Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Goldsboro, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 181Number of bridges
  • 2,352ft / 717mTotal length
  • $75,000Total costs
  • 1,645,302Total average daily traffic
  • 181,338Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Goldsboro
  • No street view available for this location

New bridges in Goldsboro, NC - historical statistics
  • New bridges - historical statistics
  • 41920-1929
  • 11940-1949
  • 201950-1959
  • 111960-1969
  • 321970-1979
  • 11980-1989
  • 81990-1999
  • 272000-2009
  • 772010-2019
Reconstructed bridges in Goldsboro, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11930-1939
  • 11940-1949
  • 21950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 11990-1999
Average Bridge Daily Traffic in Goldsboro, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 1.1%Excellent
  • 3.3%Very good
  • 56.7%Good
  • 31.1%Satisfactory
  • 6.7%Fair
  • 1.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 1.1%Excellent
  • 31.1%Very good
  • 31.1%Good
  • 26.7%Satisfactory
  • 8.9%Fair
  • 1.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 1.1%Excellent
  • 22.2%Very good
  • 37.8%Good
  • 22.2%Satisfactory
  • 15.6%Fair
  • 1.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 9.8%Very good
  • 60.7%Good
  • 21.3%Satisfactory
  • 8.2%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 6.7%Good
  • 80.0%Satisfactory
  • 13.3%Fair
Find on map >>   Show street view

Structure Number: 1910365,  Location: 0.9 MI. E. JCT. US117 (Lat: 35.426356,  Lng: -77.963653),  Route carried "on" structure: Bypass US 70,  Year Built: 2012,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 27,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: NC111
Minimum Vertical Clearance: 30.44m (99.87ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.5m (96.8ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910366,  Location: 0.7 MI.E. JCT. NC111 (Lat: 35.423911,  Lng: -77.949314),  Route carried "on" structure: Bypass US 70,  Year Built: 2012,  Status: Open,  Structure Length: 16.85m (55.28ft),  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 27,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: STONEY CREEK
Minimum Vertical Clearance: 30.44m (99.87ft),  Kilometerpoint: 109.089,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910367,  Location: 0.7 MI.E. OF JCT.NC111 (Lat: 35.423725,  Lng: -77.949378),  Route carried "on" structure: Bypass Interstate 70,  Year Built: 2012,  Status: Open,  Structure Length: 16.85m (55.28ft),  Average Daily Traffic: 10,750 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 21,500 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: STONEY CREEK
Minimum Vertical Clearance: 30.44m (99.87ft),  Kilometerpoint: 109.089,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910368,  Location: 0.5 MI. S. JCT. SR1547 (Lat: 35.418833,  Lng: -77.934864),  Route carried "on" structure: State highway 1556,  Year Built: 2011,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 14,000 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 28,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: US70 BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 17.9m (58.7ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910371,  Location: .1 MI. WEST OF JCT SR1909 (Lat: 35.327111,  Lng: -77.951672),  Route carried "on" structure: State highway 1910,  Year Built: 1962,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 160 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 320 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BUNN'S BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 1910372,  Location: 0.1 MI. E. JCT. SR1710 (Lat: 35.333981,  Lng: -77.947808),  Route carried "on" structure: State highway 1961,  Year Built: 1962,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 3,000 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 6,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BRANCH OF NEUSE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 1910373,  Location: @ JCT. US70 & NC44 (Lat: 35.433333,  Lng: -78.066667),  Route carried "on" structure: US 70,  Year Built: 2014,  Status: Open,  Structure Length: 10.85m (35.60ft),  Average Daily Traffic: 6,000 (year 2016),  Truck Traffic: 12%,  Average Future Daily Traffic: 12,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC44
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 58.2m (190.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910374,  Location: 0.5 MI. N US70 (Lat: 35.433100,  Lng: -78.056600),  Route carried "on" structure: State highway 581,  Year Built: 2014,  Status: Open,  Structure Length: 6.27m (20.57ft),  Average Daily Traffic: 6,200 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 12,400 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: US70BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.3m (102.7ft),  Curb-To-Curb Width: 20.3m (66.6ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910375,  Location: 1 MI. W. JCT. I795 (Lat: 35.426389,  Lng: -78.017500),  Route carried "on" structure: Bypass US 70,  Year Built: 2015,  Status: Open,  Structure Length: 78.02m (255.97ft),  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 27,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: SR1326, LITTLE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 22,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910376,  Location: 1 MI.W. JCT. I795 (Lat: 35.426111,  Lng: -78.017500),  Route carried "on" structure: Bypass Interstate 70,  Year Built: 2015,  Status: Open,  Structure Length: 77.66m (254.79ft),  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 27,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: SR1326, LITTLE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 107.900,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 22,  Number Of Approach Spans: 11,  Length of Maximum Span: 35.3m (115.8ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910377,  Location: 0.4 MI. E. JCT. US70W (Lat: 35.428333,  Lng: -77.996667),  Route carried "on" structure: Bypass US 70,  Year Built: 2015,  Status: Open,  Structure Length: 15.75m (51.67ft),  Average Daily Traffic: 6,875 (year 2018),  Truck Traffic: 16%,  Average Future Daily Traffic: 13,750 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: US70E, US70W,SR1300
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 108.260,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 46.3m (151.9ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910378,  Location: 0.5 MI. N. JCT I795 (Lat: 35.427969,  Lng: -77.996778),  Route carried "on" structure: State highway 1300,  Year Built: 2013,  Status: Open,  Structure Length: 14.20m (46.59ft),  Average Daily Traffic: 4,300 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 8,300 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US70BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 54.5m (178.8ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 87.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910379,  Location: 0.3 MI.W.JCT.SR1556 (Lat: 35.418017,  Lng: -77.927022),  Route carried "on" structure: Bypass US 70,  Year Built: 2016,  Status: Open,  Structure Length: 11.09m (36.38ft),  Average Daily Traffic: 2,100 (year 2012),  Truck Traffic: 12%,  Average Future Daily Traffic: 4,200 (year 2040),  Design Load: HL 93,  Features Intersected: REEDY BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 109.455,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 191038,  Location: 0.3 MI.E.JCT.SR1556 (Lat: 35.417889,  Lng: -77.927064),  Route carried "on" structure: US 70,  Year Built: 2016,  Status: Open,  Structure Length: 11.09m (36.38ft),  Average Daily Traffic: 2,100 (year 2012),  Truck Traffic: 12%,  Average Future Daily Traffic: 4,200 (year 2040),  Design Load: HL 93,  Features Intersected: REEDY BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 109.455,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910381,  Location: 1.2 M E JCT SR 1714 (Lat: 35.363842,  Lng: -77.853358),  Route carried "on" structure: Bypass US 70,  Year Built: 2016,  Status: Open,  Structure Length: 18.28m (59.97ft),  Average Daily Traffic: 6,500 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 13,000 (year 2040),  Design Load: HL 93,  Features Intersected: WEST BEAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 111.344,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 6 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 37.4m (122.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910382,  Location: 1.2 MI. E. OF JCT. SR1714 (Lat: 35.364167,  Lng: -77.853889),  Route carried "on" structure: Bypass US 70,  Year Built: 2016,  Status: Open,  Structure Length: 18.28m (59.97ft),  Average Daily Traffic: 2,200 (year 2014),  Truck Traffic: 14%,  Average Future Daily Traffic: 4,400 (year 2040),  Design Load: HL 93,  Features Intersected: W. BEAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 111.344,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 16 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Number Of Approach Spans: 2,  Length of Maximum Span: 37.4m (122.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910385,  Location: 0.4 MI. N. JCT. SR1571 (Lat: 34.706028,  Lng: -78.535386),  Route carried "on" structure: State highway 1570,  Year Built: 2015,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 2,400 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,800 (year 2040),  Design Load: HL 93,  Features Intersected: US70 BYP.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910386,  Location: 0.2 MI. N. JCT. SR-1705 (Lat: 35.412086,  Lng: -77.897344),  Route carried "on" structure: US 13,  Year Built: 2014,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 11,000 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 22,000 (year 2040),  Design Load: HL 93,  Features Intersected: US70 BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 13),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.7m (90.9ft),  Curb-To-Curb Width: 25.3m (83.0ft),  Out-to-Out Width: 26.3m (86.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 59.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 46.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910387,  Location: 0.5 MI. N. JCT. US13 (Lat: 35.400000,  Lng: -77.883333),  Route carried "on" structure: State highway 1705,  Year Built: 2015,  Status: Open,  Structure Length: 6.58m (21.59ft),  Average Daily Traffic: 4,200 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 8,400 (year 2025),  Design Load: HL 93,  Features Intersected: US70 BYP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.6m (103.7ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910388,  Location: 0.4 MI. S, JCT. SR1705 (Lat: 35.403628,  Lng: -77.878222),  Route carried "on" structure: State highway 1708,  Year Built: 2015,  Status: Open,  Structure Length: 5.54m (18.18ft),  Average Daily Traffic: 200 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 400 (year 2040),  Design Load: HL 93,  Features Intersected: US70 BYP.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.1m (88.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 47.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1910389,  Location: 1.12M. W. JCT. SR1719 (Lat: 35.380750,  Lng: -77.863806),  Route carried "on" structure: State highway 1130,  Year Built: 2018,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 3,000 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,000 (year 2040),  Design Load: HL 93,  Features Intersected: US70 BYP,  Facility Carried by Structure: SR1714
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.6m (93.8ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: AFNCVKAG10173,  Location: SOUTHEAST ON S SLOCUMB ST (Lat: 35.329914,  Lng: -77.973586),  Route carried "on" structure: ServiceOther road ,  Year Built: 1965,  Year Reconstructed: 2001,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 50 (year 2020),  Average Future Daily Traffic: 60 (year 2040),  Design Load: HS 20,  Features Intersected: UNNAMED STREAM,  Facility Carried by Structure: RANGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: Air Force,  Approaching Roadway Width: 4.5m (14.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 3.8m (12.5ft),  Out-to-Out Width: 4.6m (15.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Poor,  Channel: Fair,  Operating Rating: 38.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Bridge Improvement Cost: $50,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $75,000 ( Estimate for 2018),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1910028,  Location: 0.05 MI. S. JCT. SR1249 (Lat: 35.389308,  Lng: -78.008625),  Route carried "under" structure: US 13,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2016),  Truck Traffic: 12%,  Features Intersected: SR2075
Minimum Vertical Clearance: 4.77m (15.65ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1910028,  Location: 0.05 MI. S. JCT. SR1249 (Lat: 35.389308,  Lng: -78.008625),  Route carried "under" structure: US 13,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 2016),  Truck Traffic: 12%,  Features Intersected: SR2075
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1910043,  Location: 0.65 MI.W.JCT.SR1711 (Lat: 35.378208,  Lng: -77.936778),  Route carried "under" structure: US 13,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2018),  Truck Traffic: 6%,  Features Intersected: US70E, NC111
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 1910043,  Location: 0.65 MI.W.JCT.SR1711 (Lat: 35.378208,  Lng: -77.936778),  Route carried "under" structure: US 13,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2018),  Truck Traffic: 6%,  Features Intersected: US70E, NC111
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 1910047,  Location: 0.7MI. N. JCT. US70BUS. (Lat: 35.399400,  Lng: -77.991661),  Route carried "under" structure: Bypass US 13,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 18,000 (year 2014),  Truck Traffic: 12%,  Features Intersected: US117BYP.
Minimum Vertical Clearance: 5.68m (18.64ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Find on map >>   Show street view

Structure Number: 1910047,  Location: 0.7MI. N. JCT. US70BUS. (Lat: 35.399400,  Lng: -77.991661),  Route carried "under" structure: Bypass US 13,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 18,000 (year 2014),  Truck Traffic: 12%,  Features Intersected: US117BYP.
Minimum Vertical Clearance: 5.48m (17.98ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Find on map >>   Show street view

Structure Number: 1910048,  Location: 0.65 MI.W.JCT.SR1711 (Lat: 35.378306,  Lng: -77.936592),  Route carried "under" structure: US 13,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: US70BYP WB
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 1910048,  Location: 0.65 MI.W.JCT.SR1711 (Lat: 35.378306,  Lng: -77.936592),  Route carried "under" structure: US 13,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 15,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: US70BYP WB
Minimum Vertical Clearance: 4.77m (15.65ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 1910068,  Location: 0.22 MI. S. JCT. SR1302 (Lat: 35.396814,  Lng: -78.001747),  Route carried "under" structure: US 70,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2016),  Truck Traffic: 12%,  Features Intersected: US13 N, US70 E
Minimum Vertical Clearance: 4.77m (15.65ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.4m (53.8ft)

Find on map >>   Show street view

Structure Number: 1910068,  Location: 0.22 MI. S. JCT. SR1302 (Lat: 35.396814,  Lng: -78.001747),  Route carried "under" structure: Business US 70,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2016),  Truck Traffic: 12%,  Features Intersected: US13 N, US70 E
Minimum Vertical Clearance: 4.59m (15.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.4m (53.8ft)

Find on map >>   Show street view

Structure Number: 1910069,  Location: 0.22 MI.S. JCT SR1302 (Lat: 35.396908,  Lng: -78.001947),  Route carried "under" structure: Business US 70,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2016),  Truck Traffic: 12%,  Features Intersected: US13,US70,US117
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.4m (53.8ft)

Find on map >>   Show street view

Structure Number: 1910069,  Location: 0.22 MI.S. JCT SR1302 (Lat: 35.396908,  Lng: -78.001947),  Route carried "under" structure: Business US 70,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2016),  Truck Traffic: 12%,  Features Intersected: US13,US70,US117
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.4m (53.8ft)

Find on map >>   Show street view

Structure Number: 1910078,  Location: 0.5 MI. N. JCT. US70 BUS. (Lat: 35.398944,  Lng: -77.994403),  Route carried "under" structure: State highway 1304,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 4,000 (year 2016),  Truck Traffic: 7%,  Features Intersected: US13,US70BYP,US117
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 1910079,  Location: 0.35 MI N JCT US 117 BYP (Lat: 35.400672,  Lng: -77.985811),  Route carried "under" structure: Business US 117,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 14,000 (year 2018),  Truck Traffic: 6%,  Features Intersected: US13NBL/US70EB
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.5m (60.7ft)

Find on map >>   Show street view

Structure Number: 1910081,  Location: 0.35 MI. N. JCT.US117 BYP (Lat: 35.400867,  Lng: -77.985697),  Route carried "under" structure: Business US 117,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 13,000 (year 2016),  Truck Traffic: 6%,  Features Intersected: US13S,US70W
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.3m (102.7ft)

Find on map >>   Show street view

Structure Number: 1910084,  Location: 0.11 MI.N. JCT. SR1555 (Lat: 35.396286,  Lng: -77.968419),  Route carried "under" structure: US 13,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 22,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1556
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1910084,  Location: 0.11 MI.N. JCT. SR1555 (Lat: 35.396286,  Lng: -77.968419),  Route carried "under" structure: US 13,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 22,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1556
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1910089,  Location: 0.26 MI.S.JCT.US70/US13N (Lat: 35.381481,  Lng: -77.938272),  Route carried "under" structure: State highway 1560,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 9,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: US13/US70B
Minimum Vertical Clearance: 6.45m (21.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.6m (93.8ft)

Find on map >>   Show street view

Structure Number: 191009,  Location: 185' N. OF JCT. SR1631 (Lat: 35.381611,  Lng: -77.938619),  Route carried "under" structure: State highway 1560,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 8,600 (year 2018),  Truck Traffic: 7%,  Features Intersected: US13,US70B,NC111
Minimum Vertical Clearance: 6.19m (20.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.6m (93.8ft)

Find on map >>   Show street view

Structure Number: 1910311,  Location: 0.3 MI.N.SR1560 (Lat: 35.388519,  Lng: -77.946631),  Route carried "under" structure: US 13,  Year Built: 1995,  Structure Length: 0. m,  Average Daily Traffic: 20,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1565
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 1910311,  Location: 0.3 MI.N.SR1560 (Lat: 35.388519,  Lng: -77.946631),  Route carried "under" structure: US 13,  Year Built: 1995,  Structure Length: 0. m,  Average Daily Traffic: 20,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: SR1565
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 1910332,  Location: 0.63 MI. N. JCT. US70BUS (Lat: 35.398814,  Lng: -78.008300),  Route carried "under" structure: US 70,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: I795S
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 1079.279,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 1910332,  Location: 0.63 MI. N. JCT. US70BUS (Lat: 35.398814,  Lng: -78.008300),  Route carried "under" structure: US 70,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: I795S
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 108.174,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 1910333,  Location: 0.63 MI. N. JCT. US70BUS (Lat: 35.398747,  Lng: -78.008061),  Route carried "under" structure: US 70,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2014),  Truck Traffic: 12%,  Features Intersected: I795N
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 108.174,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 1910333,  Location: 0.63 MI. N. JCT. US70BUS (Lat: 35.398747,  Lng: -78.008061),  Route carried "under" structure: US 70,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2018),  Truck Traffic: 12%,  Features Intersected: I795N
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 108.174,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 1910334,  Location: 3.49 MI. S. JCT. SR1336 (Lat: 35.421261,  Lng: -77.996828),  Route carried "under" structure: Interstate 795,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 8,250 (year 2018),  Truck Traffic: 16%,  Features Intersected: SR1300
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 7.193,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 49.6m (162.7ft)

Find on map >>   Show street view

Structure Number: 1910334,  Location: 3.49 MI. S. JCT. SR1336 (Lat: 35.421261,  Lng: -77.996828),  Route carried "under" structure: Interstate 795,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 8,250 (year 2018),  Truck Traffic: 16%,  Features Intersected: SR1300
Minimum Vertical Clearance: 5.58m (18.31ft),  Kilometerpoint: 7.193,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 49.6m (162.7ft)

Find on map >>   Show street view

Structure Number: 1910335,  Location: 0.41M. E. JCT SR1300 (Lat: 35.430100,  Lng: -77.989158),  Route carried "under" structure: Interstate 795,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 9,250 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1313
Minimum Vertical Clearance: 5.35m (17.55ft),  Kilometerpoint: 6.980,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.6m (139.8ft)

Find on map >>   Show street view

Structure Number: 1910335,  Location: 0.41M. E. JCT SR1300 (Lat: 35.430100,  Lng: -77.989158),  Route carried "under" structure: Interstate 795,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 9,250 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1313
Minimum Vertical Clearance: 5.43m (17.81ft),  Kilometerpoint: 6.980,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.6m (139.8ft)

Find on map >>   Show street view

Structure Number: 1910335,  Location: 0.41M. E. JCT SR1300 (Lat: 35.430100,  Lng: -77.989158),  Route carried "under" structure: Ramp Interstate 795,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 4,625 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1313,  Facility Carried by Structure: NC44E,RAMP
Minimum Vertical Clearance: 5.91m (19.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.6m (139.8ft)

Find on map >>   Show street view

Structure Number: 1910335,  Location: 0.41M. E. JCT SR1300 (Lat: 35.430100,  Lng: -77.989158),  Route carried "under" structure: Ramp Interstate 795,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 4,625 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1313
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 6.980,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.6m (139.8ft)

Find on map >>   Show street view

Structure Number: 1910336,  Location: 4 MI. S. JCT. SR1002 (Lat: 35.442339,  Lng: -77.984564),  Route carried "under" structure: State highway 1316,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: I-795 SBL
Minimum Vertical Clearance: 4.59m (15.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 1910337,  Location: 4 MI. S. JCT. SR1002 (Lat: 35.442331,  Lng: -77.984325),  Route carried "under" structure: State highway 1316,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 1,500 (year 2016),  Truck Traffic: 7%,  Features Intersected: I795N
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 1910353,  Location: 3.81 MI. E. JCT. NC581 (Lat: 35.427461,  Lng: -77.991450),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70W. BYP
Minimum Vertical Clearance: 5.48m (17.98ft),  Kilometerpoint: 6.797,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 1910353,  Location: 3.81 MI. E. JCT. NC581 (Lat: 35.427461,  Lng: -77.991450),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70W. BYP
Minimum Vertical Clearance: 5.53m (18.14ft),  Kilometerpoint: 6.797,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 1910354,  Location: 0.7 MI. W. JCT US117 (Lat: 35.427258,  Lng: -77.991625),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70E. BYP,NC44E
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 6.797,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 1910354,  Location: 0.7 MI. W. JCT US117 (Lat: 35.427258,  Lng: -77.991625),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70E. BYP,NC44E
Minimum Vertical Clearance: 5.53m (18.14ft),  Kilometerpoint: 6.797,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 1910355,  Location: 0.2 MI. W. JCT. I795 (Lat: 35.427811,  Lng: -77.994464),  Route carried "under" structure: State highway 4,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: I795S,US70E,RAMP
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 108.296,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Find on map >>   Show street view

Structure Number: 1910355,  Location: 0.2 MI. W. JCT. I795 (Lat: 35.427811,  Lng: -77.994464),  Route carried "under" structure: State highway 44,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 13,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: I795S,US70E,RAMP
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 108.296,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Find on map >>   Show street view

Structure Number: 1910356,  Location: 0.7MI W JCT US70BYP/NC117 (Lat: 35.425453,  Lng: -77.993167),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70BYP,RAMP
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 7.132,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Find on map >>   Show street view

Structure Number: 1910356,  Location: 0.7MI W JCT US70BYP/NC117 (Lat: 35.425453,  Lng: -77.993167),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70BYP,RAMP
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 7.132,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Find on map >>   Show street view

Structure Number: 1910357,  Location: 3.83MI. E. JCT.US70/NC581 (Lat: 35.424497,  Lng: -77.994008),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70W.BYP.RAMP
Minimum Vertical Clearance: 6.29m (20.64ft),  Kilometerpoint: 7.132,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 1910357,  Location: 3.83MI. E. JCT.US70/NC581 (Lat: 35.424497,  Lng: -77.994008),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70W.BYP.RAMP
Minimum Vertical Clearance: 5.30m (17.39ft),  Kilometerpoint: 7.132,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Find on map >>   Show street view

Structure Number: 1910357,  Location: 3.83MI. E. JCT.US70/NC581 (Lat: 35.424497,  Lng: -77.994008),  Route carried "under" structure: Interstate 795,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: US70W.BYP.RAMP
Minimum Vertical Clearance: 5.30m (17.39ft),  Kilometerpoint: 7.132,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 51.8m (169.9ft)

Discuss Goldsboro, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.