Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Cary, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 151Number of bridges
  • 1,434ft / 437mTotal length
  • 4,169,587Total average daily traffic
  • 604,387Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Cary
  • No street view available for this location

New bridges in Cary, NC - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 21950-1959
  • 91960-1969
  • 91970-1979
  • 271980-1989
  • 531990-1999
  • 142000-2009
  • 322010-2019
  • 32020-2022
Reconstructed bridges in Cary, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 11980-1989
Average Bridge Truck Traffic in Cary, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 1.7%Excellent
  • 1.7%Very good
  • 57.6%Good
  • 25.4%Satisfactory
  • 13.6%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 1.7%Excellent
  • 16.9%Very good
  • 47.5%Good
  • 22.0%Satisfactory
  • 11.9%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 18.6%Very good
  • 54.2%Good
  • 18.6%Satisfactory
  • 6.8%Fair
  • 1.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 1.6%Very good
  • 50.0%Good
  • 30.6%Satisfactory
  • 16.1%Fair
  • 1.6%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 35.3%Good
  • 41.2%Satisfactory
  • 23.5%Fair
Find on map >>   Show street view

Structure Number: 1830652,  Location: 0.1 MI. N. JCT. SR1009 (Lat: 35.745292,  Lng: -78.763914),  Route carried "on" structure: State highway 3977,  Year Built: 1990,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 24,500 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 49,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LYNN BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2020,  Underwater Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1830663,  Location: 0.1 MI.N. JCT. SR1009 (Lat: 35.737194,  Lng: -78.792878),  Route carried "on" structure: US 1,  Year Built: 1993,  Status: Open,  Structure Length: 9.87m (32.38ft),  Average Daily Traffic: 55,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 110,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.870,  Lanes on structure: 2,  Lanes under structure: 9,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 13 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 49.3m (161.7ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1830664,  Location: 0.12 MI. W. JCT. SR1300 (Lat: 35.737114,  Lng: -78.789014),  Route carried "on" structure: State highway 1009,  Year Built: 1993,  Status: Open,  Structure Length: 4.84m (15.88ft),  Average Daily Traffic: 14,000 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 28,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US64E. RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.2m (154.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 65.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1830673,  Location: 0.2 MI. S. NC54 (Lat: 35.796628,  Lng: -78.799281),  Route carried "on" structure: State highway 3073,  Year Built: 1993,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 21,000 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 42,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DURHAM&SOUTHERN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.8m (97.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 18.2m (59.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1830674,  Location: 200'W.JCT.MADISON AVE. (Lat: 35.794247,  Lng: -78.798803),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 300 (year 1994),  Truck Traffic: 7%,  Average Future Daily Traffic: 600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: COLES BRANCH,  Facility Carried by Structure: CARROUSEL LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1830675,  Location: .2MI.E.JCT.NORWELL BLVD. (Lat: 35.820347,  Lng: -78.785314),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 7.98m (26.18ft),  Average Daily Traffic: 11,000 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 22,000 (year 2040),  Design Load: HS 20,  Features Intersected: BLACK CREEK,  Facility Carried by Structure: CARY PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1830676,  Location: .1MI.W.JCT.HIGH HOUSE RD. (Lat: 35.798306,  Lng: -78.817925),  Route carried "on" structure: State highway 3977,  Year Built: 1992,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 24,000 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 48,000 (year 2040),  Features Intersected: COLES BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 26.3m (86.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2022,  Underwater Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 1830677,  Location: .7 MI.W.OF SR1300 (Lat: 35.756072,  Lng: -78.795111),  Route carried "on" structure: State highway 3977,  Year Built: 1988,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 25,000 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 50,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SWIFT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 22 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2022,  Underwater Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 1830678,  Location: .02MI.N.JCT.OLD RALEIGH R (Lat: 35.739242,  Lng: -78.809892),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 500 (year 1994),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: WILLIAMS CREEK,  Facility Carried by Structure: MACKENAN DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1830679,  Location: 225' S.JCT.DUNCAN HILL CT (Lat: 35.749900,  Lng: -78.761819),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 500 (year 1994),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STRAIGHT BRANCH,  Facility Carried by Structure: FOREST PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1830682,  Location: 0.1 MI.W.JCT.GREGORY DR. (Lat: 35.800181,  Lng: -78.776514),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 600 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,200 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLACK CREEK,  Facility Carried by Structure: BELHAVEN DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1830684,  Location: 0.44MI.E. OF JCT.SR1613 (Lat: 35.793019,  Lng: -78.839600),  Route carried "on" structure: State highway 1615,  Year Built: 1994,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 28,000 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 56,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: TRIB.TURKEY CR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2020,  Underwater Inspection Date: November 2018
Find on map >>   Show street view

Structure Number: 1830723,  Location: .4 MI.W.JCT.HARRISON AVE. (Lat: 35.811719,  Lng: -78.787558),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 1,000 (year 2000),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLACK CREEK TRIBUTARY,  Facility Carried by Structure: W.DYNASTY DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1830737,  Location: 0.25MI.W.JCT.EVANS RD (Lat: 35.822939,  Lng: -78.807014),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 2,000 (year 1998),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,000 (year 2040),  Design Load: HS 20,  Features Intersected: CRABTREE CREEK TRIBUTARY,  Facility Carried by Structure: WESTON PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.8m (61.7ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1830756,  Location: 1.3 MI.N.JCT.SR1792 (Lat: 35.887333,  Lng: -78.818411),  Route carried "on" structure: State highway 1789,  Year Built: 1998,  Status: Open,  Structure Length: 11.52m (37.80ft),  Average Daily Traffic: 7,800 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 15,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I540
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 47.2m (154.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1830757,  Location: 0.3.MI. N. OF I540 S (Lat: 35.890136,  Lng: -78.815928),  Route carried "on" structure: Ramp State highway 3097,  Year Built: 1998,  Status: Open,  Structure Length: 14.90m (48.88ft),  Average Daily Traffic: 7,250 (year 2013),  Truck Traffic: 16%,  Average Future Daily Traffic: 14,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I540 & RAMP B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 49.0m (160.8ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1830758,  Location: 0.7 MI.S.SR1644 (Lat: 35.891897,  Lng: -78.813617),  Route carried "on" structure: State highway 3097,  Year Built: 1998,  Status: Open,  Structure Length: 12.22m (40.09ft),  Average Daily Traffic: 17,000 (year 2017),  Truck Traffic: 14%,  Average Future Daily Traffic: 34,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I540
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 9,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.3m (56.8ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 53.3m (174.9ft),  Curb-To-Curb Width: 17.6m (57.7ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1830942,  Location: 0.3 E. OF JCT. SR 1789 (Lat: 35.882950,  Lng: -78.810058),  Route carried "on" structure: State highway 1642,  Year Built: 1999,  Status: Open,  Structure Length: 6.79m (22.28ft),  Average Daily Traffic: 7,200 (year 1999),  Truck Traffic: 7%,  Average Future Daily Traffic: 14,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR3097
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1831011,  Location: 0.1MI. E. SR1645 (Lat: 35.902453,  Lng: -78.789833),  Route carried "on" structure: State highway 3109,  Year Built: 1994,  Status: Open,  Structure Length: 1.64m (5.38ft),  Average Daily Traffic: 21,500 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 43,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: LITTLE BRIER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 22.5m (73.8ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2020,  Underwater Inspection Date: October 2018
Find on map >>   Show street view

Structure Number: 1831017,  Location: @ JCT.NC55 (Lat: 35.840836,  Lng: -78.886556),  Route carried "on" structure: ServiceState highway 540,  Year Built: 2007,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 22,250 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 44,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC55
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.126,  Lanes on structure: 4,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 9,  Subroute: 23),  Owner: State Highway Agency,  Approaching Roadway Width: 18.8m (61.7ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831018,  Location: @ JCT.NC55 (Lat: 35.840622,  Lng: -78.886375),  Route carried "on" structure: ServiceState highway 540,  Year Built: 2007,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 22,250 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 44,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC55
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.126,  Lanes on structure: 4,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 9,  Subroute: 23),  Owner: State Highway Agency,  Approaching Roadway Width: 18.5m (60.7ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831055,  Location: 1.4 MI. W. JCT. SR1630 (Lat: 35.853447,  Lng: -78.894603),  Route carried "on" structure: State highway 55,  Year Built: 1970,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 4,400 (year 2015),  Truck Traffic: 12%,  Average Future Daily Traffic: 8,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: KIT CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 1831065,  Location: 200FT.W.JCT.GREGORY DR. (Lat: 35.796964,  Lng: -78.774983),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 250 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLACK CREEK,  Facility Carried by Structure: KINGSWOOD DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1831104,  Location: 0.3 MI.S.JCT.GREENLEVEL R (Lat: 35.816728,  Lng: -78.905739),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 100 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: PANTHER CREEK,  Facility Carried by Structure: CARY GLEN BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2022,  Underwater Inspection Date: Febuary 2022
Find on map >>   Show street view

Structure Number: 1831212,  Location: .15MI.W.LOUIS STEPHENS DR (Lat: 35.808875,  Lng: -78.864422),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 250 (year 2008),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,000 (year 2040),  Design Load: HS 20,  Features Intersected: HATCHET GROVE TRIBUTARY,  Facility Carried by Structure: HERITAGE PINES DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 86.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1831296,  Location: 0.5 MI.N. OF JCT.SR 1608 (Lat: 35.772678,  Lng: -78.885800),  Route carried "on" structure: State highway 540,  Year Built: 2012,  Status: Open,  Structure Length: 8.10m (26.57ft),  Average Daily Traffic: 11,500 (year 2015),  Truck Traffic: 12%,  Average Future Daily Traffic: 23,000 (year 2040),  Design Load: HL 93,  Features Intersected: JACKS BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.714,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 40),  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831297,  Location: 0.5 MI.N.JCT.SR1608 (Lat: 35.772550,  Lng: -78.885417),  Route carried "on" structure: State highway 540,  Year Built: 2012,  Status: Open,  Structure Length: 8.10m (26.57ft),  Average Daily Traffic: 6,500 (year 2013),  Truck Traffic: 12%,  Average Future Daily Traffic: 13,000 (year 2040),  Design Load: HL 93,  Features Intersected: JACKS BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 40),  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831298,  Location: 0.4 MI.S.JCT.SR1615 (Lat: 35.777586,  Lng: -78.885753),  Route carried "on" structure: State highway 540,  Year Built: 2012,  Status: Open,  Structure Length: 21.12m (69.29ft),  Average Daily Traffic: 11,500 (year 2015),  Truck Traffic: 12%,  Average Future Daily Traffic: 23,000 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: WHITE OAK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.775,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 9,  Subroute: 23),  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 49.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1831299,  Location: 0.4 MI.S. OF JCT.SR1615 (Lat: 35.777778,  Lng: -78.885358),  Route carried "on" structure: State highway 540,  Year Built: 2012,  Status: Open,  Structure Length: 19.53m (64.07ft),  Average Daily Traffic: 16,750 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 33,500 (year 2040),  Design Load: H 10,  Features Intersected: WHITE OAK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.775,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 3,  Subroute: 40),  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 18313,  Location: @ JCT.NC540 (Lat: 35.782817,  Lng: -78.887361),  Route carried "on" structure: State highway 1615,  Year Built: 2011,  Status: Open,  Structure Length: 6.43m (21.10ft),  Average Daily Traffic: 10,500 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 21,000 (year 2040),  Design Load: HL 93,  Features Intersected: NC540 TOLL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 18.5m (60.7ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 31.0m (101.7ft),  Curb-To-Curb Width: 22.5m (73.8ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 64.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831301,  Location: 0.5 MI.E.JCT.SR1600 (Lat: 35.803281,  Lng: -78.891225),  Route carried "on" structure: State highway 1621,  Year Built: 2011,  Status: Open,  Structure Length: 8.22m (26.97ft),  Average Daily Traffic: 200 (year 2011),  Truck Traffic: 7%,  Average Future Daily Traffic: 400 (year 2040),  Design Load: HL 93,  Features Intersected: NC540
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.2m (131.9ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 87.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831302,  Location: 4.5 MI.N.JCT US64 (Lat: 35.809156,  Lng: -78.892097),  Route carried "on" structure: State highway 3060,  Year Built: 2012,  Status: Open,  Structure Length: 6.18m (20.28ft),  Average Daily Traffic: 7,900 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 15,800 (year 2040),  Design Load: HL 93,  Features Intersected: I540
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.476,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.8m (97.8ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 58.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831303,  Location: 0.4 MI N. MORRISVILLE PKW (Lat: 35.815161,  Lng: -78.892472),  Route carried "on" structure: State highway 540,  Year Built: 2012,  Status: Open,  Structure Length: 6.82m (22.38ft),  Average Daily Traffic: 18,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 36,000 (year 2040),  Design Load: HL 93,  Features Intersected: PANTHER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.629,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 9,  Subroute: 23),  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831304,  Location: .4 MI N. MORRISVILLE PKWY (Lat: 35.815047,  Lng: -78.892086),  Route carried "on" structure: State highway 540,  Year Built: 2012,  Status: Open,  Structure Length: 6.82m (22.38ft),  Average Daily Traffic: 18,000 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 36,000 (year 2040),  Design Load: HL 93,  Features Intersected: PANTHER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.629,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 9,  Subroute: 23),  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831305,  Location: .6 MI. W. OF JCT. SR1625 (Lat: 35.822675,  Lng: -78.892989),  Route carried "on" structure: State highway 1624,  Year Built: 2012,  Status: Open,  Structure Length: 6.30m (20.67ft),  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 26,000 (year 2040),  Design Load: HL 93,  Features Intersected: NC540
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.4m (99.7ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1831306,  Location: 0.6 MI.E. OF JCT.SR1625 (Lat: 35.822803,  Lng: -78.893025),  Route carried "on" structure: State highway 1624,  Year Built: 2011,  Status: Open,  Structure Length: 6.30m (20.67ft),  Average Daily Traffic: 13,000 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 26,000 (year 2040),  Design Load: HL 93,  Features Intersected: NC540
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.4m (99.7ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831307,  Location: 0.9 MI.W. OF JCT.NC55 (Lat: 35.828828,  Lng: -78.893103),  Route carried "on" structure: City street ,  Year Built: 2011,  Status: Open,  Structure Length: 6.21m (20.37ft),  Average Daily Traffic: 1,300 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,600 (year 2040),  Design Load: HL 93,  Features Intersected: NC540 TOLL,  Facility Carried by Structure: SR3127 MCCRIM.PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.1m (98.8ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831308,  Location: 0.9 MI.W. OF JCT.NC55 (Lat: 35.828700,  Lng: -78.893139),  Route carried "on" structure: City street ,  Year Built: 2011,  Status: Open,  Structure Length: 6.21m (20.37ft),  Average Daily Traffic: 7,500 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 15,000 (year 2040),  Design Load: HL 93,  Features Intersected: NC540,  Facility Carried by Structure: SR3127
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.1m (98.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 63.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831309,  Location: 0.5 MI.N. OF SR3127 (Lat: 35.836025,  Lng: -78.890497),  Route carried "on" structure: Bypass State highway 540,  Year Built: 2012,  Status: Open,  Structure Length: 8.16m (26.77ft),  Average Daily Traffic: 22,250 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 44,500 (year 2040),  Design Load: HL 93,  Features Intersected: NANCY BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.056,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 9,  Subroute: 23),  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.3m (102.7ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1831317,  Location: .2MI.S.JCT.MORRISVILLE PW (Lat: 35.810936,  Lng: -78.863681),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 1.03m (3.38ft),  Average Daily Traffic: 7,700 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 15,400 (year 2040),  Design Load: HS 20,  Features Intersected: HATCHET GROVE TRIBUTARY,  Facility Carried by Structure: LOUIS STEVENS DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.2m (13.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 73.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 183132,  Location: 0.9MI.WEST JCT.NC55 (Lat: 35.728075,  Lng: -78.865667),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 4,700 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,400 (year 2040),  Design Load: HS 20,  Features Intersected: CREEK,  Facility Carried by Structure: APEX PEAKWAY
Minimum Vertical Clearance: 0.00m,  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 1831325,  Location: 0.1 MI W. JCT. SR3015 (Lat: 35.864517,  Lng: -78.806064),  Route carried "on" structure: Ramp State highway 3015,  Year Built: 1997,  Status: Open,  Structure Length: 4.41m (14.47ft),  Average Daily Traffic: 9,000 (year 2015),  Truck Traffic: 12%,  Average Future Daily Traffic: 18,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR3015,  Facility Carried by Structure: SR1002 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Segmental Box Girder,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.6m (139.8ft),  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 71.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Cary, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.