Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Lincolnton, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 72Number of bridges
  • 833ft / 254mTotal length
  • 768,180Total average daily traffic
  • 82,583Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lincolnton
  • No street view available for this location

New bridges in Lincolnton, NC - historical statistics
  • New bridges - historical statistics
  • 61920-1929
  • 91950-1959
  • 91960-1969
  • 31970-1979
  • 51980-1989
  • 291990-1999
  • 72000-2009
  • 32010-2019
  • 12020-2022
Reconstructed bridges in Lincolnton, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 41950-1959
Average Bridge Daily Traffic in Lincolnton, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.2%Excellent
  • 6.5%Very good
  • 41.3%Good
  • 39.1%Satisfactory
  • 10.9%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 4.3%Excellent
  • 23.9%Very good
  • 37.0%Good
  • 19.6%Satisfactory
  • 10.9%Fair
  • 2.2%Poor
  • 2.2%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.2%Excellent
  • 15.2%Very good
  • 41.3%Good
  • 23.9%Satisfactory
  • 15.2%Fair
  • 2.2%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 5.4%Very good
  • 48.6%Good
  • 32.4%Satisfactory
  • 13.5%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 45.5%Good
  • 54.5%Satisfactory
Find on map >>   Show street view

Structure Number: 1090242,  Location: 0.2 MI. S. JCT. NC27 (Lat: 35.468200,  Lng: -81.255456),  Route carried "on" structure: State highway 1406,  Year Built: 2002,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 4,800 (year 2012),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SCL RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.5m (73.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 76.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090244,  Location: 0.8 MI. N. JCT. NC27 (Lat: 35.483458,  Lng: -81.257189),  Route carried "on" structure: State highway 1405,  Year Built: 1922,  Year Reconstructed: 1955,  Status: Posted for load,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 5,000 (year 2012),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,000 (year 2025),  Design Load: H 15,  Features Intersected: WALKER BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 47.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 109025,  Location: 0.3 MI.W.JCT.SR1002 (Lat: 35.538172,  Lng: -81.415186),  Route carried "on" structure: State highway 1113,  Year Built: 1950,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 950 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,900 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: INDIAN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 1090258,  Location: 0.01 MI. W. JCT. SR1442 (Lat: 35.499531,  Lng: -81.192536),  Route carried "on" structure: State highway 1335,  Year Built: 2004,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 840 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,680 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: LICK RUN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 87.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 1090264,  Location: 0.95 MI. N. JCT. SR1267 (Lat: 35.505156,  Lng: -81.223986),  Route carried "on" structure: State highway 1282,  Year Built: 1990,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 3,000 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 6,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US321
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090265,  Location: 1.0 MI. S. JCT. NC155 (Lat: 35.513856,  Lng: -81.223047),  Route carried "on" structure: State highway 1338,  Year Built: 1990,  Status: Open,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 940 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,880 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US321
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090266,  Location: 0.95 MI. S. JCT. SR1280 (Lat: 35.492281,  Lng: -81.230117),  Route carried "on" structure: State highway 1267,  Year Built: 1991,  Status: Open,  Structure Length: 6.15m (20.18ft),  Average Daily Traffic: 5,400 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US321
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090267,  Location: 0.2 MI. E. JCT. SR1279 (Lat: 35.528261,  Lng: -81.222769),  Route carried "on" structure: Business US 321,  Year Built: 1991,  Status: Open,  Structure Length: 5.45m (17.88ft),  Average Daily Traffic: 16,000 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US321
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.412,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 24.1m (79.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090268,  Location: 0.3 MI. E. JCT. SR1262 (Lat: 35.470022,  Lng: -81.222628),  Route carried "on" structure: State highway 1294,  Year Built: 1992,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 5,300 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US321
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 109027,  Location: 3.4 MI. S. JCT. SR1262 (Lat: 35.415694,  Lng: -81.211081),  Route carried "on" structure: Bypass US 321,  Year Built: 1992,  Status: Open,  Structure Length: 4.23m (13.88ft),  Average Daily Traffic: 17,250 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 34,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US321 BUS, NC155
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090271,  Location: 1.1 MI. S. JCT. NC27 (Lat: 35.462250,  Lng: -81.219664),  Route carried "on" structure: Bypass US 321,  Year Built: 1992,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 17,250 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 34,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1262
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.4m (76.8ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090272,  Location: 1.1 MI. S. JCT. NC27 (Lat: 35.462356,  Lng: -81.219947),  Route carried "on" structure: Business US 321,  Year Built: 1992,  Status: Open,  Structure Length: 5.66m (18.57ft),  Average Daily Traffic: 17,250 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 34,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1262
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.4m (76.8ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090274,  Location: 0.68 MI. N. JCT. NC155 (Lat: 35.537833,  Lng: -81.226606),  Route carried "on" structure: US 321,  Year Built: 1993,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 32,500 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 65,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LARKARD CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 22.8m (74.8ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 1090277,  Location: 0.1 MI. E. JCT. SR1419 (Lat: 35.478017,  Lng: -81.229503),  Route carried "on" structure: State highway 27,  Year Built: 1993,  Status: Open,  Structure Length: 7.83m (25.69ft),  Average Daily Traffic: 28,000 (year 2016),  Truck Traffic: 12%,  Average Future Daily Traffic: 56,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US321
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 27),  Owner: State Highway Agency,  Approaching Roadway Width: 23.1m (75.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 30.5m (100.1ft),  Out-to-Out Width: 31.3m (102.7ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1090278,  Location: 0.1MI.S.JCT.NC27 (Lat: 35.471481,  Lng: -81.251625),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 3.68m (12.07ft),  Average Daily Traffic: 1,200 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,400 (year 2040),  Features Intersected: CSX RAILROAD,  Facility Carried by Structure: S.CEDAR ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 109003,  Location: 0.07 MI. N. JCT. SR1250 (Lat: 35.453114,  Lng: -81.243994),  Route carried "under" structure: State highway 150,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 12,000 (year 2015),  Truck Traffic: 6%,  Features Intersected: US321 BUS
Minimum Vertical Clearance: 4.64m (15.22ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)

Find on map >>   Show street view

Structure Number: 1090264,  Location: 0.95 MI. N. JCT. SR1267 (Lat: 35.505156,  Lng: -81.223986),  Route carried "under" structure: US 321,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1282
Minimum Vertical Clearance: 5.10m (16.73ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090264,  Location: 0.95 MI. N. JCT. SR1267 (Lat: 35.505156,  Lng: -81.223986),  Route carried "under" structure: US 321,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1282
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090265,  Location: 1.0 MI. S. JCT. NC155 (Lat: 35.513856,  Lng: -81.223047),  Route carried "under" structure: US 321,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 14,000 (year 2013),  Truck Traffic: 12%,  Features Intersected: SR1338
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090265,  Location: 1.0 MI. S. JCT. NC155 (Lat: 35.513856,  Lng: -81.223047),  Route carried "under" structure: US 321,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1338
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090266,  Location: 0.95 MI. S. JCT. SR1280 (Lat: 35.492281,  Lng: -81.230117),  Route carried "under" structure: US 321,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1267
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090266,  Location: 0.95 MI. S. JCT. SR1280 (Lat: 35.492281,  Lng: -81.230117),  Route carried "under" structure: US 321,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1267
Minimum Vertical Clearance: 6.01m (19.72ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090267,  Location: 0.2 MI. E. JCT. SR1279 (Lat: 35.528261,  Lng: -81.222769),  Route carried "under" structure: US 321,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: US321 BUS
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 8.534,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090267,  Location: 0.2 MI. E. JCT. SR1279 (Lat: 35.528261,  Lng: -81.222769),  Route carried "under" structure: US 321,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 182,500 (year 2013),  Truck Traffic: 12%,  Features Intersected: US321 BUS
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 8.534,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1090268,  Location: 0.3 MI. E. JCT. SR1262 (Lat: 35.470022,  Lng: -81.222628),  Route carried "under" structure: US 321,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1294
Minimum Vertical Clearance: 5.91m (19.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>   Show street view

Structure Number: 1090268,  Location: 0.3 MI. E. JCT. SR1262 (Lat: 35.470022,  Lng: -81.222628),  Route carried "under" structure: US 321,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1294
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>   Show street view

Structure Number: 1090271,  Location: 1.1 MI. S. JCT. NC27 (Lat: 35.462250,  Lng: -81.219664),  Route carried "under" structure: State highway 1262,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 4,200 (year 2016),  Truck Traffic: 7%,  Features Intersected: US321 NBL
Minimum Vertical Clearance: 4.71m (15.45ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.4m (76.8ft)

Find on map >>   Show street view

Structure Number: 1090272,  Location: 1.1 MI. S. JCT. NC27 (Lat: 35.462356,  Lng: -81.219947),  Route carried "under" structure: State highway 1262,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 8,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: US321 SBL
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.4m (76.8ft)

Find on map >>   Show street view

Structure Number: 1090277,  Location: 0.1 MI. E. JCT. SR1419 (Lat: 35.478017,  Lng: -81.229503),  Route carried "under" structure: US 321,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: NC27 & NC150
Minimum Vertical Clearance: 8.40m (27.56ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 1090277,  Location: 0.1 MI. E. JCT. SR1419 (Lat: 35.478017,  Lng: -81.229503),  Route carried "under" structure: US 321,  Year Built: 1993,  Structure Length: 0. m,  Average Daily Traffic: 18,250 (year 2018),  Truck Traffic: 12%,  Features Intersected: NC27 & NC150
Minimum Vertical Clearance: 7.64m (25.07ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Discuss Lincolnton, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.