Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Colorado Springs, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 385Number of bridges
  • 4,846ft / 1,477mTotal length
  • $47,397,000Total costs
  • 8,288,363Total average daily traffic
  • 508,845Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Colorado Springs
  • No street view available for this location

New bridges in Colorado Springs, CO - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 11900-1909
  • 31910-1919
  • 81930-1939
  • 41940-1949
  • 281950-1959
  • 381960-1969
  • 461970-1979
  • 681980-1989
  • 631990-1999
  • 752000-2009
  • 432010-2019
  • 72020-2022
Reconstructed bridges in Colorado Springs, CO - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 61960-1969
  • 11970-1979
  • 11980-1989
  • 01990-1999
  • 62000-2009
  • 12010-2019
Average Bridge Daily Traffic in Colorado Springs, CO
Average Bridge Truck Traffic in Colorado Springs, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.5%Very good
  • 42.2%Good
  • 35.1%Satisfactory
  • 9.5%Fair
  • 3.3%Poor
  • 0.5%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 21.8%Very good
  • 43.6%Good
  • 23.7%Satisfactory
  • 10.0%Fair
  • 0.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 12.3%Very good
  • 48.8%Good
  • 28.4%Satisfactory
  • 8.5%Fair
  • 1.9%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 34.2%Very good
  • 36.0%Good
  • 23.3%Satisfactory
  • 5.8%Fair
  • 0.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 3.5%Very good
  • 18.1%Good
  • 58.3%Satisfactory
  • 16.7%Fair
  • 3.5%Poor
Find on map >>   Show street view

Structure Number: CSG-F.80-06.50A,  Location: 0.1 MI S OF CHEYENNE RD (Lat: 38.802778,  Lng: -104.834444),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 8,300 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,873 (year 2041),  Design Load: HS 20,  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: ALSACE WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.490,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-F.84-12.00A,  Location: 0.6 MI N OF FILLMORE (Lat: 38.883172,  Lng: -104.834333),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 2,475 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,243 (year 2041),  Design Load: HS 20,  Features Intersected: S.DOUGLAS CREEK,  Facility Carried by Structure: SINTON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.619,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 18.5m (60.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 38.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-F.85-08.23A,  Location: 0.1 MI E OF I-25 (Lat: 38.827461,  Lng: -104.834433),  Route carried "on" structure: City street ,  Year Built: 2017,  Status: Open,  Structure Length: 7.92m (25.98ft),  Average Daily Traffic: 16,597 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 21,742 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: FOUNTAIN CREEK,  Facility Carried by Structure: CIMARRON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 255.858,  Lanes on structure: 7,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 32.4m (106.3ft),  Out-to-Out Width: 33.4m (109.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.78m (32.09ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-F.90-15.6,  Location: .5 MI N ROCKRIMMON (Lat: 38.933497,  Lng: -104.833431),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 1.60m (5.25ft),  Average Daily Traffic: 484 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 634 (year 2041),  Design Load: HS 20,  Features Intersected: DRY CREEK,  Facility Carried by Structure: PEBBLE WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.064,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.5m (47.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 53.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-F.98-11.59,  Location: 0.1 MI E OF I-25 (Lat: 38.876261,  Lng: -104.832631),  Route carried "on" structure: City street ,  Year Built: 1961,  Year Reconstructed: 1971,  Status: Open,  Structure Length: 3.76m (12.34ft),  Average Daily Traffic: 34,925 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 45,752 (year 2041),  Design Load: HS 20,  Features Intersected: UP RR,  Facility Carried by Structure: FILLMORE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.675,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.3m (43.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-F.99-08.57A,  Location: JUST E OF I-25 (Lat: 38.832608,  Lng: -104.832661),  Route carried "on" structure: City street ,  Year Built: 1998,  Status: Open,  Structure Length: 10.08m (33.07ft),  Average Daily Traffic: 13,612 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 17,831 (year 2041),  Design Load: HS 20,  Features Intersected: MONUMENT CREEK,  Facility Carried by Structure: COLORADO AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.122,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 23 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.1m (111.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 20.0m (65.6ft),  Out-to-Out Width: 29.1m (95.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-F.99-11.31A,  Location: 2 BLKS W OF TREMONT ST (Lat: 38.872406,  Lng: -104.831186),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 948 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,241 (year 2041),  Design Load: HS 20,  Features Intersected: MONUMENT CREEK,  Facility Carried by Structure: POLK STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.063,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.5m (106.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 77.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: CSG-G.00-08.57A,  Location: 0.2 MI E OF I25 (Lat: 38.832578,  Lng: -104.831075),  Route carried "on" structure: City street ,  Year Built: 1998,  Status: Open,  Structure Length: 19.10m (62.66ft),  Average Daily Traffic: 13,843 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 18,134 (year 2041),  Design Load: HS 20,  Features Intersected: RAILROAD/SIERRA MADRE ST,  Facility Carried by Structure: COLORADO AVENUE
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 4.252,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 36.8m (120.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 18.6m (61.0ft),  Out-to-Out Width: 25.5m (83.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.01-05.73,  Location: JUST S OF LAKE AVENUE (Lat: 38.791850,  Lng: -104.834433),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 3,225 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,225 (year 2041),  Features Intersected: RESERVOIR CANAL,  Facility Carried by Structure: OLD BROADMOOR RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.085,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: CSG-G.03-08.18A,  Location: 0.2 MI E OF I25 (Lat: 38.827094,  Lng: -104.831233),  Route carried "on" structure: City street ,  Year Built: 2009,  Status: Open,  Structure Length: 8.76m (28.74ft),  Average Daily Traffic: 16,597 (year 2021),  Average Future Daily Traffic: 21,742 (year 2041),  Features Intersected: UP RR/CONEJOS ST,  Facility Carried by Structure: CIMARRON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.311,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 45.9m (150.6ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 30.6m (100.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.06-09.54,  Location: JUST W OF MESA ROAD (Lat: 38.846069,  Lng: -104.828903),  Route carried "on" structure: City street ,  Year Built: 1940,  Status: Open,  Structure Length: 6.66m (21.85ft),  Average Daily Traffic: 1,418 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,858 (year 2041),  Features Intersected: MONUMENT CREEK,  Facility Carried by Structure: MESA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: CSG-G.11-09.84E,  Location: .1 MI E OF I-25 (Lat: 38.850997,  Lng: -104.829169),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 6.79m (22.28ft),  Average Daily Traffic: 15,110 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,794 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: MONUMENT CREEK,  Facility Carried by Structure: EB UINTAH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.961,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.7m (28.5ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 50.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.11-09.84W,  Location: .1 MI E OF I-25 (Lat: 38.851133,  Lng: -104.829103),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 6.79m (22.28ft),  Average Daily Traffic: 17,630 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 23,096 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: MONUMENT CREEK,  Facility Carried by Structure: WB UINTAH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.965,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.7m (28.5ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 50.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.13-06.97,  Location: 0.1 MI N OF CHEYENNE BLVD (Lat: 38.809172,  Lng: -104.829031),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 433 (year 2021),  Average Future Daily Traffic: 567 (year 2041),  Design Load: HS 20,  Features Intersected: CHEYENNE RUN,  Facility Carried by Structure: WOODBURN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.310,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.9m (9.5ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 50.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: CSG-G.14-11.58,  Location: 0.15 MI E OF I25 (Lat: 38.876128,  Lng: -104.831408),  Route carried "on" structure: City street ,  Year Built: 1961,  Year Reconstructed: 1971,  Status: Open,  Structure Length: 8.79m (28.84ft),  Average Daily Traffic: 32,155 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 42,123 (year 2041),  Design Load: HS 20,  Features Intersected: MONUMENT CREEK,  Facility Carried by Structure: FILLMORE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.781,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.3m (76.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 39.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-G.15-08.84A,  Location: JUST E OF I-25 (Lat: 38.836897,  Lng: -104.829192),  Route carried "on" structure: City street ,  Year Built: 2007,  Status: Open,  Structure Length: 14.60m (47.90ft),  Average Daily Traffic: 12,153 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,920 (year 2041),  Features Intersected: MONUMENT CREEK/UPRR,  Facility Carried by Structure: BIJOU STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.054,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 24.7m (81.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 43.8m (143.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 24.7m (81.0ft),  Out-to-Out Width: 29.1m (95.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 27.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.18-12.,  Location: 0.5 MI N OF FILLMORE (Lat: 38.882494,  Lng: -104.829306),  Route carried "on" structure: City street ,  Year Built: 1984,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 2,007 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,630 (year 2041),  Design Load: HS 20,  Features Intersected: SOUTH DOUGLAS CREEK,  Facility Carried by Structure: MARK DABLING BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.771,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.8m (15.7ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 21.2m (69.6ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 50.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020
Find on map >>   Show street view

Structure Number: CSG-G.21-04.96,  Location: JUST SOUTH OF HIDDEN CREE (Lat: 38.779711,  Lng: -104.831600),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 3,060 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,009 (year 2041),  Features Intersected: HIDDEN CREEK,  Facility Carried by Structure: BROADMOOR VALLEY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.464,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: CSG-G.23-06.80A,  Location: JUST N 0F CHEYENNE ROAD (Lat: 38.806900,  Lng: -104.826844),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 6,059 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 7,938 (year 2041),  Design Load: HS 20,  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: CASCADE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.024,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: CSG-G.23-06.98,  Location: 0.2 MI W OF NEVADA AVENUE (Lat: 38.809722,  Lng: -104.824169),  Route carried "on" structure: City street ,  Year Built: 1955,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 1,659 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,173 (year 2041),  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: RAMONA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.225,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-G.31-06.96,  Location: JUST W OF CASCADE AVENUE (Lat: 38.806667,  Lng: -104.827222),  Route carried "on" structure: City street ,  Year Built: 1971,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 11,463 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 15,016 (year 2041),  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: WEST CHEYENNE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.455,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.9m (22.6ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-G.34-05.83,  Location: 0.2 MI S OF LAKE AVE (Lat: 38.793558,  Lng: -104.828136),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 1.63m (5.35ft),  Average Daily Traffic: 2,904 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,804 (year 2041),  Features Intersected: RESERVOIR SPILLWAY,  Facility Carried by Structure: SPRINGMEADOW DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.854,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.5m (47.6ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: CSG-G.36-12.48,  Location: 0.5 MI S GARDEN OF GOD RD (Lat: 38.889319,  Lng: -104.826575),  Route carried "on" structure: City street ,  Year Built: 1984,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 2,216 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,903 (year 2041),  Design Load: HS 20,  Features Intersected: DOUGLAS CREEK,  Facility Carried by Structure: MARK DABLING BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.642,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 19.1m (62.7ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 94.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 56.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020
Find on map >>   Show street view

Structure Number: CSG-G.38-07.42A,  Location: JUST N OF I25 (Lat: 38.815719,  Lng: -104.824361),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 9.83m (32.25ft),  Average Daily Traffic: 3,049 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,995 (year 2041),  Design Load: HS 20,  Features Intersected: FOUNTAIN CREEK,  Facility Carried by Structure: TEJON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.735,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.3m (106.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 25.0m (82.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.38-11.08A,  Location: 0.4 MI SOUTH OF FILLMORE (Lat: 38.869489,  Lng: -104.823286),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 7,659 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 10,033 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: RAILROAD VAN BUREN,  Facility Carried by Structure: CASCADE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.349,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.4m (86.6ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 45.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.42-06.97,  Location: .2 MI E OF CASCADE (Lat: 38.808278,  Lng: -104.825275),  Route carried "on" structure: City street ,  Year Built: 1959,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 1,695 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,220 (year 2041),  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: SAINT ELMO AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.322,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 37.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-G.42-07.11,  Location: 0.2 MI E OF TEJON ST (Lat: 38.811600,  Lng: -104.824400),  Route carried "on" structure: City street ,  Year Built: 1971,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 3,012 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,946 (year 2041),  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: NAVAJO STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.056,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.6m (28.2ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.0m,  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-G.42-07.19,  Location: 0.1 MI E OF TEJON (Lat: 38.812500,  Lng: -104.823892),  Route carried "on" structure: City street ,  Year Built: 1976,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 3,260 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,271 (year 2041),  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: BROOKSIDE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.485,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: CSG-G.47-14.09,  Location: AT INT. WITH ROCKRIMMON (Lat: 38.914444,  Lng: -104.824169),  Route carried "on" structure: City street ,  Year Built: 1977,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 5,654 (year 2021),  Average Future Daily Traffic: 7,407 (year 2041),  Features Intersected: NORTH ROCKRIMMON CHANNEL,  Facility Carried by Structure: PRO RODEO DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.953,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.8m (22.3ft),  Curb-To-Curb Width: 34.7m (113.8ft),  Out-to-Out Width: 35.1m (115.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: CSG-G.48-07.25,  Location: SW OF I-25 and NEVADA S (Lat: 38.814006,  Lng: -104.822919),  Route carried "on" structure: City street ,  Year Built: 2004,  Status: Open,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 8,874 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,625 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: CHEYENNE CREEK,  Facility Carried by Structure: MOTOR WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.689,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 23.4m (76.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 67.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.48-21.6,  Location: 0.5 MI S OF N GATE BLVD (Lat: 39.020889,  Lng: -104.823611),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 5.71m (18.73ft),  Average Daily Traffic: 783 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,026 (year 2041),  Design Load: HL 93,  Features Intersected: VOYAGER PKWY/ I-25 RAMPS,  Facility Carried by Structure: SPECTRUM LOOP ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.368,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.50-07.42,  Location: JUST N OF I-25 (Lat: 38.815608,  Lng: -104.822194),  Route carried "on" structure: City street ,  Year Built: 2003,  Status: Open,  Structure Length: 9.58m (31.43ft),  Average Daily Traffic: 28,277 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 37,043 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: FOUNTAIN CREEK,  Facility Carried by Structure: NEVADA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.019,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.8m (101.0ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 31.8m (104.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.57-13.05A,  Location: 0.1 MI W OF NEVADA (Lat: 38.897019,  Lng: -104.820453),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 44,579 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 58,398 (year 2041),  Features Intersected: MONUMENT CREEK,  Facility Carried by Structure: GARDEN OF GODS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.543,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 23.9m (78.4ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 25.3m (83.0ft),  Out-to-Out Width: 29.9m (98.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: CSG-G.59-12.45,  Location: SOUTH OF MOUNTVIEW STREET (Lat: 38.888794,  Lng: -104.818869),  Route carried "on" structure: City street ,  Year Built: 1949,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 2.00m (6.56ft),  Average Daily Traffic: 18,345 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 24,032 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: TEMPLETON GAP FLOODWAY,  Facility Carried by Structure: NEVADA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.945,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 35.4m (116.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 35.4m (116.1ft),  Out-to-Out Width: 40.8m (133.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 51.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.00m (6.56ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: CSG-G.60-11.15N,  Location: .2 MI S. OF FILLMORE ST. (Lat: 38.870622,  Lng: -104.819586),  Route carried "on" structure: City street ,  Year Built: 1949,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 8,919 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 11,684 (year 2041),  Design Load: HS 20,  Features Intersected: CS and E RR, VAN BUREN C,  Facility Carried by Structure: NEVADA AVE NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.974,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.0m (42.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.60-11.15S,  Location: .2 MI S OF FILLMORE ST (Lat: 38.870569,  Lng: -104.819822),  Route carried "on" structure: City street ,  Year Built: 1949,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 7,863 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,301 (year 2041),  Design Load: HS 20,  Features Intersected: CSE RR, VAN BUREN C,  Facility Carried by Structure: NEVADA AVE SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.981,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.0m (42.7ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.60-13.25,  Location: .6 MI N OF AUSTIN BLUFFS (Lat: 38.904397,  Lng: -104.817111),  Route carried "on" structure: City street ,  Year Built: 2009,  Status: Open,  Structure Length: 2.12m (6.96ft),  Average Daily Traffic: 36,709 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 48,088 (year 2041),  Features Intersected: PEDESTRIAN UNDERPASS,  Facility Carried by Structure: NEVADA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.217,  Lanes on structure: 7,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 31.8m (104.3ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.7m (64.6ft),  Curb or Sidewalk Widths: Left: 4.4m (14.4ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 46.0m (150.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.65-15.5,  Location: 0.4 MI W OF I-25. (Lat: 38.932283,  Lng: -104.818239),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 2.59m (8.50ft),  Average Daily Traffic: 21,121 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 27,668 (year 2041),  Design Load: HS 20,  Features Intersected: BNSF RAILROAD,  Facility Carried by Structure: WOODMEN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.566,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.0m (72.2ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.8m (78.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 27.1m (88.9ft),  Out-to-Out Width: 30.9m (101.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: CSG-G.72-08.87,  Location: JUST E OF N CORONA (Lat: 38.838047,  Lng: -104.815978),  Route carried "on" structure: City street ,  Year Built: 1902,  Status: Open,  Structure Length: 0.62m (2.03ft),  Average Daily Traffic: 18,034 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 23,624 (year 2041),  Features Intersected: SHOOKS RUN,  Facility Carried by Structure: PLATTE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.884,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 31.2m (102.4ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 31.2m (102.4ft),  Out-to-Out Width: 56.7m (186.0ft)

Condition: Channel: Very good,  Culverts: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Discuss Colorado Springs, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.