Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Mansfield, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 69Number of bridges
  • 587ft / 179mTotal length
  • $7,011,000Total costs
  • 186,112Total average daily traffic
  • 34,779Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Mansfield
  • No street view available for this location

New bridges in Mansfield, PA - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 41930-1939
  • 31940-1949
  • 91950-1959
  • 21960-1969
  • 121970-1979
  • 151980-1989
  • 21990-1999
  • 172000-2009
  • 42010-2019
Reconstructed bridges in Mansfield, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 51980-1989
  • 61990-1999
  • 12000-2009
  • 12010-2019
Average Bridge Daily Traffic in Mansfield, PA
Average Bridge Truck Traffic in Mansfield, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.1%Excellent
  • 14.9%Very good
  • 51.1%Good
  • 19.1%Satisfactory
  • 10.6%Fair
  • 2.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 19.1%Very good
  • 34.0%Good
  • 21.3%Satisfactory
  • 23.4%Fair
  • 2.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 6.4%Very good
  • 40.4%Good
  • 25.5%Satisfactory
  • 25.5%Fair
  • 2.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 8.5%Very good
  • 29.8%Good
  • 19.1%Satisfactory
  • 29.8%Fair
  • 12.8%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 22.2%Very good
  • 44.4%Good
  • 33.3%Satisfactory
Find on map >>   Show street view

Structure Number: 41459,  Location: 1 MI S. OF MANSFIELD (Lat: 41.780986,  Lng: -77.077894),  Route carried "on" structure: US 15,  Year Built: 2001,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 4,202 (year 2020),  Truck Traffic: 29%,  Average Future Daily Traffic: 9,391 (year 2032),  Design Load: HL 93,  Features Intersected: TWP ROAD 493
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.377,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 71.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.10m (13.45ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4146,  Location: 0.5 M NW OF MANSFIELD (Lat: 41.818883,  Lng: -77.089969),  Route carried "on" structure: Bypass US 15,  Year Built: 2001,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 5,377 (year 2022),  Truck Traffic: 23%,  Average Future Daily Traffic: 4,616 (year 2032),  Design Load: HL 93,  Features Intersected: OVER SR 1001
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.857,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 96.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.50m (18.04ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41461,  Location: 0.5 MI N OF MANSFIELD (Lat: 41.823792,  Lng: -77.088186),  Route carried "on" structure: Bypass US 15,  Year Built: 2001,  Status: Open,  Structure Length: 16.46m (54.00ft),  Average Daily Traffic: 5,377 (year 2022),  Truck Traffic: 23%,  Average Future Daily Traffic: 4,616 (year 2032),  Design Load: HL 93,  Features Intersected: TIOGA RIVER & SR 8003
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.318,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 40.8m (133.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 16.50m (54.13ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42126,  Location: 0.4 MI W OF CANOE CAMP (Lat: 41.785914,  Lng: -77.075578),  Route carried "on" structure: City street ,  Year Built: 2003,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 77 (year 2043),  Features Intersected: SLATE CREEK,  Facility Carried by Structure: T-754 RICHMOND TWP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 69.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.60m (1.97ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 42227,  Location: BORO. OF MANSFIELD (Lat: 41.774678,  Lng: -77.072031),  Route carried "on" structure: US 15,  Year Built: 2003,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 4,202 (year 2020),  Truck Traffic: 29%,  Average Future Daily Traffic: 9,391 (year 2032),  Design Load: HL 93,  Features Intersected: NB OVER SR 2005
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.521,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.7m (113.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.40m (14.44ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42228,  Location: BORO OF MANSFIELD (Lat: 41.774511,  Lng: -77.072144),  Route carried "on" structure: US 15,  Year Built: 2003,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 4,148 (year 2020),  Truck Traffic: 27%,  Average Future Daily Traffic: 7,130 (year 2032),  Design Load: HL 93,  Features Intersected: SB OVER SR 2005
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.497,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.7m (113.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 84.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.50m (14.76ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42239,  Location: BORO OF MANSFIELD (Lat: 41.803842,  Lng: -77.091514),  Route carried "on" structure: Bypass US 15,  Year Built: 2003,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 4,202 (year 2020),  Truck Traffic: 29%,  Average Future Daily Traffic: 9,391 (year 2032),  Design Load: HL 93,  Features Intersected: ROUTE 6
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.161,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.5m (136.2ft),  Curb-To-Curb Width: 15.7m (51.5ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.20m (17.06ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42277,  Location: 1.5 MILE S. MANSFIELD (Lat: 41.777050,  Lng: -77.074236),  Route carried "on" structure: Bypass US 15,  Year Built: 2003,  Status: Open,  Structure Length: 14.39m (47.21ft),  Average Daily Traffic: 4,202 (year 2020),  Truck Traffic: 29%,  Average Future Daily Traffic: 9,391 (year 2032),  Design Load: HL 93,  Features Intersected: TIOGA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.521,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 36.9m (121.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 87.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 15.20m (49.87ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 46057,  Location: 1.25 MI NE OF MANSFIELD (Lat: 41.816853,  Lng: -77.056350),  Route carried "on" structure: State highway ,  Year Built: 2010,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 409 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 627 (year 2032),  Design Load: HL 93,  Features Intersected: TRIB COREY CREEK,  Facility Carried by Structure: SR 1002
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.163,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 4.6m (15.1ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Channel: Poor,  Culverts: Very good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019
Find on map >>   Show street view

Structure Number: 46692,  Location: VILLAGE OF PENNS CREEK (Lat: 41.856944,  Lng: -77.056111),  Route carried "on" structure: State highway ,  Year Built: 2011,  Status: Open,  Structure Length: 2.10m (6.89ft),  Average Daily Traffic: 532 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 723 (year 2032),  Design Load: HL 93,  Features Intersected: DRY RUN,  Facility Carried by Structure: SR 1001
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.854,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 47318,  Location: 0.4 MI WEST OF COVINGTON (Lat: 41.746283,  Lng: -77.083753),  Route carried "on" structure: City street ,  Year Built: 2012,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 120 (year 2021),  Average Future Daily Traffic: 186 (year 2043),  Design Load: HL 93,  Features Intersected: TRIB TO TIOGA RIVER,  Facility Carried by Structure: T-750 KENDRICK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 56871,  Location: 2.8M E OF WHITNEYVILLE (Lat: 41.775100,  Lng: -77.146428),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 61 (year 2043),  Design Load: HS 20,  Features Intersected: NORTH ELK RUN,  Facility Carried by Structure: T-678 (S. BULLOCK)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: CEPNABPA-000001,  Location: INDIAN ROCK DAM, PA (Lat: 39.922394,  Lng: -76.753183),  Route carried "on" structure: ServiceFederal lands road ,  Year Built: 1949,  Year Reconstructed: 1989,  Status: Posted for load,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 400 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 500 (year 2037),  Design Load: H 15,  Features Intersected: INDIAN ROCK DAM,  Facility Carried by Structure: ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Truss - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.7m (87.6ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 5.4m (17.7ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 34.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 5.29m (17.36ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Bridge Improvement Cost: $454,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $455,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: CEPNABPA-000004,  Location: TIOGA-HAMMOND LAKES (Lat: 41.877950,  Lng: -77.188569),  Route carried "on" structure: ServiceFederal lands road ,  Year Built: 1979,  Status: Posted for load,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 200 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2042),  Design Load: HS 15,  Features Intersected: STEPHENHOUSE RUN,  Facility Carried by Structure: ADMIN ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.4m (40.7ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 5.4m (17.7ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.13m (0.43ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $27,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $28,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: CEPNABPA-000005,  Location: TIOGA-HAMMOND LAKES (Lat: 41.887325,  Lng: -77.178367),  Route carried "on" structure: ServiceFederal lands road ,  Year Built: 1979,  Status: Posted for load,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 200 (year 2011),  Truck Traffic: 20%,  Average Future Daily Traffic: 200 (year 2037),  Design Load: HS 15,  Features Intersected: IVES RUN,  Facility Carried by Structure: CAMP ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.4m (40.7ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 30.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.46m (8.07ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $112,000,  Roadway Improvement Cost: $11,000,  Total Project Cost: $168,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: CEPNABPA-000006,  Location: TIOGA-HAMMOND LAKES (Lat: 41.888592,  Lng: -77.181178),  Route carried "on" structure: ServiceFederal lands road ,  Year Built: 1979,  Status: Posted for load,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 700 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 700 (year 2039),  Design Load: HS 15,  Features Intersected: IVES RUN,  Facility Carried by Structure: DAY USE ACCESS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.4m (40.7ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 31.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.46m (8.07ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $33,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $34,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: CEPNABPA-000007,  Location: TIOGA-HAMMOND LAKES (Lat: 41.841547,  Lng: -77.103217),  Route carried "on" structure: Federal lands road ,  Year Built: 1936,  Year Reconstructed: 1988,  Status: Closed,  Structure Length: 5.15m (16.90ft),  Average Future Daily Traffic: 1 (year 2041),  Features Intersected: LAMBS CREEK,  Facility Carried by Structure: LAMBS CR ACCESS RD
Minimum Vertical Clearance: 4.03m (13.22ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 51.5m (169.0ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Length Of Structure Improvement: 9.63m (31.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $33,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $50,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 33228,  Location: BORO OF MANSFIELD (Lat: 41.803839,  Lng: -77.091750),  Route carried "under" structure: US 6,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 3,612 (year 2020),  Truck Traffic: 8%,  Features Intersected: SR 0006,  Facility Carried by Structure: SR 15
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 52.125,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>   Show street view

Structure Number: 33228,  Location: BORO OF MANSFIELD (Lat: 41.803839,  Lng: -77.091750),  Route carried "under" structure: US 6,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 3,612 (year 2020),  Truck Traffic: 8%,  Features Intersected: SR 0006,  Facility Carried by Structure: SR 15
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 52.125,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>   Show street view

Structure Number: 33229,  Location: 0.5 MI. NW OF MANSFIELD (Lat: 41.818706,  Lng: -77.089794),  Route carried "under" structure: State highway ,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 466 (year 2022),  Truck Traffic: 8%,  Features Intersected: SR 1001,  Facility Carried by Structure: SR 0015
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 6.822,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.7m (140.1ft)

Find on map >>   Show street view

Structure Number: 3323,  Location: 0.5 MI. N. OF MANSFIELD (Lat: 41.823586,  Lng: -77.087964),  Route carried "under" structure: Ramp State highway ,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 795 (year 2022),  Truck Traffic: 8%,  Features Intersected: TIOGA RIVER & SR 8003,  Facility Carried by Structure: SR 15
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 3323,  Location: 0.5 MI. N. OF MANSFIELD (Lat: 41.823586,  Lng: -77.087964),  Route carried "under" structure: Ramp State highway ,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 832 (year 2022),  Truck Traffic: 8%,  Features Intersected: TIOGA RIVER & SR 8003,  Facility Carried by Structure: SR 15
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 41459,  Location: 1 MI S. OF MANSFIELD (Lat: 41.780986,  Lng: -77.077894),  Route carried "under" structure: City street ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 310 (year 2009),  Truck Traffic: 3%,  Features Intersected: TWP ROAD 493,  Facility Carried by Structure: SR 15 FUTURE NB
Minimum Vertical Clearance: 6.50m (21.33ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 4146,  Location: 0.5 M NW OF MANSFIELD (Lat: 41.818883,  Lng: -77.089969),  Route carried "under" structure: State highway ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 466 (year 2022),  Truck Traffic: 8%,  Features Intersected: OVER SR 1001,  Facility Carried by Structure: FUTURE SR15 NB
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 6.822,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.7m (140.1ft)

Find on map >>   Show street view

Structure Number: 41461,  Location: 0.5 MI N OF MANSFIELD (Lat: 41.823792,  Lng: -77.088186),  Route carried "under" structure: Ramp State highway ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 832 (year 2022),  Truck Traffic: 8%,  Features Intersected: TIOGA RIVER & SR 8003,  Facility Carried by Structure: RAMP 15 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 41461,  Location: 0.5 MI N OF MANSFIELD (Lat: 41.823792,  Lng: -77.088186),  Route carried "under" structure: Ramp State highway ,  Year Built: 2001,  Structure Length: 0. m,  Average Daily Traffic: 795 (year 2022),  Truck Traffic: 8%,  Features Intersected: TIOGA RIVER & SR 8003,  Facility Carried by Structure: RAMP 15 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.8m (133.9ft)

Find on map >>   Show street view

Structure Number: 42227,  Location: BORO. OF MANSFIELD (Lat: 41.774678,  Lng: -77.072031),  Route carried "under" structure: Ramp US 15B,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 8,573 (year 2019),  Truck Traffic: 6%,  Features Intersected: NB OVER SR 2005,  Facility Carried by Structure: SR 15
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 26.017,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 42228,  Location: BORO OF MANSFIELD (Lat: 41.774511,  Lng: -77.072144),  Route carried "under" structure: Ramp State highway 660,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 6,157 (year 2022),  Truck Traffic: 7%,  Features Intersected: SB OVER SR 2005,  Facility Carried by Structure: SR15 SOUTHBOUND
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 27.792,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 42239,  Location: BORO OF MANSFIELD (Lat: 41.803842,  Lng: -77.091514),  Route carried "under" structure: US 6,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 3,612 (year 2020),  Truck Traffic: 8%,  Features Intersected: ROUTE 6,  Facility Carried by Structure: SR 15 SOUTHBOUND
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 52.125,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.5m (136.2ft)

Find on map >>   Show street view

Structure Number: 42239,  Location: BORO OF MANSFIELD (Lat: 41.803842,  Lng: -77.091514),  Route carried "under" structure: US 6,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 3,612 (year 2020),  Truck Traffic: 8%,  Features Intersected: ROUTE 6,  Facility Carried by Structure: SR 15 SOUTHBOUND
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 52.125,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 41.5m (136.2ft)

Discuss Mansfield, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.