Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Huntersville, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 104Number of bridges
  • 883ft / 269mTotal length
  • 2,016,219Total average daily traffic
  • 287,825Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Huntersville
  • No street view available for this location

New bridges in Huntersville, NC - historical statistics
  • New bridges - historical statistics
  • 51950-1959
  • 31960-1969
  • 191970-1979
  • 61980-1989
  • 171990-1999
  • 202000-2009
  • 342010-2019
Reconstructed bridges in Huntersville, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 21980-1989
  • 01990-1999
  • 42000-2009
Average Bridge Daily Traffic in Huntersville, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Very good
  • 52.4%Good
  • 28.6%Satisfactory
  • 2.4%Fair
  • 2.4%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 50.0%Very good
  • 33.3%Good
  • 11.9%Satisfactory
  • 2.4%Fair
  • 2.4%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.9%Very good
  • 54.8%Good
  • 23.8%Satisfactory
  • 9.5%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 5.1%Very good
  • 71.8%Good
  • 17.9%Satisfactory
  • 2.6%Fair
  • 2.6%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 43.5%Good
  • 43.5%Satisfactory
  • 13.0%Fair
Find on map >>   Show street view

Structure Number: 250008,  Location: 0.4 MI. S. JCT. SR1394 (Lat: 35.414039,  Lng: -80.752169),  Route carried "on" structure: State highway 1449,  Year Built: 2000,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 11,000 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 22,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CLARKE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 250029,  Location: 0.3 MI. W. JCT. SR1602 (Lat: 35.441950,  Lng: -80.752042),  Route carried "on" structure: State highway 73,  Year Built: 1969,  Status: Open,  Structure Length: 5.51m (18.08ft),  Average Daily Traffic: 15,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 31,000 (year 2040),  Design Load: HS 15,  Features Intersected: ROCKY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 73),  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 33001,  Location: 1.5 MI. E. JCT. NC62 (Lat: 36.446522,  Lng: -79.253297),  Route carried "on" structure: State highway 1597,  Year Built: 2005,  Status: Open,  Structure Length: 10.82m (35.50ft),  Average Daily Traffic: 130 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 260 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COUNTRY LINE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 74.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090041,  Location: 0.6 MI. E. JCT. SR1386 (Lat: 35.451122,  Lng: -81.010083),  Route carried "on" structure: State highway 73,  Year Built: 1968,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 9,200 (year 2013),  Truck Traffic: 12%,  Average Future Daily Traffic: 18,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: FORNEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 22.5m (73.8ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 109023,  Location: 0.9 MI. S. JCT. SR1203 (Lat: 35.491969,  Lng: -81.306194),  Route carried "on" structure: State highway 1202,  Year Built: 1976,  Status: Open,  Structure Length: 4.14m (13.58ft),  Average Daily Traffic: 1,300 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,600 (year 2025),  Design Load: HS 15,  Features Intersected: HOWARDS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 47.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1090234,  Location: 0.7 MI. N. JCT. NC16 (Lat: 35.447375,  Lng: -81.010892),  Route carried "on" structure: State highway 1386,  Year Built: 1996,  Status: Open,  Structure Length: 1.21m (3.97ft),  Average Daily Traffic: 890 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,780 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: FORNEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1090282,  Location: 0.07 MI. E. JCT. SR1941 (Lat: 35.417669,  Lng: -80.998572),  Route carried "on" structure: State highway 1397,  Year Built: 2005,  Status: Open,  Structure Length: 7.49m (24.57ft),  Average Daily Traffic: 1,700 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC16
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090285,  Location: 1 MI. S. JCT. NC73 (Lat: 35.435442,  Lng: -81.005656),  Route carried "on" structure: State highway 16,  Year Built: 2005,  Status: Open,  Structure Length: 6.73m (22.08ft),  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 26,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NEW NC 16
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090304,  Location: .15 MI. S. JCT. SR1529 (Lat: 35.496542,  Lng: -81.187786),  Route carried "on" structure: State highway 1530,  Year Built: 2006,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 90 (year 2006),  Average Future Daily Traffic: 180 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: Lick Run Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1090307,  Location: 0.35 MI. W. JCT. SR1395 (Lat: 35.439878,  Lng: -80.968397),  Route carried "on" structure: State highway 1872,  Year Built: 2010,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 2,500 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CATAWBA RIVER TRIB. 6
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 1190095,  Location: 0.6 MI. S. JCT. NC73 (Lat: 35.442156,  Lng: -80.801744),  Route carried "on" structure: State highway 2427,  Year Built: 1994,  Status: Open,  Structure Length: 2.34m (7.68ft),  Average Daily Traffic: 3,700 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: RAMAH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190096,  Location: 1.1 MI. E. JCT. SR2425 (Lat: 35.424208,  Lng: -80.765236),  Route carried "on" structure: State highway 2426,  Year Built: 1951,  Year Reconstructed: 1982,  Status: Posted for load,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 4,500 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,000 (year 2040),  Features Intersected: RAMAH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.9m (35.8ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.0m (19.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190097,  Location: 0.6 MI. N. JCT. SR2426 (Lat: 35.430081,  Lng: -80.780317),  Route carried "on" structure: State highway 2425,  Year Built: 1959,  Status: Posted for load,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 70 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 140 (year 2040),  Features Intersected: RAMAH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Very good,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 28.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 1190098,  Location: 0.5 MI. S. JCT. SR2426 (Lat: 35.420208,  Lng: -80.797964),  Route carried "on" structure: State highway 2442,  Year Built: 1974,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 5,400 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: N. PRONG CLARK'S CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 11901,  Location: 0.9 MI. N. JCT. SR2074 (Lat: 35.365128,  Lng: -80.886139),  Route carried "on" structure: State highway 2120,  Year Built: 2012,  Status: Open,  Structure Length: 1.76m (5.77ft),  Average Daily Traffic: 3,200 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 6,400 (year 2040),  Design Load: HL 93,  Features Intersected: GAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.7m (54.8ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190101,  Location: 0.15 MI. N. JCT. I277 (Lat: 35.236750,  Lng: -80.838444),  Route carried "on" structure: US 29,  Year Built: 1994,  Status: Open,  Structure Length: 4.14m (13.58ft),  Average Daily Traffic: 20,000 (year 2012),  Truck Traffic: 12%,  Average Future Daily Traffic: 40,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SEABOARD COASTLINE RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 29),  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.8m (61.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 23.1m (75.8ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190102,  Location: 0.7 MI. N. JCT. SR2004 (Lat: 35.365658,  Lng: -80.874478),  Route carried "on" structure: State highway 2119,  Year Built: 1997,  Status: Open,  Structure Length: 1.21m (3.97ft),  Average Daily Traffic: 2,900 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: GAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 87.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 1190109,  Location: 0.2 MI. S. JCT. SR2136 (Lat: 35.401181,  Lng: -80.869672),  Route carried "on" structure: State highway 2138,  Year Built: 1955,  Year Reconstructed: 1986,  Status: Posted for load,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 11,000 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 22,000 (year 2040),  Features Intersected: TORRENCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 46.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190112,  Location: 0.75 MI. E. JCT. SR2131 (Lat: 35.407014,  Lng: -80.890858),  Route carried "on" structure: State highway 2136,  Year Built: 1965,  Status: Open,  Structure Length: 4.17m (13.68ft),  Average Daily Traffic: 12,000 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 24,000 (year 2040),  Design Load: H 15,  Features Intersected: MCDOWELL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190128,  Location: 0.4 MI. W. JCT. SR1226 (Lat: 35.401722,  Lng: -80.917653),  Route carried "on" structure: State highway 2131,  Year Built: 2013,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 3,700 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,400 (year 2040),  Design Load: HL 93,  Features Intersected: BRANCH MCDOWELL CRK.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190129,  Location: 0.1 MI. N. JCT. SR2130 (Lat: 35.389564,  Lng: -80.920947),  Route carried "on" structure: State highway 2128,  Year Built: 1974,  Status: Open,  Structure Length: 3.65m (11.98ft),  Average Daily Traffic: 11,000 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 22,000 (year 2040),  Design Load: HS 15,  Features Intersected: MCDOWELL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190131,  Location: 0.5 MI. W. JCT. SR2126 (Lat: 35.380669,  Lng: -80.940133),  Route carried "on" structure: State highway 2074,  Year Built: 2003,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 1,800 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MCDOWELL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190173,  Location: 0.10 MI. E. JCT. SR3300 (Lat: 35.219472,  Lng: -80.825036),  Route carried "on" structure: State highway 27,  Year Built: 1996,  Status: Open,  Structure Length: 9.47m (31.07ft),  Average Daily Traffic: 13,375 (year 2016),  Truck Traffic: 12%,  Average Future Daily Traffic: 26,750 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US74
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 27),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 38.7m (127.0ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 65.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190176,  Location: 0.52 MI. N. JCT. SR2695 (Lat: 35.398322,  Lng: -80.851250),  Route carried "on" structure: US 21,  Year Built: 1955,  Status: Open,  Structure Length: 4.84m (15.88ft),  Average Daily Traffic: 14,000 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 28,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR2004
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.0m (55.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190185,  Location: 0.2 MI. W. JCT. SR2602 (Lat: 35.426772,  Lng: -80.814389),  Route carried "on" structure: State highway 2439,  Year Built: 1985,  Status: Open,  Structure Length: 1.18m (3.87ft),  Average Daily Traffic: 7,900 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 15,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORTH PRONG CLARKE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 119035,  Location: 0.12 MI. W. JCT. US21 (Lat: 35.368275,  Lng: -80.842597),  Route carried "on" structure: State highway 2116,  Year Built: 2008,  Status: Open,  Structure Length: 22.06m (72.38ft),  Average Daily Traffic: 12,000 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 24,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I77 & RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 14,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 64.3m (211.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 65.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190351,  Location: 0.35 MI. N. JCT. SR2116 (Lat: 35.373522,  Lng: -80.845431),  Route carried "on" structure: Interstate 77,  Year Built: 2019,  Status: Open,  Structure Length: 3.74m (12.27ft),  Average Daily Traffic: 50,000 (year 2018),  Truck Traffic: 16%,  Average Future Daily Traffic: 100,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLONIALPIPELINE(DIRT)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.086,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 77),  Owner: State Highway Agency,  Approaching Roadway Width: 42.3m (138.8ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 42.2m (138.5ft),  Out-to-Out Width: 43.4m (142.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 87.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190352,  Location: 0.35 MI. N. JCT. SR2116 (Lat: 35.373175,  Lng: -80.845703),  Route carried "on" structure: Interstate 77,  Year Built: 2005,  Status: Open,  Structure Length: 3.74m (12.27ft),  Average Daily Traffic: 50,000 (year 2018),  Truck Traffic: 16%,  Average Future Daily Traffic: 100,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLONIAL PIPE LINE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.096,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 77),  Owner: State Highway Agency,  Approaching Roadway Width: 33.2m (108.9ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 38.5m (126.3ft),  Out-to-Out Width: 39.5m (129.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190353,  Location: 0.25 MI. W. JCT. US21 (Lat: 35.376242,  Lng: -80.847058),  Route carried "on" structure: State highway 2117,  Year Built: 2019,  Status: Open,  Structure Length: 10.75m (35.27ft),  Average Daily Traffic: 6,600 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 13,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-77
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.126,  Lanes on structure: 5,  Lanes under structure: 13,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 37.4m (122.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 20.4m (66.9ft),  Out-to-Out Width: 26.0m (85.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190355,  Location: 0.36 MI. W. JCT. US21 (Lat: 35.393850,  Lng: -80.852883),  Route carried "on" structure: State highway 2004,  Year Built: 1975,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 10.85m (35.60ft),  Average Daily Traffic: 9,700 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 19,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I77
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 40.8m (133.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 1190356,  Location: 0.17 MI.W.JCT.US21 (Lat: 35.409147,  Lng: -80.857403),  Route carried "on" structure: State highway 2136,  Year Built: 1975,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 10.69m (35.07ft),  Average Daily Traffic: 32,500 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 65,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I77
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 31.3m (102.7ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1190357,  Location: 0.5 MI. W. JCT. US21 (Lat: 35.421883,  Lng: -80.862089),  Route carried "on" structure: State highway 2140,  Year Built: 1975,  Status: Posted for load,  Structure Length: 10.30m (33.79ft),  Average Daily Traffic: 12,000 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 24,000 (year 2040),  Design Load: HS 15,  Features Intersected: I77
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 30.7m (100.7ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190358,  Location: 0.16 MI. W. JCT. US21 (Lat: 35.442372,  Lng: -80.868422),  Route carried "on" structure: State highway 73,  Year Built: 1992,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 4.84m (15.88ft),  Average Daily Traffic: 43,000 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 96,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I77 NBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 73),  Owner: State Highway Agency,  Approaching Roadway Width: 26.5m (86.9ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.0m (78.7ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 28.3m (92.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190359,  Location: 0.17 MI. W. JCT. US21 (Lat: 35.442436,  Lng: -80.869422),  Route carried "on" structure: State highway 73,  Year Built: 1992,  Status: Open,  Structure Length: 5.02m (16.47ft),  Average Daily Traffic: 43,000 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 96,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I77 SBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.559,  Lanes on structure: 5,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 73),  Owner: State Highway Agency,  Approaching Roadway Width: 25.9m (85.0ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 28.3m (92.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190453,  Location: 0.2 MI. N. JCT. SR2145 (Lat: 35.445617,  Lng: -80.868517),  Route carried "on" structure: Interstate 77,  Year Built: 1975,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 46,250 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 92,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CALDWELL STATION CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.620,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 77),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 11 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 119056,  Location: 0.6 MI.W.JCT.SR1142 (Lat: 35.144600,  Lng: -80.961647),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 100 (year 1991),  Average Future Daily Traffic: 200 (year 2040),  Features Intersected: STEELE CREEK TRIBUTARY,  Facility Carried by Structure: RED HICKORY LN.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.4m (17.7ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 59.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1190562,  Location: 0.2MI.S.JCT.GILEAD RD. (Lat: 35.403769,  Lng: -80.882947),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 100 (year 1991),  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TORRENCE CREEK,  Facility Carried by Structure: BRADFORD HILL LN.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.7m (22.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 73.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1190563,  Location: 0.03MI.S.JCT.GILEAD RD. (Lat: 35.404281,  Lng: -80.882550),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 100 (year 1991),  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UT TOTORRENCE CREEK,  Facility Carried by Structure: BRADFORD HILL LN.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1190565,  Location: 0.7 MI.N.JCT.GILEAD RD. (Lat: 35.411933,  Lng: -80.879617),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 100 (year 1991),  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UT TO TORRENCE CREEK,  Facility Carried by Structure: WINFIELD CRK.PKWY.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1190683,  Location: 0.2 MI. W. JCT. SR2316 (Lat: 35.443044,  Lng: -80.877678),  Route carried "on" structure: State highway 73,  Year Built: 1996,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 31,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 63,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MCDOWELL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 73),  Owner: State Highway Agency,  Approaching Roadway Width: 28.9m (94.8ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 79.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 1190684,  Location: 0.1 MI. W. JCT. SR2316 (Lat: 35.442897,  Lng: -80.876008),  Route carried "on" structure: State highway 73,  Year Built: 1996,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 42,000 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 84,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CALDWELL STATION CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 73),  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 79.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 1190973,  Location: 0.1 MI. E. JCT. I77 (Lat: 35.365656,  Lng: -80.838881),  Route carried "on" structure: Ramp Interstate 485,  Year Built: 2008,  Status: Open,  Structure Length: 11.15m (36.58ft),  Average Daily Traffic: 7,000 (year 2015),  Truck Traffic: 16%,  Average Future Daily Traffic: 14,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US21
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 60.0m (196.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190993,  Location: 0.2 MI. W. JCT. SR2138 (Lat: 35.405756,  Lng: -80.873217),  Route carried "on" structure: State highway 2136,  Year Built: 2004,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 18,000 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 36,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UT TO TORRENCE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 1191077,  Location: .4MI.E.JCT.BIRKDALE PKWY (Lat: 35.433633,  Lng: -80.885261),  Route carried "on" structure: City street ,  Year Built: 2009,  Status: Open,  Structure Length: 4.87m (15.98ft),  Average Daily Traffic: 150 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 300 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MCDOWELL CREEK,  Facility Carried by Structure: DEVONSHIRE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 49.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Huntersville, North Carolina (NC) on our hugely popular North Carolina forum.