Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for East Brunswick, New Jersey (NJ)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 59Number of bridges
  • 787ft / 240mTotal length
  • $19,342,000Total costs
  • 2,211,995Total average daily traffic
  • 259,942Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for East Brunswick
  • No street view available for this location

New bridges in East Brunswick, NJ - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 41950-1959
  • 71960-1969
  • 101970-1979
  • 61980-1989
  • 271990-1999
  • 22000-2009
  • 22010-2019
Reconstructed bridges in East Brunswick, NJ - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21980-1989
  • 11990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in East Brunswick, NJ
Average Bridge Truck Traffic in East Brunswick, NJ
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.3%Very good
  • 70.0%Good
  • 16.7%Satisfactory
  • 10.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 10.0%Very good
  • 36.7%Good
  • 40.0%Satisfactory
  • 13.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 3.3%Very good
  • 33.3%Good
  • 50.0%Satisfactory
  • 13.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 21.1%Excellent
  • 21.1%Very good
  • 26.3%Good
  • 15.8%Satisfactory
  • 15.8%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 88.9%Satisfactory
  • 11.1%Fair
Find on map >>   Show street view

Structure Number: 1212151,  Location: 2.5 MILES SOUTH OF NJ TPK (Lat: 40.439581,  Lng: -74.393689),  Route carried "on" structure: County highway 535,  Year Built: 1963,  Status: Open,  Structure Length: 5.00m (16.40ft),  Average Daily Traffic: 22,596 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 27,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NEW JERSEY ROUTE 18
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 41.392,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.8m (78.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1212152,  Location: .2 MILES NORTH OF 535 JCT (Lat: 40.442239,  Lng: -74.394861),  Route carried "on" structure: County highway 606,  Year Built: 1963,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 15,846 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 19,015 (year 2041),  Design Load: HS 20,  Features Intersected: ROUTE NJ 18,  Facility Carried by Structure: MILLTOWN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.451,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.8m (78.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1212153,  Location: 2.0 MI S OF NJTPK JCT (Lat: 40.443911,  Lng: -74.395011),  Route carried "on" structure: State highway 18,  Year Built: 1931,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 33,900 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 40,680 (year 2040),  Features Intersected: CONRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.286,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.6m (64.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 87.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1212154,  Location: 2.12 MI S OF NJTPK JCT (Lat: 40.444239,  Lng: -74.395469),  Route carried "on" structure: State highway 18,  Year Built: 1963,  Status: Open,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 32,660 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 39,192 (year 2040),  Design Load: HS 20,  Features Intersected: CONRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.286,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 123B078,  Location: 0.06 miles north of CR677 (Lat: 40.416481,  Lng: -74.361700),  Route carried "on" structure: County highway 615,  Year Built: 2008,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 10,989 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,409 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SOUTH RIVER,  Facility Carried by Structure: BORDENTOWN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.019,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Inventory Rating: 73.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2021,  Underwater Inspection Date: August 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 123B135,  Location: 2.3 MI. E. OF NJ TURNPIKE (Lat: 40.408700,  Lng: -74.430950),  Route carried "on" structure: City street ,  Year Built: 1987,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 3,787 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,621 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: IRELAND BROOK,  Facility Carried by Structure: FERN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.706,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 123B144,  Location: 2.0 MI N OF ROUTE 130 (Lat: 40.429639,  Lng: -74.468561),  Route carried "on" structure: City street ,  Year Built: 1962,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 3,630 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,430 (year 2039),  Features Intersected: BEAVERDAM BROOK,  Facility Carried by Structure: RIVA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.966,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 123B152,  Location: 1 MI S OF US 1 (Lat: 40.458431,  Lng: -74.425119),  Route carried "on" structure: County highway 617,  Year Built: 2009,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 26,025 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 31,755 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SAWMILL BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.771,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 23.8m (78.1ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 27.4m (89.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 123B156,  Location: 0.6 MI WEST OF RT 18 (Lat: 40.453461,  Lng: -74.414131),  Route carried "on" structure: City street ,  Year Built: 1967,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 14,595 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 17,805 (year 2041),  Features Intersected: TRIB. LAWRENCE BROOK,  Facility Carried by Structure: TICES LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.221,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.8m (19.0ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 123B2,  Location: 0.1 S. JCT RUES LANE (Lat: 40.416581,  Lng: -74.413250),  Route carried "on" structure: County highway 535,  Year Built: 1981,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 5,805 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 7,085 (year 2041),  Design Load: HS 20,  Features Intersected: IRELAND BROOK,  Facility Carried by Structure: CRANBURY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 37.997,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 25 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.8m (5.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 123B231,  Location: 1.08 miles west of CR527 (Lat: 40.440719,  Lng: -74.409319),  Route carried "on" structure: County highway 606,  Year Built: 1997,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 15,847 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 19,333 (year 2041),  Features Intersected: SAWMILL BROOK,  Facility Carried by Structure: MILLTOWN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.738,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 123B232,  Location: 0.4 miles North of CR606 (Lat: 40.446719,  Lng: -74.409350),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 449 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 548 (year 2041),  Design Load: HS 20,  Features Intersected: SAWMILL BROOK,  Facility Carried by Structure: KIMBERLY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2021,  Underwater Inspection Date: June 2019
Find on map >>   Show street view

Structure Number: 123B233,  Location: 0.6 miles North of CR606 (Lat: 40.449939,  Lng: -74.409239),  Route carried "on" structure: City street ,  Year Built: 1998,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 7 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 9 (year 2041),  Features Intersected: SAWMILL BROOK,  Facility Carried by Structure: MILLBROOK COURT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 124B027,  Location: 1.1 MI EAST OF US 130 (Lat: 40.424200,  Lng: -74.477811),  Route carried "on" structure: County highway 694,  Year Built: 1986,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 6,724 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 8,203 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: FARRINGTON LAKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.287,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: May 2021,  Underwater Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 124B058,  Location: 0.2 MILE EAST OF NJTPK (Lat: 40.406719,  Lng: -74.446500),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 4,070 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,970 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: IRELAND BROOK TRIBUTARY,  Facility Carried by Structure: DUNHAMS CORNER RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.786,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 60.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: I08334C,  Location: .05 MI N INTERCHANGE 9 (Lat: 40.478450,  Lng: -74.410264),  Route carried "on" structure: City street ,  Year Built: 1988,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 1.80m (5.91ft),  Average Daily Traffic: 5,223 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,373 (year 2041),  Design Load: HS 20,  Features Intersected: NJ TPK INT.9 RAMP TW,  Facility Carried by Structure: NARICON PLACE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Owner: State Toll Authority,  Approaching Roadway Width: 31.5m (103.3ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 27.8m (91.2ft),  Out-to-Out Width: 31.5m (103.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 95.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 73.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: I8334BR,  Location: 0.6 MI S OF US 1 (Lat: 40.477778,  Lng: -74.410167),  Route carried "on" structure: State highway 18,  Year Built: 2015,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 107,655 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 129,186 (year 2041),  Design Load: HL 93,  Features Intersected: INT. 9 RAMPS TE & WT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 64.277,  Lanes on structure: 9,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 40.5m (132.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 40.8m (133.9ft),  Out-to-Out Width: 45.7m (149.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: M07779,  Location: 3.8 MI NORTH OF INT 8A (Lat: 40.405100,  Lng: -74.451214),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 91,953 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 112,200 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: IRELAND BROOK OVERPASS,  Facility Carried by Structure: NJ TPK NSO NSI RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 52.239,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M07781,  Location: 0.4mi. S. of CR 694 (Lat: 40.405381,  Lng: -74.450450),  Route carried "on" structure: Interstate 95,  Year Built: 1951,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 91,953 (year 2019),  Truck Traffic: 15%,  Average Future Daily Traffic: 112,200 (year 2039),  Design Load: HS 20,  Features Intersected: Ireland Brook,  Facility Carried by Structure: TPK NSI/SNI/SNO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 52.239,  Lanes on structure: 9,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 34 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: M07818,  Location: 4.2 MI NORTH OF INT 8A (Lat: 40.410692,  Lng: -74.449428),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 10.09m (33.10ft),  Average Daily Traffic: 14,723 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 18,114 (year 2041),  Design Load: HS 20,  Features Intersected: NJTPK NSO NSI SNO SNI,  Facility Carried by Structure: CHURCH LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.945,  Lanes on structure: 2,  Lanes under structure: 13,  Owner: State Toll Authority,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.7m (104.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M07846,  Location: 4.5 MI NORTH OF INT 8A (Lat: 40.414444,  Lng: -74.446694),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 7.96m (26.12ft),  Average Daily Traffic: 8,046 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 9,817 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NJ TPK SNO ROADWAY,  Facility Carried by Structure: NJ TPK SISA RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 52.883,  Lanes on structure: 1,  Lanes under structure: 4,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M07904,  Location: 5 MI NORTH OF INT 8A (Lat: 40.421711,  Lng: -74.441867),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 10.27m (33.69ft),  Average Daily Traffic: 8,000 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 9,761 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NJ TPK SNO ROADWAY,  Facility Carried by Structure: NJ TPK SANI RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.525,  Lanes on structure: 1,  Lanes under structure: 3,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 28.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M07915,  Location: 3.55 M South of Rt.18 (Lat: 40.423419,  Lng: -74.441583),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 91,952 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 112,199 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SO BRANCH BEAVERDAM *,  Facility Carried by Structure: NJ TPK NSO & NSI*
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.396,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 34.7m (113.8ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 36.4m (119.4ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M0793,  Location: 4 MI SOUTH OF INT 9 (Lat: 40.425333,  Lng: -74.440644),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 10.36m (33.99ft),  Average Daily Traffic: 3,865 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,716 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NJ TPK NSO NSI SNI SNO *,  Facility Carried by Structure: HARDENBURG LANE *
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.966,  Lanes on structure: 2,  Lanes under structure: 13,  Owner: State Toll Authority,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M07946I,  Location: 3.8 MI SOUTH OF INT 9 (Lat: 40.426089,  Lng: -74.439389),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 31.94m (104.79ft),  Average Daily Traffic: 46,836 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 57,149 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: NO BR BEAVERDAM BROOK,  Facility Carried by Structure: NSI ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.814,  Lanes on structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 18.1m (59.4ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Excellent,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M07946S,  Location: 3.8 MI SOUTH OF INT 9 (Lat: 40.426589,  Lng: -74.439258),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 26.70m (87.60ft),  Average Daily Traffic: 45,116 (year 2021),  Truck Traffic: 21%,  Average Future Daily Traffic: 55,050 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NO BRANCH BEAVERDAM *,  Facility Carried by Structure: NJ TPK NSO ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.814,  Lanes on structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 17.7m (58.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 18.1m (59.4ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Excellent,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M07980R,  Location: 3.5 MI SOUTH OF INT 9 (Lat: 40.431597,  Lng: -74.435597),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 9.05m (29.69ft),  Average Daily Traffic: 2,348 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,865 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NJ TPK NSO-NSI-SNI-SNO,  Facility Carried by Structure: DUTCH ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Toll Authority,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M08158,  Location: 1.5 MI S INT. 9 (Lat: 40.454667,  Lng: -74.420389),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 112,405 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 137,155 (year 2041),  Design Load: HS 20,  Features Intersected: TICES LANE,  Facility Carried by Structure: NSI & SNI RDWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.323,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 35.4m (116.1ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 35.4m (116.1ft),  Out-to-Out Width: 39.0m (128.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 50.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.10m (20.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $250,000,  Roadway Improvement Cost: $90,000,  Total Project Cost: $450,000 ( Estimate for 2015),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: M08158N,  Location: 1.5 MI SOUTH OF INT 9 (Lat: 40.454528,  Lng: -74.419944),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 45,116 (year 2021),  Truck Traffic: 20%,  Average Future Daily Traffic: 55,050 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: TICES LANE,  Facility Carried by Structure: NJ TPK SNO ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.323,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.14m (10.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $250,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $450,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M08158S,  Location: 1.5 MI SOUTH OF INT 9 (Lat: 40.454722,  Lng: -74.420583),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 45,116 (year 2021),  Truck Traffic: 21%,  Average Future Daily Traffic: 55,050 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: TICES LANE,  Facility Carried by Structure: NJ TPK NSO ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.323,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M08166,  Location: 1.4 MI S INTERCHANGE 9 (Lat: 40.455625,  Lng: -74.419306),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 65,334 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 65,334 (year 2041),  Features Intersected: SAW MILL BROOK,  Facility Carried by Structure: NJTP SNI-NSI RWYS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.451,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 37.2m (122.0ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 37.2m (122.0ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: M08166N,  Location: 1.4 MI SOUTH OF INT 9 (Lat: 40.455486,  Lng: -74.419294),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 45,116 (year 2021),  Truck Traffic: 31%,  Average Future Daily Traffic: 55,050 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SAWMILL BROOK,  Facility Carried by Structure: NJ TPK SNO ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.451,  Lanes on structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 17.9m (58.7ft),  Out-to-Out Width: 18.8m (61.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Excellent,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 61.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M08166S,  Location: 1.4 MI SOUTH OF INT 9 (Lat: 40.455794,  Lng: -74.419803),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 15.15m (49.70ft),  Average Daily Traffic: 41,156 (year 2021),  Truck Traffic: 31%,  Average Future Daily Traffic: 55,050 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: SAWMILL BROOK,  Facility Carried by Structure: NJ TPK NSO ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.451,  Lanes on structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.5m (60.7ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Excellent,  Operating Rating: 78.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 60.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M08215R,  Location: 1.2 MI SOUTH OF INT 9 (Lat: 40.462581,  Lng: -74.415950),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 8.20m (26.90ft),  Average Daily Traffic: 6,216 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,584 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NJ TPK,  Facility Carried by Structure: SULLIVAN WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.901,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 92.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 71.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M08295,  Location: 0.3 MI S OF INT. 9 (Lat: 40.473244,  Lng: -74.409536),  Route carried "on" structure: State highway 18,  Year Built: 1974,  Status: Open,  Structure Length: 20.76m (68.11ft),  Average Daily Traffic: 107,810 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 131,549 (year 2041),  Design Load: HS 20,  Features Intersected: NJTPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 63.698,  Lanes on structure: 6,  Lanes under structure: 15,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 34 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 40.8m (133.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 29.0m (95.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 20.76m (68.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $16,507,000,  Roadway Improvement Cost: $1,651,000,  Total Project Cost: $18,157,000 ( Estimate for 2015),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: M08325,  Location: .05 MI SOUTH OF INT 9 (Lat: 40.476097,  Lng: -74.405839),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1974,  Status: Open,  Structure Length: 5.39m (17.68ft),  Average Daily Traffic: 4,616 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,634 (year 2041),  Design Load: HS 20,  Features Intersected: NJ TPK(I-95) SNO ROADWAY,  Facility Carried by Structure: NJTPK INT9 RMP SIT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.994,  Lanes on structure: 1,  Lanes under structure: 3,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.9m (121.1ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 54.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: M0833,  Location: AT INTERCHANGE 9 (Lat: 40.477350,  Lng: -74.406378),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 3,820 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 4,661 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: NJ TPK NSO RWY,  Facility Carried by Structure: NJ TPK TSI RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.075,  Lanes on structure: 1,  Lanes under structure: 3,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 6 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: M08336,  Location: .05 MI NORTH OF INT 9 (Lat: 40.477261,  Lng: -74.404567),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1973,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 17,172 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 20,954 (year 2041),  Design Load: HS 20,  Features Intersected: NJTPK (I-95) SNO ROADWAY,  Facility Carried by Structure: NJTPK INT 9 RP TNI
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.171,  Lanes on structure: 1,  Lanes under structure: 3,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 8.6m (28.2ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.9m (98.1ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: M08342,  Location: .1 MI NORTH OF INT 9 (Lat: 40.478344,  Lng: -74.405786),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1973,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 16.46m (54.00ft),  Average Daily Traffic: 38,848 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 47,402 (year 2041),  Design Load: HS 20,  Features Intersected: NJ TPK NSO NSI SNI SNO*,  Facility Carried by Structure: NJ TPK ST-TN RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.268,  Lanes on structure: 3,  Lanes under structure: 14,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 29 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 35.7m (117.1ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 22.2m (72.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.33m (17.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $171,000,  Roadway Improvement Cost: $36,000,  Total Project Cost: $285,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other