  • National Bridge Inventory (NBI) Statistics
  • 390Number of bridges
  • 8,819ft / 2,688mTotal length
  • $232,892,000Total costs
  • 12,462,950Total average daily traffic
  • 315,148Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Norfolk
  • No street view available for this location

New bridges in Norfolk, VA - historical statistics
  • New bridges - historical statistics
  • 21930-1939
  • 31940-1949
  • 151950-1959
  • 1191960-1969
  • 861970-1979
  • 511980-1989
  • 901990-1999
  • 62000-2009
  • 162010-2019
  • 22020-2022
Reconstructed bridges in Norfolk, VA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 81980-1989
  • 181990-1999
  • 32000-2009
  • 02010-2019
  • 12020-2022
Average Bridge Truck Traffic in Norfolk, VA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.7%Very good
  • 30.6%Good
  • 49.7%Satisfactory
  • 16.9%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.1%Very good
  • 21.3%Good
  • 46.4%Satisfactory
  • 25.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.7%Very good
  • 22.4%Good
  • 39.9%Satisfactory
  • 35.0%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 27.8%Very good
  • 44.4%Good
  • 22.2%Satisfactory
  • 5.6%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 1VALP79,  Location: EAST OF I-564 AT 3RD AVE. (Lat: 36.938111,  Lng: -76.301861),  Route carried "on" structure: ServiceOther road ,  Year Built: 1952,  Status: Open,  Structure Length: 0.83m (2.72ft),  Average Daily Traffic: 20 (year 2010),  Truck Traffic: 10%,  Average Future Daily Traffic: 25 (year 2040),  Design Load: HS 20,  Features Intersected: BOUSH CREEK,  Facility Carried by Structure: PATROL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Navy/Marines,  Approaching Roadway Width: 9.3m (30.5ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.83m (2.72ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $100,000,  Roadway Improvement Cost: $24,000,  Total Project Cost: $124,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 20764,  Location: 0.17 fr Curlew/0.27 to 13 (Lat: 36.843158,  Lng: -76.213211),  Route carried "on" structure: ServiceCounty highway F135,  Year Built: 1967,  Status: Open,  Structure Length: 9.20m (30.18ft),  Average Daily Traffic: 4,125 (year 1989),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,500 (year 2034),  Design Load: HS 20+Mod,  Features Intersected: IS 264 & Collector Roads,  Facility Carried by Structure: Frontage Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 16,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 20766,  Location: 0.10THOLE ST/0.20DEAD END (Lat: 36.904036,  Lng: -76.257681),  Route carried "on" structure: ServiceCity street ,  Year Built: 1967,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 200 (year 1990),  Truck Traffic: 25%,  Average Future Daily Traffic: 400 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: N BR LAFAYETTE RIVER,  Facility Carried by Structure: ROUTE 0000
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 43.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 20767,  Location: 0.20 TO 165/ 0.30NOF APOR (Lat: 36.886878,  Lng: -76.210300),  Route carried "on" structure: City street ,  Year Built: 1944,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 2.93m (9.61ft),  Average Daily Traffic: 9,300 (year 2012),  Truck Traffic: 15%,  Average Future Daily Traffic: 37,200 (year 2028),  Design Load: HS 20,  Features Intersected: NORFOLK WAT. SUPPLY CAN,  Facility Carried by Structure: ROBIN HOOD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 71.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Bridge Improvement Cost: $562,000,  Roadway Improvement Cost: $56,000,  Total Project Cost: $843,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 20768,  Location: 00.27 MILES FROM RTE. 460 (Lat: 36.950392,  Lng: -76.259325),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Open,  Structure Length: 2.59m (8.50ft),  Average Daily Traffic: 5,046 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,067 (year 2040),  Design Load: HS 20,  Features Intersected: TIDEWATER DRIVE_(RTE.168,  Facility Carried by Structure: 1ST VIEW STEET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 48.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $400,000,  Roadway Improvement Cost: $40,000,  Total Project Cost: $600,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 2077,  Location: 00.45 MILES FROM RTE. 460 (Lat: 36.953150,  Lng: -76.258967),  Route carried "on" structure: City street ,  Year Built: 1956,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 7,519 (year 1990),  Truck Traffic: 10%,  Average Future Daily Traffic: 9,000 (year 2028),  Design Load: HS 20,  Features Intersected: TIDEWATER DRIVE (RTE.168,  Facility Carried by Structure: GOVERNMT AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 45.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $340,000,  Roadway Improvement Cost: $34,000,  Total Project Cost: $510,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 20773,  Location: 0.75 38TH ST/0.50 TO 337 (Lat: 36.890756,  Lng: -76.295261),  Route carried "on" structure: City street ,  Year Built: 1978,  Status: Open,  Structure Length: 15.30m (50.20ft),  Average Daily Traffic: 6,825 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 9,300 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Colley Bay,  Facility Carried by Structure: Colley Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 70.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 20774,  Location: Ramp to Tidewater Drive (Lat: 36.844594,  Lng: -76.279283),  Route carried "on" structure: Ramp State highway 337,  Year Built: 1972,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 12,015 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 7,000 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: Adj to Mainline Br 2858
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 20775,  Location: 0.60 TO 165 /0.00NORF-AIR (Lat: 36.897761,  Lng: -76.214861),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 28.53m (93.60ft),  Average Daily Traffic: 11,873 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 13,598 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LAKE WHITEHURST,  Facility Carried by Structure: NORVIEW AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 18,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 76.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 54.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 20776,  Location: 0.10GRANBY ST0.90TIDEWTR (Lat: 36.888950,  Lng: -76.274922),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 30.24m (99.21ft),  Average Daily Traffic: 8,705 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,576 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: N. BRANCH LAFAYETTE RV.,  Facility Carried by Structure: WILLOW WOOD DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 15,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 91.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 70.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2020,  Underwater Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20777,  Location: 0.40 TO 337 /0.50 TO 165 (Lat: 36.911097,  Lng: -76.298439),  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 9.02m (29.59ft),  Average Daily Traffic: 1,146 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,261 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BR LAFFAYETTE RIVER,  Facility Carried by Structure: N SHORE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 38.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 9.14m (29.99ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2021,  Underwater Inspection Date: March 2021,  Bridge Improvement Cost: $900,000,  Roadway Improvement Cost: $90,000,  Total Project Cost: $1,350,000 ( Estimate for 2018),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20778,  Location: 0.20 TO 337 /0.70 TO 165 (Lat: 36.912742,  Lng: -76.301728),  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 6.43m (21.10ft),  Average Daily Traffic: 1,146 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,261 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BR LAFAYETTE RIVER,  Facility Carried by Structure: N SHORE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 37.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 6.71m (22.01ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: March 2021,  Bridge Improvement Cost: $660,000,  Roadway Improvement Cost: $66,000,  Total Project Cost: $990,000 ( Estimate for 2014),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20781,  Location: 0.20IND RV RD0.80STATO S (Lat: 36.831822,  Lng: -76.278275),  Route carried "on" structure: City street 407,  Year Built: 1985,  Status: Open,  Structure Length: 48.01m (157.51ft),  Average Daily Traffic: 3,702 (year 1990),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,000 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: NS Railway,  Facility Carried by Structure: Berkley Ave. EBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 17,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 75.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 58.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20782,  Location: 0.20IND RV RD0.80STATO S (Lat: 36.832061,  Lng: -76.278103),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 46.02m (150.98ft),  Average Daily Traffic: 3,702 (year 1990),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,000 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: NS Railway,  Facility Carried by Structure: Berkley Ave. WBL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 16,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 75.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 58.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 46.02m (150.98ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $6,000,000,  Roadway Improvement Cost: $600,000,  Total Project Cost: $6,600,000 ( Estimate for 2015),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2079,  Location: 0.24 MI NORTH INT IS 264 (Lat: 36.841125,  Lng: -76.210147),  Route carried "on" structure: US 13,  Year Built: 1943,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 5.76m (18.90ft),  Average Daily Traffic: 41,835 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 58,569 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CNW RAILWAY & CURLEW DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.564,  Lanes on structure: 10,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 44.5m (146.0ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 44.5m (146.0ft),  Out-to-Out Width: 45.4m (149.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 46.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 20793,  Location: 0.30 MI.FR.INT.RTE. IS64 (Lat: 36.846008,  Lng: -76.191000),  Route carried "on" structure: Interstate 264,  Year Built: 1967,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 101,413 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 111,554 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Route 165 Kempsville Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.260,  Lanes on structure: 8,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 36.3m (119.1ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 36.3m (119.1ft),  Out-to-Out Width: 37.9m (124.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20795,  Location: 0.30 MI.FR.INT.RTE. IS 64 (Lat: 36.845681,  Lng: -76.190975),  Route carried "on" structure: Interstate 264,  Year Built: 1967,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 101,649 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 134,284 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Route 165 Kempsville Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.260,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.3m (63.3ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 19.9m (65.3ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.40m (21.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $5,000,000,  Roadway Improvement Cost: $500,000,  Total Project Cost: $5,600,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 20797,  Location: 0.72 MI.FR.INT.RTE. IS 64 (Lat: 36.845831,  Lng: -76.183503),  Route carried "on" structure: Interstate 264,  Year Built: 1967,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 203,062 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 223,368 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Route 403 Newtown Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.882,  Lanes on structure: 13,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 68.9m (226.0ft),  Skew: 33 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 66.6m (218.5ft),  Out-to-Out Width: 69.4m (227.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.32m (24.02ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $6,000,000,  Roadway Improvement Cost: $600,000,  Total Project Cost: $6,630,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 20804,  Location: 0.61 TO 460A/0.70TO 337WB (Lat: 36.853889,  Lng: -76.297644),  Route carried "on" structure: US 58,  Year Built: 1962,  Status: Open,  Structure Length: 20.79m (68.21ft),  Average Daily Traffic: 30,721 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 33,793 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SMITH CREEK @ THE HAGUE,  Facility Carried by Structure: BRAMBLETON AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.311,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 49.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 21.34m (70.01ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2020,  Underwater Inspection Date: May 2021,  Bridge Improvement Cost: $5,250,000,  Roadway Improvement Cost: $525,000,  Total Project Cost: $7,875,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 20805,  Location: MIDTOWN TUNNEL; NORFOLK (Lat: 36.864364,  Lng: -76.306244),  Route carried "on" structure: US 58,  Year Built: 1962,  Status: Open,  Structure Length: 6.68m (21.92ft),  Average Daily Traffic: 5,598 (year 2014),  Average Future Daily Traffic: 7,032 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: US 58 & SR 337 ALT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.824,  Lanes on structure: 4,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Maintenance Responsibility: Private,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 47.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.03m (0.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $1,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $5,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 20809,  Location: 0.54 TO 166 /0.65 TO 170 (Lat: 36.910192,  Lng: -76.186622),  Route carried "on" structure: US 60,  Year Built: 1984,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 20,885 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 29,239 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LAKE WHITEHURST,  Facility Carried by Structure: SHORE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 27.433,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 40.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 24.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 20813,  Location: IS 64-264 INTERCHANGE (Lat: 36.846139,  Lng: -76.198514),  Route carried "on" structure: Ramp Interstate 64,  Year Built: 1985,  Status: Open,  Structure Length: 37.89m (124.31ft),  Average Daily Traffic: 23,651 (year 2020),  Average Future Daily Traffic: 28,878 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: IS 264 WBL; 64 & Ramps
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 16,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 56.4m (185.0ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 72.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 20815,  Location: 0.84 MIles from Route 168 (Lat: 36.903206,  Lng: -76.242942),  Route carried "on" structure: Interstate 64,  Year Built: 1965,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 3.67m (12.04ft),  Average Daily Traffic: 57,221 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 80,109 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Sewells Point Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 449.136,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.66m (12.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $500,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $750,000 ( Estimate for 2015),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 20817,  Location: 0.17 Miles from Route 194 (Lat: 36.903533,  Lng: -76.242983),  Route carried "on" structure: Interstate 64,  Year Built: 1965,  Status: Open,  Structure Length: 3.67m (12.04ft),  Average Daily Traffic: 53,424 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 74,794 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Sewells Point Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 449.088,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.81m (12.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $500,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $800,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 20819,  Location: 1.02 MI.FR.RTE. 168 (Lat: 36.903114,  Lng: -76.239897),  Route carried "on" structure: Interstate 64,  Year Built: 1965,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 57,221 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 80,109 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR 194 Chesapeake Blvd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 449.394,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20821,  Location: 0.98 MI.FR.RTE. 247 (Lat: 36.903450,  Lng: -76.239944),  Route carried "on" structure: Interstate 64,  Year Built: 1965,  Status: Open,  Structure Length: 5.24m (17.19ft),  Average Daily Traffic: 53,424 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 74,794 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR 194 Chesapeake Blvd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 449.345,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20823,  Location: 2.08 Miles from Route 460 (Lat: 36.950250,  Lng: -76.265339),  Route carried "on" structure: Interstate 64,  Year Built: 1975,  Status: Open,  Structure Length: 5.46m (17.91ft),  Average Daily Traffic: 34,478 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 48,269 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Mason Creek Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 442.314,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20827,  Location: 1.13 MI.FR.INT.RTE. 247 (Lat: 36.882281,  Lng: -76.216247),  Route carried "on" structure: Interstate 64,  Year Built: 1966,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 62,099 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 86,939 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Robin Hood Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 452.824,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20829,  Location: 1.13 MI.TO INT.RTE. 247 (Lat: 36.882556,  Lng: -76.216064),  Route carried "on" structure: Interstate 64,  Year Built: 1966,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 58,247 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 81,546 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Robin Hood Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 452.724,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.81m (12.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,200,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $1,500,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20831,  Location: 0.69 MI.FR.INT.RTE. 247 (Lat: 36.884536,  Lng: -76.223589),  Route carried "on" structure: Interstate 64,  Year Built: 1965,  Status: Open,  Structure Length: 3.79m (12.43ft),  Average Daily Traffic: 62,099 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 86,939 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Azalea Garden Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 452.081,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 59.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 20833,  Location: 1.60 MI.FR.INT.RTE. 13 (Lat: 36.884825,  Lng: -76.223417),  Route carried "on" structure: Interstate 64,  Year Built: 1966,  Status: Open,  Structure Length: 3.79m (12.43ft),  Average Daily Traffic: 58,247 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 81,546 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: Azalea Garden Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 452.032,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.3m (53.5ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20835,  Location: 2.19 MI FR INT. SR 194 (Lat: 36.881686,  Lng: -76.214317),  Route carried "on" structure: Interstate 64,  Year Built: 1966,  Status: Open,  Structure Length: 7.71m (25.30ft),  Average Daily Traffic: 52,492 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 73,489 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR 165 Military Highway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 452.950,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 20837,  Location: 2.19 MI TO INT. SR 194 (Lat: 36.882111,  Lng: -76.214625),  Route carried "on" structure: Interstate 64,  Year Built: 1966,  Status: Open,  Structure Length: 7.98m (26.18ft),  Average Daily Traffic: 58,247 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 81,546 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR 165 Military Highway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 452.853,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.99m (26.21ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $2,000,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $2,500,000 ( Estimate for 2014),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 20839,  Location: 2.00 MI.FR.RTE. 460 (Lat: 36.947236,  Lng: -76.266061),  Route carried "on" structure: Interstate 64,  Year Built: 1975,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 34,478 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 48,269 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: First View Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 442.652,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 59.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.27m (17.29ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $60,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $85,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20841,  Location: 0.95 MI. FR. INT. SR 165 (Lat: 36.906508,  Lng: -76.256786),  Route carried "on" structure: Interstate 64,  Year Built: 1967,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 54,724 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 76,614 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR 168 Tidewater Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 447.753,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.2m (66.3ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 20843,  Location: 1.03 MI. TO INT. SR 194 (Lat: 36.907267,  Lng: -76.256750),  Route carried "on" structure: Interstate 64,  Year Built: 1967,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 50,608 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 70,851 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR 168 Tidewater Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 447.672,  Lanes on structure: 5,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.8m (78.1ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 20845,  Location: 0.17 MI FROM INT SR 168 (Lat: 36.904772,  Lng: -76.254478),  Route carried "on" structure: Interstate 64,  Year Built: 1967,  Status: Open,  Structure Length: 4.23m (13.88ft),  Average Daily Traffic: 54,724 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 76,614 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR 168 NBL Ramp
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 448.058,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.2m (59.7ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 20847,  Location: Tidewater Drive Inter. (Lat: 36.903869,  Lng: -76.254603),  Route carried "on" structure: Ramp Interstate 64,  Year Built: 1967,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 5,187 (year 2020),  Average Future Daily Traffic: 7,262 (year 2040),  Design Load: HS 20,  Features Intersected: Trib Lafayette River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.241,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 78.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 2085,  Location: 2.00 Miles to Route 460 (Lat: 36.947125,  Lng: -76.266358),  Route carried "on" structure: Interstate 64,  Year Built: 1975,  Status: Open,  Structure Length: 5.27m (17.29ft),  Average Daily Traffic: 39,723 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 55,612 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: First View Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 442.475,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay