Inspection findings

Inspection Type

Date

Score

  • Water Quality Recording
    TSSP&S 265.204 (Eff Oct 1, 1999) - Water Quality, pages 36 - 39 and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Pool/spa operators and managers shall maintain the quality of water in all pools and spas to comply with City of Fort Worth Ordinances and the State Standard.
    Thank you for maintaining good pool water quality. Cyanuric acid - 50 PPM pH - 7.2 Chlorine - 1.5
    Corrective action: Good job.
  • Electrical Requirements
    TSSP&S 265.192 (Eff Oct 1, 1999) - Electrical Requirements, pages 43 - 45; TDSPSPC 337.93 (Eff Jun 13, 1965)and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). All electrical components shall be designed, constructed, installed, maintained and operated to comply with all applicable provisions of the City of Fort Worth Ordinances and the State Standard.
    Pump is not externally grounded.
    Corrective action: Pump must be externally grounded.
  • Pool Yard Enclosures
    TSSP&S 265.200 (Eff Oct 1, 1999) - Pool Yard Enclosures, pages 60 - 62 and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Pool yard enclosures shall be designed, constructed, installed and maintained to comply with all applicable provisions of City of Fort Worth Ordinances and the State Standard.
    Adequate enclosure is not provided. Southeast portion of fence can be followed to a smaller portion of fence and then scaled.
    Corrective action: The enclosure for all pools and spas (other than new Class A & B pools) which may include a fence, portion of a building, wall or other durable enclosure not associated with private premises shall have a minimum effective perpendicular height of four (4) feet measured from the deck surface on the outside of the fence, shall not be readily climbable with horizontal members less than 45 inches between their tops or have vertical members more than four (4) inches apart or a space below the fence greater than 4" inches. If the horizontal members are less than 45 inches apart, the vertical members shall be spaced no more than 1 " apart. Class C pools with chain link shall have until January 7, 2007 to comply with the city ordinance. Planters or other climbable structures shall not be within 36 inches of the outside fence.
  • Water Quality Violation
    TSSP&S 265.204 (Eff Oct 1, 1999) - Water Quality, pages 66 - 67 and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Pool/spa operators and managers shall maintain the quality of water in all pools and spas to comply with City of Fort Worth Ordinances and the State Standard.
    Operational records of tests results are not maintained.
    Corrective action: When tests are required, operational records of tests results shall be maintained for two years and shall be made available to the Director or his/her representative upon request.
  • Pool and Spa Water Supply
    TSSP&S 265.194 (Eff Oct 1, 1999) - Pool and Spa Water Supply, page 47; TDSPSPC 337.76 (Eff Jun 13, 1965) and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). The pool and spa water supply shall comply with TCEQ requirements, City of Fort Worth Ordinances and the State Standard.
    No back flow preventer on hose bib.
    Corrective action: Provide back flow preventer on hose bib.
Shared Inspection06/09/2010100
  • Handholds Specific Safety Features
    TSSP&S 265.199 (Eff Oct 1, 1999) - Specific Safety Features, pages 52 - 60; TDSPSPC 337.80,TDSPSPC 337.93,TDSPSPC 337.96 (Eff Jun 13, 1965) and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Safety features and equipment shall be designed, constructed, installed and maintained to comply with all applicable provisions of City of Fort Worth Ordinances and the State Standard.
    The ring buoy is damaged, broken or is not properly attached or maintained.
    Corrective action: The ring buoy shall be repaired or properly attached and maintained. At each Class C pool, one light, strong, non-telescoping, non-conducting 12 foot long or longer pole with attached body hook or shepherd's crook and one throwing rope that reaches at least 2/3 the maximum pool width with firmly attached 15 - 24 inch Coast Guard approved ring buoy shall be mounted in a conspicuous place within 20 feet of the pool. Both shall be provided for each 2,000 square feet of water surface and shall be accessible.
  • Pool Yard Enclosures
    TSSP&S 265.200 (Eff Oct 1, 1999) - Pool Yard Enclosures, pages 60 - 62 and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Pool yard enclosures shall be designed, constructed, installed and maintained to comply with all applicable provisions of City of Fort Worth Ordinances and the State Standard.
    Adequate enclosure is not provided. The gate closers constitute climable structures. Adequate gates/doors are not provided. The gates are not self-latching.
    Corrective action: The enclosure for new Class A & B pools which may include a fence, portion of a building, wall or other durable enclosure not associated with private premises shall have a minimum effective perpendicular height of six (6) feet measured from the outside of the fence, shall not be readily climbable or have vertical members more than four (4) inches apart and all openings in the barriers shall be equipped with gates or doors which are directly supervised or locked to prevent unauthorized entry. All gates or doors for pools and spas (other than new Class A & B pools) shall be lockable and equipped with self-locking and self-latching devices. An inaccessible opener mounted on the enclosure shall be installed at least 3.5 feet above the deck/walkway surface, shall open outward away from the pool/spa and shall be latched when the pool or spa is not in use or when nearby or associated pools/spas are closed as a result of a hazard or other unsafe condition. All ingress and egress to access a pool or spa shall be through common pool enclosure gates or doors.
  • COMMENT:
    The fence and gate violations shall be completed within 7 days.
Regular Inspection07/16/2009100

Do you have any questions you'd like to ask about WARWICK APARTMENTS? Post them here so others can see them and respond.

×
WARWICK APARTMENTS respresentatives - respond and add information

Write your review!

Your Ratings

You can rate this restaurant in different categories from 1 star (worst) to 5 stars (best) or leave category unrated

Food:
Service:
Price:
Ambience:
Cleanliness:

Your Review


Would you recommend WARWICK APARTMENTS to others? (optional)
  
Add photo of WARWICK APARTMENTS (optional)
Add more info about the restaurant »

About You

Your nickname:

Optional Verification

(additional info to increase the weight and the placement of your review and ratings)

Real Name:
Email (won't be published):
Date and time of your visit to this restaurant:
Phone number (won't be published):
Leave your signature»

Recently added reviews

Name City Users' Rating
LUCKY 7 FOOD STOREFort Worth, TX
*****
DOS MOLINASFort Worth, TX
DOMINOS PIZZA #6982Fort Worth, TX
*•
WENDYS #0952Fort Worth, TX
*****
STARBUCKS STORE #2874Fort Worth, TX
*
SUBWAY #31666Fort Worth, TX
*****
GATEWAY PARK CONCESSIONSFort Worth, TX
***
FAMILY DOLLAR #11009Fort Worth, TX
COSTCO WHOLESALE #489Fort Worth, TX
***•
DOMINOS PIZZA #6874Fort Worth, TX
*

Restaurants in neighborhood

Name

36P
16F
VEGAS FOOD STORE

Create your own business profile on city-data.com. It's completely free!
Business Search - 14 Million verified businesses
Search for:  near: