Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Wilson, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 198Number of bridges
  • 2,165ft / 660mTotal length
  • 1,920,346Total average daily traffic
  • 331,217Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Wilson
  • No street view available for this location

New bridges in Wilson, NC - historical statistics
  • New bridges - historical statistics
  • 81920-1929
  • 21930-1939
  • 31940-1949
  • 161950-1959
  • 71960-1969
  • 421970-1979
  • 101980-1989
  • 311990-1999
  • 682000-2009
  • 112010-2019
Reconstructed bridges in Wilson, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11930-1939
  • 21940-1949
  • 01950-1959
  • 21960-1969
  • 21970-1979
  • 01980-1989
  • 21990-1999
Average Bridge Daily Traffic in Wilson, NC
Average Bridge Truck Traffic in Wilson, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.0%Very good
  • 55.4%Good
  • 26.7%Satisfactory
  • 10.9%Fair
  • 2.0%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 12.9%Very good
  • 55.4%Good
  • 15.8%Satisfactory
  • 14.9%Fair
  • 1.0%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.9%Very good
  • 57.4%Good
  • 19.8%Satisfactory
  • 14.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 3.7%Very good
  • 60.5%Good
  • 21.0%Satisfactory
  • 14.8%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 24.1%Good
  • 41.4%Satisfactory
  • 34.5%Fair
Find on map >>   Show street view

Structure Number: 1950221,  Location: 0.2 MI. E. JCT. SR1163 (Lat: 35.717361,  Lng: -77.911042),  Route carried "on" structure: State highway 1192,  Year Built: 1975,  Status: Open,  Structure Length: 10.88m (35.70ft),  Average Daily Traffic: 15,500 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 31,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CSX RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.3m (56.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 36.5m (119.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 18.5m (60.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 69.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1950226,  Location: 0.7 MI. E. JCT. NC58 (Lat: 35.678922,  Lng: -77.847300),  Route carried "on" structure: US 264,  Year Built: 1985,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 20,500 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 41,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TOISNET SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1950229,  Location: 0.3 MI.E. JCT.SR1186 (Lat: 35.722397,  Lng: -77.920294),  Route carried "on" structure: State highway 1184,  Year Built: 1988,  Status: Open,  Structure Length: 4.32m (14.17ft),  Average Daily Traffic: 11,000 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 22,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CAROLINA & NW RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 15.6m (51.2ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 195023,  Location: 1.0 MI.W.NC91 (Lat: 35.668389,  Lng: -77.821517),  Route carried "on" structure: US 264,  Year Built: 1987,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 10,250 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 20,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 49.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2020,  Underwater Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1950236,  Location: 0.4 MI.W. OF JCT.SR1001 (Lat: 35.727289,  Lng: -78.008028),  Route carried "on" structure: State highway 1136,  Year Built: 1997,  Status: Open,  Structure Length: 7.19m (23.59ft),  Average Daily Traffic: 3,400 (year 2013),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,800 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: I795
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1950237,  Location: 0.2 MI. S. JCT. US264 (Lat: 35.760633,  Lng: -77.993511),  Route carried "on" structure: State highway 1157,  Year Built: 1997,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 4,700 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 9,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLOOMERY SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 1950238,  Location: 0.2 MI. S. JCT.US264 (Lat: 35.760406,  Lng: -77.993650),  Route carried "on" structure: State highway 1157,  Year Built: 1997,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 4,500 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 9,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLOOMERY SWAMP OV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2021,  Underwater Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 1950239,  Location: 0.8 MI. S. JCT. SR1163 (Lat: 35.696442,  Lng: -77.946992),  Route carried "on" structure: State highway 1165,  Year Built: 1997,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 12,000 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 24,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WIGGINS MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 195024,  Location: AT JCT OF NC42&US264BYP (Lat: 35.710889,  Lng: -77.999733),  Route carried "on" structure: State highway 42,  Year Built: 2002,  Status: Open,  Structure Length: 7.31m (23.98ft),  Average Daily Traffic: 11,500 (year 2018),  Truck Traffic: 8%,  Average Future Daily Traffic: 23,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-795, US264
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 42),  Owner: State Highway Agency,  Approaching Roadway Width: 25.2m (82.7ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 37.1m (121.7ft),  Curb-To-Curb Width: 23.9m (78.4ft),  Out-to-Out Width: 24.9m (81.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 87.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950241,  Location: .5 MI. E. OF JCT. NC42 (Lat: 35.708367,  Lng: -77.995697),  Route carried "on" structure: Interstate 795,  Year Built: 2002,  Status: Open,  Structure Length: 24.71m (81.07ft),  Average Daily Traffic: 15,750 (year 2018),  Truck Traffic: 23%,  Average Future Daily Traffic: 31,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CONTENTNEA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.344,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950242,  Location: .5 MI. E. JCT. NC42 (Lat: 35.708139,  Lng: -77.995728),  Route carried "on" structure: Interstate 795,  Year Built: 2002,  Status: Open,  Structure Length: 24.68m (80.97ft),  Average Daily Traffic: 12,500 (year 2013),  Truck Traffic: 23%,  Average Future Daily Traffic: 25,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CONTENTNEA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950243,  Location: .45 MI. S. JCT SR 42 (Lat: 35.706825,  Lng: -77.992550),  Route carried "on" structure: State highway 1162,  Year Built: 2002,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 3,300 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 6,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-795
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 34.7m (113.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950244,  Location: 0.2 MI. N. JCT. SR1164 (Lat: 35.696753,  Lng: -77.975172),  Route carried "on" structure: State highway 1163,  Year Built: 2002,  Status: Open,  Structure Length: 6.30m (20.67ft),  Average Daily Traffic: 2,200 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264 BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.3m (102.7ft),  Curb-To-Curb Width: 14.4m (47.2ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950245,  Location: 0.6 MI. E. OF JCT. SR1164 (Lat: 35.686994,  Lng: -77.966014),  Route carried "on" structure: State highway 1103,  Year Built: 2002,  Status: Open,  Structure Length: 8.50m (27.89ft),  Average Daily Traffic: 1,500 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-795/US264BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 42.9m (140.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 60.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950246,  Location: @JCT. OF US264BYP & US301 (Lat: 35.679272,  Lng: -77.952544),  Route carried "on" structure: Bypass US 264,  Year Built: 2002,  Status: Open,  Structure Length: 6.33m (20.77ft),  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 23,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US301
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.6m (103.7ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 82.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950247,  Location: 0.5 MI.E. JCT. I-795 (Lat: 35.679033,  Lng: -77.952678),  Route carried "on" structure: US 117,  Year Built: 2002,  Status: Open,  Structure Length: 6.33m (20.77ft),  Average Daily Traffic: 11,750 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 23,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US301
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.106,  Lanes on structure: 3,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 17),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 31.6m (103.7ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 83.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1950248,  Location: 0.5 MI. W. JCT. SR1612 (Lat: 35.675797,  Lng: -77.935219),  Route carried "on" structure: US 264,  Year Built: 2003,  Status: Open,  Structure Length: 6.58m (21.59ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CSX R/R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.441,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.8m (97.8ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1950249,  Location: .5 MI. W. SR1612 (Lat: 35.675600,  Lng: -77.935547),  Route carried "on" structure: US 264,  Year Built: 2003,  Status: Open,  Structure Length: 6.70m (21.98ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CSX RAIL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.441,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.7m (100.7ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 195025,  Location: .5 MI. W. JCT. SR1606 (Lat: 35.675550,  Lng: -77.933447),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1612, CSX R/R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.472,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950251,  Location: 4.4 MI. W. NC58 (Lat: 35.675328,  Lng: -77.933572),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 7.28m (23.88ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1612, CSX R/R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.472,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950252,  Location: .5 MI. W. OF JCT. SR1606 (Lat: 35.674406,  Lng: -77.912675),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 13.10m (42.98ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CONTENTNEA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950253,  Location: .5 MI. W. SR1606 (Lat: 35.674133,  Lng: -77.912456),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 13.10m (42.98ft),  Average Daily Traffic: 10,500 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 21,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CONTENTNEA CR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.020,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950254,  Location: 0.9 MI. N. JCT. SR1606 (Lat: 35.673919,  Lng: -77.906811),  Route carried "on" structure: State highway 1606,  Year Built: 2002,  Status: Open,  Structure Length: 6.21m (20.37ft),  Average Daily Traffic: 2,300 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.1m (98.8ft),  Curb-To-Curb Width: 14.3m (46.9ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950255,  Location: 1 MI. N. JCT. SR1622 (Lat: 35.668311,  Lng: -77.879136),  Route carried "on" structure: State highway 1602,  Year Built: 2003,  Status: Open,  Structure Length: 7.16m (23.49ft),  Average Daily Traffic: 2,400 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264 BYP.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 65.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950256,  Location: 1 MILE WEST OF NC-58 (Lat: 35.668986,  Lng: -77.873169),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 5.42m (17.78ft),  Average Daily Traffic: 9,750 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 19,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORFOLK SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 84.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950257,  Location: 1 MILE WEST OF NC58 (Lat: 35.668797,  Lng: -77.872997),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 5.51m (18.08ft),  Average Daily Traffic: 9,750 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 19,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CAROLINA COASTAL RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.7m (90.9ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950258,  Location: 0.6 MI. N. JCT. SR1622 (Lat: 35.674586,  Lng: -77.857858),  Route carried "on" structure: State highway 58,  Year Built: 2003,  Status: Open,  Structure Length: 6.43m (21.10ft),  Average Daily Traffic: 3,750 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264 BYP.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.0m (101.7ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950259,  Location: 0.6 MI. N. JCT. SR1622 (Lat: 35.674503,  Lng: -77.858069),  Route carried "on" structure: State highway 58,  Year Built: 2003,  Status: Open,  Structure Length: 6.33m (20.77ft),  Average Daily Traffic: 3,600 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264 BYP.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.7m (100.7ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 195026,  Location: 086 MI. W. OF SR1602 (Lat: 35.671806,  Lng: -77.894458),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 6.73m (22.08ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HOMINY SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 88.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950261,  Location: 0.86 MI. W. JCT. SR1602 (Lat: 35.671592,  Lng: -77.894533),  Route carried "on" structure: Bypass US 264,  Year Built: 2003,  Status: Open,  Structure Length: 6.73m (22.08ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HOMINY SWAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.2m (72.8ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 88.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950262,  Location: 0.25 MI. S. JCT. NC42 (Lat: 35.709889,  Lng: -77.998358),  Route carried "on" structure: Interstate 795,  Year Built: 2002,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 34,500 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 69,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MILL BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.192,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 23.1m (75.8ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 1950263,  Location: 300 FT. W. JCT. US264BYP (Lat: 35.710517,  Lng: -78.001297),  Route carried "on" structure: State highway 42,  Year Built: 2002,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 11,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 22,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: MILL BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.9m (58.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 1950264,  Location: 150 FT. S. JCT. NC42 (Lat: 35.711319,  Lng: -78.002306),  Route carried "on" structure: Ramp Interstate 795,  Year Built: 2002,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 7,875 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 15,750 (year 2040),  Design Load: H 10,  Features Intersected: MILL BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 70.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2022,  Underwater Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 1950265,  Location: JCT. OF US264ALT & US264 (Lat: 35.761725,  Lng: -78.028458),  Route carried "on" structure: Alternate US 264,  Year Built: 1998,  Status: Open,  Structure Length: 6.30m (20.67ft),  Average Daily Traffic: 5,500 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.972,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.8m (74.8ft),  Curb-To-Curb Width: 27.9m (91.5ft),  Out-to-Out Width: 28.9m (94.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950266,  Location: 0.5 MI.W.JCT.I95 (Lat: 35.751894,  Lng: -78.023764),  Route carried "on" structure: US 264,  Year Built: 1998,  Status: Open,  Structure Length: 4.90m (16.08ft),  Average Daily Traffic: 9,000 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 18,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORFOLK/SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.186,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.2m (59.7ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950267,  Location: 0.5 MI.W.JCT.I95 (Lat: 35.751825,  Lng: -78.023433),  Route carried "on" structure: US 264,  Year Built: 1998,  Status: Open,  Structure Length: 4.90m (16.08ft),  Average Daily Traffic: 11,250 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 22,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NORFOLK/SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.186,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.2m (59.7ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1950268,  Location: JCT. OF US264 & I-95 (Lat: 35.734075,  Lng: -78.011681),  Route carried "on" structure: Interstate 795,  Year Built: 1998,  Status: Open,  Structure Length: 17.73m (58.17ft),  Average Daily Traffic: 15,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 31,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 36.271,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950269,  Location: JCT. OF I95,I795,& US264 (Lat: 35.734331,  Lng: -78.011478),  Route carried "on" structure: Interstate 795,  Year Built: 1998,  Status: Open,  Structure Length: 17.98m (58.99ft),  Average Daily Traffic: 15,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 31,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.582,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 13.8m (45.3ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1950287,  Location: 0.35 MI. N. JCT. SR1544 (Lat: 35.672350,  Lng: -77.805275),  Route carried "on" structure: Alternate US 264,  Year Built: 2001,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 2,200 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,400 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US264
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.2m (95.8ft),  Curb-To-Curb Width: 17.3m (56.8ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1950288,  Location: .7 MI. S. OF SR1100 (Lat: 35.666944,  Lng: -77.956625),  Route carried "on" structure: Interstate 795,  Year Built: 2006,  Status: Open,  Structure Length: 4.87m (15.98ft),  Average Daily Traffic: 8,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 17,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CSX R/R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.553,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 14.4m (47.2ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 86.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1950289,  Location: .7 OF A MI. S. OF SR1100 (Lat: 35.667028,  Lng: -77.956419),  Route carried "on" structure: Interstate 795,  Year Built: 2006,  Status: Open,  Structure Length: 4.87m (15.98ft),  Average Daily Traffic: 8,750 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 17,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CSX RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.553,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 95),  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 195029,  Location: 0.1 MI. S. JCT. US301 (Lat: 35.667267,  Lng: -77.955794),  Route carried "on" structure: Ramp Interstate 795,  Year Built: 2006,  Status: Open,  Structure Length: 5.02m (16.47ft),  Average Daily Traffic: 3,125 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 6,250 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CSX R/R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.613,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.5m (73.8ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Wilson, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.