Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Ironton, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 39Number of bridges
  • 741ft / 226mTotal length
  • $177,000Total costs
  • 172,661Total average daily traffic
  • 14,013Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Ironton
  • No street view available for this location

New bridges in Ironton, OH - historical statistics
  • New bridges - historical statistics
  • 21900-1909
  • 41930-1939
  • 31940-1949
  • 201960-1969
  • 11970-1979
  • 41990-1999
  • 22000-2009
  • 32010-2019
Reconstructed bridges in Ironton, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 11980-1989
  • 11990-1999
  • 22000-2009
Average Bridge Daily Traffic in Ironton, OH
Average Bridge Truck Traffic in Ironton, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 13.3%Very good
  • 26.7%Good
  • 46.7%Satisfactory
  • 6.7%Fair
  • 3.3%Poor
  • 3.3%Critical
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.3%Very good
  • 20.0%Good
  • 43.3%Satisfactory
  • 6.7%Fair
  • 3.3%Poor
  • 3.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 6.7%Very good
  • 40.0%Good
  • 36.7%Satisfactory
  • 16.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.8%Excellent
  • 19.0%Very good
  • 14.3%Good
  • 38.1%Satisfactory
  • 14.3%Fair
  • 9.5%Poor
Find on map >>   Show street view

Structure Number: 4400399,  Location: 0.23MI W OF SR 93 (Lat: 38.541581,  Lng: -82.680089),  Route carried "on" structure: US 52,  Year Built: 1960,  Status: Open,  Structure Length: 10.44m (34.25ft),  Average Daily Traffic: 6,277 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 8,712 (year 2035),  Design Load: HS 20,  Features Intersected: STORMS CK & LAWRENCE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.799,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.7m (94.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4400429,  Location: 0.23MI W OF SR 93 (Lat: 38.541439,  Lng: -82.680211),  Route carried "on" structure: US 52,  Year Built: 1960,  Status: Open,  Structure Length: 10.44m (34.25ft),  Average Daily Traffic: 6,277 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 8,712 (year 2035),  Design Load: HS 20,  Features Intersected: STORMS CK & LAWRENCE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.799,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.7m (94.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4400453,  Location: 0.12MI W OF SR 93 (Lat: 38.540319,  Lng: -82.678661),  Route carried "on" structure: US 52,  Year Built: 1960,  Status: Open,  Structure Length: 4.24m (13.91ft),  Average Daily Traffic: 6,277 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 8,712 (year 2035),  Design Load: HS 20,  Features Intersected: ABANDONED RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.976,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4400488,  Location: 0.12MI W OF SR 93 (Lat: 38.540189,  Lng: -82.678839),  Route carried "on" structure: US 52,  Year Built: 1960,  Status: Open,  Structure Length: 4.24m (13.91ft),  Average Daily Traffic: 6,277 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 8,712 (year 2035),  Design Load: HS 20,  Features Intersected: ABANDONED RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.976,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4400518,  Location: OVER SR 93 (Lat: 38.538989,  Lng: -82.677119),  Route carried "on" structure: US 52,  Year Built: 1960,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 7,691 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,675 (year 2035),  Design Load: HS 20,  Features Intersected: STATE ROUTE 93
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.169,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 16.3m (53.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4400542,  Location: SR 93 (Lat: 38.538861,  Lng: -82.677331),  Route carried "on" structure: US 52,  Year Built: 1962,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 7,691 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 10,675 (year 2035),  Design Load: HS 20,  Features Intersected: STATE ROUTE 93
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.169,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4400577,  Location: OVER SR 141 (Lat: 38.526350,  Lng: -82.664819),  Route carried "on" structure: US 52,  Year Built: 1962,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 9,947 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 13,806 (year 2035),  Design Load: HS 20,  Features Intersected: STATE ROUTE 141
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.939,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4400607,  Location: OVER SR 141 (Lat: 38.526239,  Lng: -82.665011),  Route carried "on" structure: US 52,  Year Built: 1962,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 9,947 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 13,806 (year 2035),  Design Load: HS 20,  Features Intersected: STATE ROUTE 141
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.939,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4400631,  Location: 0.95MI E OF SR 141 (Lat: 38.516261,  Lng: -82.652669),  Route carried "on" structure: US 52,  Year Built: 1962,  Status: Open,  Structure Length: 7.50m (24.61ft),  Average Daily Traffic: 10,788 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,974 (year 2035),  Design Load: HS 20,  Features Intersected: ABAN RR,CR 24 MADDYVILLE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.468,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4400666,  Location: 0.99 MI E OF SR 141 (Lat: 38.516350,  Lng: -82.653031),  Route carried "on" structure: US 52,  Year Built: 1962,  Status: Open,  Structure Length: 7.50m (24.61ft),  Average Daily Traffic: 10,788 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,974 (year 2035),  Design Load: HS 20,  Features Intersected: ABAN RR,CR 24 MADDYVILLE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.468,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 440069,  Location: 0.87MI W OF SR 243 (Lat: 38.514731,  Lng: -82.651900),  Route carried "on" structure: US 52,  Year Built: 1962,  Status: Open,  Structure Length: 11.19m (36.71ft),  Average Daily Traffic: 10,788 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,974 (year 2035),  Design Load: HS 20,  Features Intersected: ICE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.677,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 41.5m (136.2ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 440072,  Location: 0.87 MI W OF SR 243 (Lat: 38.514611,  Lng: -82.652081),  Route carried "on" structure: US 52,  Year Built: 1962,  Status: Open,  Structure Length: 11.19m (36.71ft),  Average Daily Traffic: 10,788 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,974 (year 2035),  Design Load: HS 20,  Features Intersected: ICE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.677,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 41.5m (136.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4401263,  Location: 2ND ST BETWN ADAMS /JEFF (Lat: 38.527211,  Lng: -82.683481),  Route carried "on" structure: State highway 93,  Year Built: 2016,  Status: Open,  Structure Length: 79.75m (261.65ft),  Average Daily Traffic: 10,300 (year 2008),  Truck Traffic: 4%,  Average Future Daily Traffic: 14,430 (year 2028),  Design Load: HL 93,  Features Intersected: OHIO RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.002,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.8m (48.6ft),  Navigation Control: Yes ( Vertical Clearance: 27.4m (89.9ft), Horizontal Clearance: 245.4m (805.1ft)),  Material/Design: Steel,  Design/Construction: Stayed Girder,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 6,  Length of Maximum Span: 274.3m (899.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 36.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 440136,  Location: 5.13 MI N OF US RT 52 (Lat: 38.575681,  Lng: -82.635889),  Route carried "on" structure: State highway 93,  Year Built: 1994,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 6,544 (year 2015),  Truck Traffic: 21%,  Average Future Daily Traffic: 9,083 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: NORRIS BR OF STORMS CREE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.293,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4401395,  Location: 8.56 KM N OF US 52 (Lat: 38.577869,  Lng: -82.637511),  Route carried "on" structure: State highway 93,  Year Built: 1995,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 6,544 (year 2015),  Truck Traffic: 21%,  Average Future Daily Traffic: 9,083 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: STORMS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.598,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4432223,  Location: .18 MI N OF IRONTON CORP (Lat: 38.541311,  Lng: -82.679450),  Route carried "on" structure: County highway C0022,  Year Built: 2013,  Status: Open,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 1,219 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,692 (year 2038),  Design Load: HL 93,  Features Intersected: STORMS CREEK,  Facility Carried by Structure: COUNTY ROAD 22
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.290,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.8m (97.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4435567,  Location: 0.27 MILES WEST OF SR 93 (Lat: 38.548831,  Lng: -82.662361),  Route carried "on" structure: County highway C0021,  Year Built: 1949,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 906 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,258 (year 2035),  Design Load: HS 20,  Features Intersected: STORMS CREEK,  Facility Carried by Structure: PORTER GAP ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.435,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4435656,  Location: 315 FT S OF CTY RD 22 (Lat: 38.570939,  Lng: -82.678311),  Route carried "on" structure: County highway C0021,  Year Built: 2006,  Status: Posted for load,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 906 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,258 (year 2035),  Design Load: HS 20,  Features Intersected: LITTLE STORMS CREEK,  Facility Carried by Structure: PORTER GAP ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.347,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Fair,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4435753,  Location: 1.10 MILES NORTH OF C0RP (Lat: 38.552061,  Lng: -82.675711),  Route carried "on" structure: County highway C0022,  Year Built: 1900,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 1,219 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,692 (year 2035),  Design Load: HS 20,  Features Intersected: LITTLE STORMS CREEK,  Facility Carried by Structure: COUNTY ROAD 22
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.770,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 7.62m (25.00ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $95,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $100,000,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4435796,  Location: 20 FT N OF TWP RD 203E (Lat: 38.558600,  Lng: -82.686769),  Route carried "on" structure: County highway C0022,  Year Built: 1935,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 246 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 341 (year 2035),  Design Load: H 15,  Features Intersected: LITTLE STORMS CREEK,  Facility Carried by Structure: COUNTY ROAD 22
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.187,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 5.6m (18.4ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Fair,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 7.32m (24.02ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $22,000,  Roadway Improvement Cost: $2,000,  Total Project Cost: $43,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4435974,  Location: 65 FT E OF CTY RD 181 (Lat: 38.514761,  Lng: -82.650050),  Route carried "on" structure: County highway C0024,  Year Built: 1978,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 1,350 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,874 (year 2035),  Design Load: H 15,  Features Intersected: BIG ICE CREEK,  Facility Carried by Structure: MADDYVILLE TPKA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.386,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4439996,  Location: 0.61 MI E OF SR 141 (Lat: 38.539569,  Lng: -82.619811),  Route carried "on" structure: County highway C0052,  Year Built: 1993,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 127 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 176 (year 2038),  Design Load: HS 20,  Features Intersected: SUGAR CREEK,  Facility Carried by Structure: COUNTY ROAD 52
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.982,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 90.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4451929,  Location: 0.12 MILES NORTH OF CR 21 (Lat: 38.573200,  Lng: -82.680000),  Route carried "on" structure: County highway T0179,  Year Built: 1938,  Status: Posted for load,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 215 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 298 (year 2035),  Features Intersected: LITTLE STORMS CREEK,  Facility Carried by Structure: TOWNSHIP ROAD 179
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 19.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4451953,  Location: 0.61 MILES NORTH OF CR 22 (Lat: 38.576969,  Lng: -82.675669),  Route carried "on" structure: County highway T0179,  Year Built: 1940,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 215 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 298 (year 2035),  Features Intersected: LITTLE STORMS CREEK,  Facility Carried by Structure: TOWNSHIP ROAD 179
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.982,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 7.01m (23.00ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $14,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $34,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4458508,  Location: 250 FT W OF TWP RD 179 (Lat: 38.582131,  Lng: -82.675619),  Route carried "on" structure: County highway T0271,  Year Built: 1997,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 96 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 133 (year 2038),  Design Load: HS 20,  Features Intersected: TRIB OF STORMS CREEK,  Facility Carried by Structure: TOWNSHIP ROAD 271
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.467,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.4m (11.2ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 84.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4460006,  Location: 266' N OF MARION PIKE (Lat: 38.499161,  Lng: -82.654669),  Route carried "on" structure: City street 3RDST,  Year Built: 1943,  Year Reconstructed: 1987,  Status: Posted for load,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 7,071 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,241 (year 2038),  Design Load: HS 15,  Features Intersected: ICE CREEK,  Facility Carried by Structure: 3RD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 18.5m (60.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4460014,  Location: 0.3 MI N JCT RAILROAD ST (Lat: 38.539931,  Lng: -82.690461),  Route carried "on" structure: City street 2NDST,  Year Built: 1936,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 14.68m (48.16ft),  Average Daily Traffic: 4,781 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,800 (year 2038),  Design Load: H 15,  Features Intersected: N & W RAILROAD,  Facility Carried by Structure: NORTH 2ND STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.391,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Truss - Deck,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 5,  Length of Maximum Span: 44.7m (146.7ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Critical Feature Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4460022,  Location: 390' S OF SYCAMORE ST (Lat: 38.545281,  Lng: -82.697669),  Route carried "on" structure: City street 2NDST,  Year Built: 1939,  Year Reconstructed: 1978,  Status: Posted for load,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 1,800 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,700 (year 2038),  Design Load: H 15,  Features Intersected: STORMS CREEK,  Facility Carried by Structure: NORTH 2ND STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.116,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.2m (76.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 19.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 4460057,  Location: 0.15 MI NORTH JCT ELM ST (Lat: 38.547761,  Lng: -82.693411),  Route carried "on" structure: City street 5THST,  Year Built: 1900,  Year Reconstructed: 1984,  Status: Posted for load,  Structure Length: 3.87m (12.70ft),  Average Daily Traffic: 100 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 139 (year 2038),  Design Load: HS 20,  Features Intersected: STORMS CREEK,  Facility Carried by Structure: NORTH 5TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.389,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.5m (123.0ft),  Curb-To-Curb Width: 4.9m (16.1ft),  Out-to-Out Width: 4.9m (16.1ft)

Condition: Deck: Critical,  Superstructure: Serious,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 22.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Critical Feature Inspection Date: July 2020,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4460065,  Location: 450' E OF LORAIN ST (Lat: 38.510289,  Lng: -82.655511),  Route carried "on" structure: City street CEMRD,  Year Built: 2003,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 300 (year 2000),  Truck Traffic: 5%,  Average Future Daily Traffic: 416 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: ICE CREEK,  Facility Carried by Structure: S 9TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.993,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4400399,  Location: 0.23MI W OF SR 93 (Lat: 38.541581,  Lng: -82.680089),  Route carried "under" structure: County highway 22,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 1,219 (year 2015),  Truck Traffic: 2%,  Features Intersected: WEST BOUND US 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 12.19m (39.99ft),  Kilometerpoint: 0.676,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.7m (94.2ft)

Find on map >>   Show street view

Structure Number: 4400429,  Location: 0.23MI W OF SR 93 (Lat: 38.541439,  Lng: -82.680211),  Route carried "under" structure: County highway 22,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 1,219 (year 2015),  Truck Traffic: 2%,  Features Intersected: EAST BOUND USR 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 12.19m (39.99ft),  Kilometerpoint: 0.644,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.7m (94.2ft)

Find on map >>   Show street view

Structure Number: 4400518,  Location: OVER SR 93 (Lat: 38.538989,  Lng: -82.677119),  Route carried "under" structure: State highway 93,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 8,657 (year 2015),  Truck Traffic: 4%,  Features Intersected: W BOUND US 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 4.40m (14.44ft),  Kilometerpoint: 0.177,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 4400542,  Location: SR 93 (Lat: 38.538861,  Lng: -82.677331),  Route carried "under" structure: State highway 93,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 8,657 (year 2015),  Truck Traffic: 4%,  Features Intersected: EAST BOUND US 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 4400577,  Location: OVER SR 141 (Lat: 38.526350,  Lng: -82.664819),  Route carried "under" structure: State highway 141,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 1,317 (year 2015),  Truck Traffic: 3%,  Features Intersected: WEST BOUND US 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.274,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>   Show street view

Structure Number: 4400607,  Location: OVER SR 141 (Lat: 38.526239,  Lng: -82.665011),  Route carried "under" structure: State highway 141,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 1,317 (year 2015),  Truck Traffic: 3%,  Features Intersected: EAST BOUND US 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 0.241,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>   Show street view

Structure Number: 4400631,  Location: 0.95MI E OF SR 141 (Lat: 38.516261,  Lng: -82.652669),  Route carried "under" structure: County highway 24,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 1,350 (year 2015),  Truck Traffic: 5%,  Features Intersected: WEST BOUND US 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 7.42m (24.34ft),  Kilometerpoint: 0.644,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 4400666,  Location: 0.99 MI E OF SR 141 (Lat: 38.516350,  Lng: -82.653031),  Route carried "under" structure: County highway 24,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 1,350 (year 2015),  Truck Traffic: 5%,  Features Intersected: EAST BOUND US 52,  Facility Carried by Structure: US 52
Minimum Vertical Clearance: 6.81m (22.34ft),  Kilometerpoint: 0.660,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 4401263,  Location: 2ND ST BETWN ADAMS /JEFF (Lat: 38.527211,  Lng: -82.683481),  Route carried "under" structure: City street FstSt,  Year Built: 2016,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2015),  Truck Traffic: 25%,  Features Intersected: SR93P,  Facility Carried by Structure: SR93P
Minimum Vertical Clearance: 6.40m (21.00ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stayed Girder,  Length of Maximum Span: 274.3m (899.9ft)

Discuss Ironton, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.