Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Reading, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 61Number of bridges
  • 1,030ft / 314mTotal length
  • $48,783,000Total costs
  • 1,123,446Total average daily traffic
  • 62,627Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Reading
  • No street view available for this location

New bridges in Reading, PA - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 61910-1919
  • 71920-1929
  • 61930-1939
  • 171950-1959
  • 161960-1969
  • 21970-1979
  • 41980-1989
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Reading, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21940-1949
  • 11950-1959
  • 11960-1969
  • 41970-1979
  • 01980-1989
  • 51990-1999
  • 22000-2009
  • 12010-2019
  • 12020-2022
Average Bridge Daily Traffic in Reading, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.2%Very good
  • 9.7%Good
  • 41.9%Satisfactory
  • 38.7%Fair
  • 6.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.1%Very good
  • 15.6%Good
  • 37.5%Satisfactory
  • 37.5%Fair
  • 6.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 18.8%Good
  • 37.5%Satisfactory
  • 34.4%Fair
  • 9.4%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 13.3%Good
  • 26.7%Satisfactory
  • 46.7%Fair
  • 13.3%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Very good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 4735,  Location: EXIT 10(3) PA. 724 (Lat: 40.298672,  Lng: -75.900917),  Route carried "on" structure: Interstate 176,  Year Built: 1962,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 11,200 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 12,811 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: PA 724(LR 147)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.893,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.70m (15.42ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $31,000,  Roadway Improvement Cost: $90,000,  Total Project Cost: $414,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4737,  Location: EXIT 10(3) PA. 724 (Lat: 40.298844,  Lng: -75.901186),  Route carried "on" structure: Interstate 176,  Year Built: 1962,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 10,976 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 14,093 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: PA 724(LR 147)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.913,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.80m (15.75ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $16,000,  Roadway Improvement Cost: $46,000,  Total Project Cost: $213,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4741,  Location: SCHUYLKILL AVE SB ONE-WAY (Lat: 40.342700,  Lng: -75.938900),  Route carried "on" structure: State highway 183,  Year Built: 1916,  Status: Open,  Structure Length: 2.38m (7.81ft),  Average Daily Traffic: 6,400 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,244 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK/SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.507,  Lanes on structure: 2,  Owner: Railroad,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Operating Rating: 88.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.10m (10.17ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: March 2020,  Other Special Inspection Date: March 2021,  Bridge Improvement Cost: $38,000,  Roadway Improvement Cost: $111,000,  Total Project Cost: $508,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4742,  Location: SCHUYLKILL AVE (Lat: 40.349889,  Lng: -75.943417),  Route carried "on" structure: State highway 183,  Year Built: 1924,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 26.70m (87.60ft),  Average Daily Traffic: 15,418 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 19,200 (year 2032),  Design Load: HS 20,  Features Intersected: SCHUYLKILL RIV;NSRC;ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.507,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 21,  Length of Maximum Span: 32.3m (106.0ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 21.10m (69.23ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Underwater Inspection Date: May 2021,  Bridge Improvement Cost: $340,000,  Roadway Improvement Cost: $1,002,000,  Total Project Cost: $4,593,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4744,  Location: SCHUYLKILL AVE. (Lat: 40.355978,  Lng: -75.948781),  Route carried "on" structure: State highway 183,  Year Built: 1957,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 12,380 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 15,870 (year 2032),  Design Load: HS 20,  Features Intersected: PA 12(LR 784& LR 06150)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.441,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.00m (9.84ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2019,  Bridge Improvement Cost: $15,000,  Roadway Improvement Cost: $43,000,  Total Project Cost: $197,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4773,  Location: US422 INTERCHANGE (Lat: 40.324122,  Lng: -75.933597),  Route carried "on" structure: US 422,  Year Built: 1963,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 33,526 (year 2022),  Truck Traffic: 9%,  Average Future Daily Traffic: 44,567 (year 2032),  Design Load: HS 20,  Features Intersected: SR 3222(LR148)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.794,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.3m (83.0ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 98.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.50m (11.48ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $17,000,  Roadway Improvement Cost: $51,000,  Total Project Cost: $234,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4775,  Location: READING BYPASS (Lat: 40.329847,  Lng: -75.939364),  Route carried "on" structure: US 422,  Year Built: 1964,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 66,986 (year 2022),  Truck Traffic: 10%,  Average Future Daily Traffic: 89,158 (year 2032),  Design Load: HS 20,  Features Intersected: WYOMISSING CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.048,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Inventory Rating: 99.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2018
Find on map >>   Show street view

Structure Number: 4781,  Location: PA12-US222/422 INTERCHNGE (Lat: 40.358417,  Lng: -75.944425),  Route carried "on" structure: State highway 12,  Year Built: 1951,  Status: Open,  Structure Length: 12.13m (39.80ft),  Average Daily Traffic: 66,640 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 79,095 (year 2032),  Design Load: HS 20,  Features Intersected: 222 SB,422 WB,CK,CITY ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 51.8m (169.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 13.10m (42.98ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $128,000,  Roadway Improvement Cost: $378,000,  Total Project Cost: $1,730,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4782,  Location: WARREN ST.BYPASS (Lat: 40.370861,  Lng: -75.928675),  Route carried "on" structure: State highway 12,  Year Built: 1957,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 23.77m (77.99ft),  Average Daily Traffic: 60,964 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 75,753 (year 2032),  Design Load: HS 20,  Features Intersected: SCHUYLKILL R.;RIVER RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.728,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 1,  Length of Maximum Span: 71.3m (233.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 24.30m (79.72ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2020,  Critical Feature Inspection Date: October 2020,  Underwater Inspection Date: August 2020,  Bridge Improvement Cost: $187,000,  Roadway Improvement Cost: $550,000,  Total Project Cost: $2,522,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4784,  Location: WARREN ST.BYPASS (Lat: 40.368556,  Lng: -75.935414),  Route carried "on" structure: State highway 12,  Year Built: 1957,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 61,665 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 67,138 (year 2032),  Design Load: HS 20,  Features Intersected: PRIVATE RDS(CAR-TECH.)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.615,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 26.1m (85.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 7.20m (23.62ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Bridge Improvement Cost: $44,000,  Roadway Improvement Cost: $130,000,  Total Project Cost: $595,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4785,  Location: PA61 INTERCHANGE (Lat: 40.369417,  Lng: -75.932694),  Route carried "on" structure: State highway 12,  Year Built: 1957,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 47,538 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 55,276 (year 2032),  Design Load: HS 20,  Features Intersected: SR 61(LR 160)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.101,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 23.6m (77.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 83.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.70m (12.14ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Bridge Improvement Cost: $21,000,  Roadway Improvement Cost: $61,000,  Total Project Cost: $279,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4851,  Location: READING BYPASS (Lat: 40.313058,  Lng: -75.921669),  Route carried "on" structure: US 422,  Year Built: 1963,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 63,844 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 74,964 (year 2032),  Design Load: HS 20,  Features Intersected: BRENTWOOD DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.907,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 20.0m (65.6ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.80m (15.75ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4852,  Location: CITY LINE,READING BYPASS (Lat: 40.312389,  Lng: -75.919753),  Route carried "on" structure: US 422,  Year Built: 1963,  Status: Open,  Structure Length: 21.34m (70.01ft),  Average Daily Traffic: 63,844 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 74,964 (year 2032),  Design Load: HS 20,  Features Intersected: SCHUYLKILL RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.395,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 1,  Length of Maximum Span: 44.8m (147.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Fair,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 22.00m (72.18ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: September 2020,  Critical Feature Inspection Date: September 2021,  Underwater Inspection Date: July 2020,  Other Special Inspection Date: September 2021,  Bridge Improvement Cost: $263,000,  Roadway Improvement Cost: $774,000,  Total Project Cost: $3,549,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 4853,  Location: READING BYPASS (Lat: 40.309364,  Lng: -75.908172),  Route carried "on" structure: US 422,  Year Built: 1963,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 63,844 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 74,964 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK/SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.518,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.4m (57.1ft),  Curb-To-Curb Width: 19.9m (65.3ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.00m (19.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $31,000,  Roadway Improvement Cost: $91,000,  Total Project Cost: $417,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4854,  Location: READING BYPASS (Lat: 40.308775,  Lng: -75.905931),  Route carried "on" structure: US 422,  Year Built: 1963,  Status: Open,  Structure Length: 19.39m (63.62ft),  Average Daily Traffic: 63,844 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 74,964 (year 2032),  Design Load: HS 20,  Features Intersected: SCHUY.RIVER,SERVICE RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.518,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 50.3m (165.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 20.00m (65.62ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Critical Feature Inspection Date: September 2021,  Underwater Inspection Date: December 2020,  Other Special Inspection Date: September 2021,  Bridge Improvement Cost: $135,000,  Roadway Improvement Cost: $398,000,  Total Project Cost: $1,825,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 5033,  Location: 4TH ST (ONE-WAY SB) (Lat: 40.343817,  Lng: -75.929589),  Route carried "on" structure: State highway ,  Year Built: 1916,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 5,633 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,328 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK SOUTHERN,  Facility Carried by Structure: SR 2003 (LR 06220)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.038,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 3.5m (11.5ft),  Right: 3.5m (11.5ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Bridge Improvement Cost: $28,000,  Roadway Improvement Cost: $81,000,  Total Project Cost: $373,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5035,  Location: BINGAMAN ST BRIDGE (Lat: 40.326150,  Lng: -75.932333),  Route carried "on" structure: US 222B,  Year Built: 1920,  Year Reconstructed: 1966,  Status: Open,  Structure Length: 44.99m (147.60ft),  Average Daily Traffic: 18,054 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,217 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK SOUTHERN RR,  Facility Carried by Structure: SR 2005 (LR 148)
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 13,  Number Of Approach Spans: 2,  Length of Maximum Span: 34.7m (113.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 45.70m (149.93ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: April 2020,  Underwater Inspection Date: October 2020,  Bridge Improvement Cost: $686,000,  Roadway Improvement Cost: $2,019,000,  Total Project Cost: $9,255,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5036,  Location: AT 61/222 BUS. SPLIT (Lat: 40.343647,  Lng: -75.927606),  Route carried "on" structure: Business US 222B,  Year Built: 1936,  Status: Posted for load,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 8,573 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 18,506 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK SOUTHERN RR,  Facility Carried by Structure: US 222 BUS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.338,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 23.1m (75.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 2.70m (8.86ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Other Special Inspection Date: May 2021,  Bridge Improvement Cost: $15,000,  Roadway Improvement Cost: $44,000,  Total Project Cost: $203,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 504,  Location: 7TH & WASHINGTON ST. (Lat: 40.336897,  Lng: -75.924000),  Route carried "on" structure: US 422B,  Year Built: 1882,  Year Reconstructed: 1964,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 13,380 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 13,296 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK/SOUTHERN RR,  Facility Carried by Structure: WASHING. ST(06233)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.584,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: Railroad,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 50.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.70m (8.86ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2019,  Bridge Improvement Cost: $19,000,  Roadway Improvement Cost: $55,000,  Total Project Cost: $252,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5048,  Location: WALNUT ST EB ONE-WAY (Lat: 40.338297,  Lng: -75.924197),  Route carried "on" structure: State highway ,  Year Built: 1926,  Year Reconstructed: 1953,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 8,768 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,120 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK/SOUTHERN RR,  Facility Carried by Structure: SR 2012 (LR 06208)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.660,  Lanes on structure: 2,  Owner: Railroad,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 74.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2019,  Bridge Improvement Cost: $15,000,  Roadway Improvement Cost: $44,000,  Total Project Cost: $201,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5059,  Location: LINDBERGH VIADUCT (Lat: 40.331347,  Lng: -75.898969),  Route carried "on" structure: Business US 422B,  Year Built: 1927,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 17.16m (56.30ft),  Average Daily Traffic: 9,810 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 13,859 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: MINERAL SPRINGS CR.,STS.,  Facility Carried by Structure: US 422 BUS(LR 146)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.443,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 25.3m (83.0ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 26.91m (88.29ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $837,000,  Roadway Improvement Cost: $2,466,000,  Total Project Cost: $11,304,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5079,  Location: PRICETOWN ROAD OVER 13TH (Lat: 40.370142,  Lng: -75.911228),  Route carried "on" structure: State highway 12,  Year Built: 1980,  Status: Open,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 24,070 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 26,679 (year 2032),  Design Load: HS 20,  Features Intersected: 13 TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.015,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 32.9m (107.9ft),  Out-to-Out Width: 34.1m (111.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 96.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.00m (13.12ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5083,  Location: NORTH OF PRICETOWN ROAD (Lat: 40.376306,  Lng: -75.899364),  Route carried "on" structure: State highway 12,  Year Built: 1978,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 11,977 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,244 (year 2032),  Design Load: HS 20,  Features Intersected: T-413(SPRING VALLEY RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.346,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.70m (21.98ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5137,  Location: CENTRE AVE (Lat: 40.343600,  Lng: -75.928700),  Route carried "on" structure: State highway 61,  Year Built: 1918,  Status: Posted for load,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 2,738 (year 2022),  Truck Traffic: 12%,  Average Future Daily Traffic: 3,402 (year 2032),  Design Load: HS 20,  Features Intersected: NORFOLK SOUTHERN RR,  Facility Carried by Structure: SR2087(LR 160)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: Railroad,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 4.3m (14.1ft),  Right: 4.3m (14.1ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Operating Rating: 21.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 12.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 2.30m (7.55ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: December 2020,  Critical Feature Inspection Date: December 2020,  Other Special Inspection Date: June 2021,  Bridge Improvement Cost: $92,000,  Roadway Improvement Cost: $270,000,  Total Project Cost: $1,239,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5221,  Location: PENN ST BRIDGE (Lat: 40.335378,  Lng: -75.936258),  Route carried "on" structure: Business US 422B,  Year Built: 1913,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 33.25m (109.09ft),  Average Daily Traffic: 19,412 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 46,833 (year 2032),  Design Load: HL 93,  Features Intersected: SCH.RIVER;STREETS;NOR/FO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.162,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 9,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 40.70m (133.53ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2020,  Underwater Inspection Date: December 2019,  Bridge Improvement Cost: $393,000,  Roadway Improvement Cost: $1,158,000,  Total Project Cost: $5,309,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5308,  Location: NW OF PA 724/I-176 INTER. (Lat: 40.302253,  Lng: -75.905700),  Route carried "on" structure: City street ,  Year Built: 1917,  Year Reconstructed: 1952,  Status: Open,  Structure Length: 16.76m (54.99ft),  Average Daily Traffic: 1,086 (year 1985),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,520 (year 2005),  Design Load: HS 20,  Features Intersected: SCHUYLKILL RIVER,  Facility Carried by Structure: POPLAR NECK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 6,  Length of Maximum Span: 27.7m (90.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 17.60m (57.74ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 5483,  Location: COURT ST.BRIDGE (Lat: 40.336206,  Lng: -75.924011),  Route carried "on" structure: ServiceCity street ,  Year Built: 1969,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 2,500 (year 1989),  Truck Traffic: 1%,  Average Future Daily Traffic: 3,500 (year 2009),  Design Load: HS 20,  Features Intersected: NORFLOK SOTHERN RR,  Facility Carried by Structure: COURT ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 8.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.70m (8.86ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $7,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $91,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5485,  Location: NEAR ALVERNIA COLLEGE (Lat: 40.314967,  Lng: -75.933444),  Route carried "on" structure: Business City street ,  Year Built: 1988,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 2,500 (year 2010),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,000 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: NORFOLK SOUTHERN RR,  Facility Carried by Structure: UPLAND AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.1m (111.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.40m (14.44ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5486,  Location: NB PA 183 IN READING (Lat: 40.343067,  Lng: -75.935458),  Route carried "on" structure: Business City street 183,  Year Built: 1986,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 5,000 (year 2010),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,000 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: NORFOLK SOUTHERN RR,  Facility Carried by Structure: FRONT STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.30m (7.55ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5487,  Location: BUTTONWOOD ST. - READING (Lat: 40.339119,  Lng: -75.943206),  Route carried "on" structure: City street ,  Year Built: 1932,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 23.47m (77.00ft),  Average Daily Traffic: 14,674 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 14,791 (year 2025),  Design Load: HS 20,  Features Intersected: SCH.R.,422,NSRC,RIV.RD.,  Facility Carried by Structure: BUTTONWOOD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: County Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 6,  Length of Maximum Span: 37.5m (123.0ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Inventory Rating: 61.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 24.00m (78.74ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: November 2019,  Bridge Improvement Cost: $258,000,  Roadway Improvement Cost: $759,000,  Total Project Cost: $3,480,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5518,  Location: CITY/BOROUGH LINE (Lat: 40.351128,  Lng: -75.956872),  Route carried "on" structure: State highway ,  Year Built: 1959,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 11.58m (37.99ft),  Average Daily Traffic: 12,772 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 16,760 (year 2032),  Design Load: HS 20,  Features Intersected: TULPEHOCKEN CREEK;STREET,  Facility Carried by Structure: RAMP SR 8042
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 12.50m (41.01ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41578,  Location: READING MUSEUM (Lat: 40.327350,  Lng: -75.949775),  Route carried "on" structure: City street ,  Year Built: 1930,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 4,000 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,000 (year 2030),  Features Intersected: WYOMISSING CREEK,  Facility Carried by Structure: MUSEUM ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Maintenance Responsibility: Town or Township Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 16.0m (52.5ft)

Condition: Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: 4194,  Location: ANGELICA PARK (Lat: 40.310950,  Lng: -75.924078),  Route carried "on" structure: State highway 10,  Year Built: 2003,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 3,301 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 7,869 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: ANGELICA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.335,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 3.20m (10.50ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 53607,  Location: Angelica Park (Lat: 40.309406,  Lng: -75.930875),  Route carried "on" structure: City street ,  Year Built: 2017,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 500 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 610 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Angelica Creek,  Facility Carried by Structure: St Bernadine St
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 4735,  Location: EXIT 10(3) PA. 724 (Lat: 40.298672,  Lng: -75.900917),  Route carried "under" structure: State highway 724,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 9,036 (year 2020),  Truck Traffic: 11%,  Features Intersected: PA 724(LR 147),  Facility Carried by Structure: I-176 (LR 1011) NB
Minimum Vertical Clearance: 4.79m (15.72ft),  Kilometerpoint: 11.079,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>   Show street view

Structure Number: 4737,  Location: EXIT 10(3) PA. 724 (Lat: 40.298844,  Lng: -75.901186),  Route carried "under" structure: State highway 724,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 9,036 (year 2020),  Truck Traffic: 11%,  Features Intersected: PA 724(LR 147),  Facility Carried by Structure: I-176 (LR 1011) SB
Minimum Vertical Clearance: 4.30m (14.11ft),  Kilometerpoint: 11.079,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>   Show street view

Structure Number: 4742,  Location: SCHUYLKILL AVE (Lat: 40.349889,  Lng: -75.943417),  Route carried "under" structure: City street ,  Year Built: 1924,  Structure Length: 0. m,  Average Daily Traffic: 700 (year 1994),  Truck Traffic: 1%,  Features Intersected: SCHUYLKILL RIV;NSRC;ROAD,  Facility Carried by Structure: PA 183(LR 310)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Length of Maximum Span: 32.3m (106.0ft)

Find on map >>   Show street view

Structure Number: 4744,  Location: SCHUYLKILL AVE. (Lat: 40.355978,  Lng: -75.948781),  Route carried "under" structure: State highway 12,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 29,969 (year 2022),  Truck Traffic: 4%,  Features Intersected: PA 12(LR 784& LR 06150),  Facility Carried by Structure: PA 183 (SR 310)
Minimum Vertical Clearance: 4.24m (13.91ft),  Kilometerpoint: 0.991,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 4744,  Location: SCHUYLKILL AVE. (Lat: 40.355978,  Lng: -75.948781),  Route carried "under" structure: State highway 12,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 30,995 (year 2022),  Truck Traffic: 4%,  Features Intersected: PA 12(LR 784& LR 06150),  Facility Carried by Structure: PA 183 (SR 310)
Minimum Vertical Clearance: 4.45m (14.60ft),  Kilometerpoint: 0.990,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Discuss Reading, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.