Structure Number: 10105,  Location: 0.85 MI .E. JCT. NC42 (Lat: 35.598108,  Lng: -78.565039),  Route carried "under" structure: Interstate 40,  Year Built: 2021,  Structure Length: 0. m,  Average Daily Traffic: 32,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1010
Minimum Vertical Clearance: 0.00m,  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.6m (152.9ft)

Find on map >>   Show street view

Structure Number: 1010501,  Location: 0.6 MI.E. JCT.SR1010 (Lat: 35.606969,  Lng: -78.564253),  Route carried "under" structure: Interstate 40,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 32,500 (year 2018),  Truck Traffic: 16%,  Features Intersected: NC42
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 95.190,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Channel Beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 1010501,  Location: 0.6 MI.E. JCT.SR1010 (Lat: 35.606969,  Lng: -78.564253),  Route carried "under" structure: Interstate 40,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 32,500 (year 2018),  Truck Traffic: 16%,  Features Intersected: NC42
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 95.190,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Channel Beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 1010581,  Location: 2.79M. W. JCT. SR1560 (Lat: 35.623642,  Lng: -78.510436),  Route carried "under" structure: Bypass US 70,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: NC42
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.2m (118.8ft)

Find on map >>   Show street view

Structure Number: 1010581,  Location: 2.79M. W. JCT. SR1560 (Lat: 35.623642,  Lng: -78.510436),  Route carried "under" structure: Bypass US 70,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: NC42
Minimum Vertical Clearance: 5.53m (18.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.2m (118.8ft)

Find on map >>   Show street view

Structure Number: 1010582,  Location: 0.6 MI. S. JCT. SR1552 (Lat: 35.621111,  Lng: -78.496350),  Route carried "under" structure: Bypass US 70,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2019),  Truck Traffic: 12%,  Features Intersected: SR1554
Minimum Vertical Clearance: 6.60m (21.65ft),  Kilometerpoint: 97.933,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 1010582,  Location: 0.6 MI. S. JCT. SR1552 (Lat: 35.621111,  Lng: -78.496350),  Route carried "under" structure: Bypass US 70,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2019),  Truck Traffic: 12%,  Features Intersected: SR1554
Minimum Vertical Clearance: 6.47m (21.23ft),  Kilometerpoint: 97.933,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 1010583,  Location: 1.6 MI.E. OF JCT.NC42 (Lat: 35.616744,  Lng: -78.483478),  Route carried "under" structure: State highway 1555,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 4,700 (year 2012),  Truck Traffic: 7%,  Features Intersected: US70 BYP WBL
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.3m (115.8ft)

Find on map >>   Show street view

Structure Number: 1010584,  Location: 1.6 MI.E. OF JCT.NC42 (Lat: 35.616450,  Lng: -78.483497),  Route carried "under" structure: State highway 1555,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 5,100 (year 2016),  Truck Traffic: 7%,  Features Intersected: US70E.BYP
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 1010585,  Location: 1.3 MI.E. OF JCT.SR1554 (Lat: 35.611906,  Lng: -78.463006),  Route carried "under" structure: State highway 1560,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2018),  Truck Traffic: 7%,  Features Intersected: US70 BYP WBL
Minimum Vertical Clearance: 6.32m (20.73ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 1010586,  Location: 1.3 MI.E. JCT. SR1554 (Lat: 35.611694,  Lng: -78.463292),  Route carried "under" structure: State highway 1560,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 2018),  Features Intersected: US70 BYP EBL
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 1010599,  Location: .93 M. NORTH.JCT.NC42 (Lat: 35.629886,  Lng: -78.536158),  Route carried "under" structure: Bypass US 70,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 16,250 (year 2019),  Truck Traffic: 12%,  Features Intersected: SR1525
Minimum Vertical Clearance: 6.09m (19.98ft),  Kilometerpoint: 97.232,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.4m (149.0ft)

Find on map >>   Show street view

Structure Number: 1010599,  Location: .93 M. NORTH.JCT.NC42 (Lat: 35.629886,  Lng: -78.536158),  Route carried "under" structure: Bypass US 70,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 16,250 (year 2019),  Truck Traffic: 12%,  Features Intersected: SR1525
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 97.232,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.4m (149.0ft)

Find on map >>   Show street view

Structure Number: 1010602,  Location: 1.6MI.E. OF JCT.SR1560 (Lat: 35.604214,  Lng: -78.438044),  Route carried "under" structure: State highway 1563,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 3,400 (year 2017),  Truck Traffic: 7%,  Features Intersected: US70BYP WBL
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 1010606,  Location: 1.3 MI. E. JCT. SR1553 (Lat: 35.603511,  Lng: -78.415628),  Route carried "under" structure: Business US 70,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: US70W.RAMP
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 1010606,  Location: 1.3 MI. E. JCT. SR1553 (Lat: 35.603511,  Lng: -78.415628),  Route carried "under" structure: Business US 70,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: US70W.RAMP
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 1010652,  Location: 0.5 MI. E. JCT. SR1010 (Lat: 35.606844,  Lng: -78.564144),  Route carried "under" structure: Interstate 40,  Year Built: 2022,  Structure Length: 0. m,  Average Daily Traffic: 30,000 (year 2018),  Truck Traffic: 16%,  Features Intersected: NC42(CLOSED)
Minimum Vertical Clearance: 6.61m (21.69ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.0m (137.8ft)

Find on map >>   Show street view

Structure Number: 1010652,  Location: 0.5 MI. E. JCT. SR1010 (Lat: 35.606844,  Lng: -78.564144),  Route carried "under" structure: Interstate 40,  Year Built: 2022,  Structure Length: 0. m,  Average Daily Traffic: 30,000 (year 2018),  Truck Traffic: 16%,  Features Intersected: NC42(CLOSED)
Minimum Vertical Clearance: 6.21m (20.37ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.0m (137.8ft)

Find on map >>   Show street view

Structure Number: 1010652,  Location: 0.5 MI. E. JCT. SR1010 (Lat: 35.606844,  Lng: -78.564144),  Route carried "under" structure: Interstate 40,  Year Built: 2022,  Structure Length: 0. m,  Average Daily Traffic: 30,000 (year 2018),  Truck Traffic: 16%,  Features Intersected: NC42(CLOSED)
Minimum Vertical Clearance: 6.61m (21.69ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.0m (137.8ft)

Discuss Clayton, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.