Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Stony Ridge, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 47Number of bridges
  • 374ft / 114mTotal length
  • $338,617,000Total costs
  • 407,757Total average daily traffic
  • 100,101Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Stony Ridge
  • No street view available for this location

New bridges in Stony Ridge, OH - historical statistics
  • New bridges - historical statistics
  • 51940-1949
  • 131950-1959
  • 31960-1969
  • 41970-1979
  • 11980-1989
  • 101990-1999
  • 82000-2009
  • 22010-2019
  • 12020-2022
Reconstructed bridges in Stony Ridge, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 61980-1989
  • 11990-1999
  • 32000-2009
  • 22010-2019
Average Bridge Daily Traffic in Stony Ridge, OH
Average Bridge Truck Traffic in Stony Ridge, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 28.1%Excellent
  • 28.1%Very good
  • 25.0%Good
  • 12.5%Satisfactory
  • 6.3%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 25.0%Excellent
  • 37.5%Very good
  • 18.8%Good
  • 12.5%Satisfactory
  • 6.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 12.5%Excellent
  • 50.0%Very good
  • 28.1%Good
  • 9.4%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 10.7%Very good
  • 53.6%Good
  • 21.4%Satisfactory
  • 10.7%Fair
  • 3.6%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Very good
  • 60.0%Good
  • 20.0%Satisfactory
Find on map >>   Show street view

Structure Number: 8701121,  Location: 0.2 Mi. W OF OREGON RD (Lat: 41.524489,  Lng: -83.541489),  Route carried "on" structure: US 20,  Year Built: 2002,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 12,941 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 17,962 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CEDAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.477,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft)

Condition: Channel: Fair,  Culverts: Very good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 8701237,  Location: 0.48 mi. West of SR 420 (Lat: 41.496039,  Lng: -83.474350),  Route carried "on" structure: US 20,  Year Built: 1941,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 19.84m (65.09ft),  Average Daily Traffic: 8,506 (year 2015),  Truck Traffic: 12%,  Average Future Daily Traffic: 11,806 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CSX RR-PACKER CR-TWP 111
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.866,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8704988,  Location: 1.71 mi West of IR80/IR90 (Lat: 41.514839,  Lng: -83.468611),  Route carried "on" structure: State highway 163,  Year Built: 1962,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 2,569 (year 2015),  Truck Traffic: 16%,  Average Future Daily Traffic: 3,566 (year 2035),  Design Load: H 15,  Features Intersected: CRANE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.235,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 870538,  Location: 1.02 mi. NW of SR 582 (Lat: 41.470361,  Lng: -83.569069),  Route carried "on" structure: State highway 199,  Year Built: 1979,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 3,010 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,178 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: PACKER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.318,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8705755,  Location: 1/4 MI N OF OHIO TURNPIKE (Lat: 41.529489,  Lng: -83.463189),  Route carried "on" structure: Interstate 280,  Year Built: 1999,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 25,704 (year 2015),  Truck Traffic: 23%,  Average Future Daily Traffic: 35,677 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CRANE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 8706433,  Location: 0.4 Mi. N. OF USR 20 (Lat: 41.496769,  Lng: -83.463411),  Route carried "on" structure: State highway 420,  Year Built: 1998,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 408 (year 2015),  Truck Traffic: 36%,  Average Future Daily Traffic: 566 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: PACKER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.352,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 5.7m (18.7ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 8706468,  Location: JCT SR 420 & USR 20 (Lat: 41.491431,  Lng: -83.463531),  Route carried "on" structure: State highway 420,  Year Built: 2006,  Status: Open,  Structure Length: 4.60m (15.09ft),  Average Daily Traffic: 456 (year 2019),  Truck Traffic: 26%,  Average Future Daily Traffic: 700 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: US 20
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.756,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8706476,  Location: JCT SR 420 & US 20 (Lat: 41.491531,  Lng: -83.463769),  Route carried "on" structure: State highway 420,  Year Built: 2006,  Status: Open,  Structure Length: 4.60m (15.09ft),  Average Daily Traffic: 4,944 (year 2019),  Truck Traffic: 20%,  Average Future Daily Traffic: 6,700 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: US 20
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.756,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8706484,  Location: 0.3MI EAST OF EXIT 71 (Lat: 41.523969,  Lng: -83.463589),  Route carried "on" structure: Ramp State highway 420,  Year Built: 1954,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 9,427 (year 2019),  Truck Traffic: 41%,  Average Future Daily Traffic: 13,809 (year 2039),  Design Load: HS 20,  Features Intersected: I280 / SR420,  Facility Carried by Structure: TPK EXIT 71 RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.361,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Toll Authority,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8729522,  Location: 2.8MI EAST OF EXIT 64 (Lat: 41.544669,  Lng: -83.528631),  Route carried "on" structure: County highway C0321,  Year Built: 1997,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 660 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: I80 OHIO TPK,  Facility Carried by Structure: TRACY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.660,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 872953,  Location: 3.7MI WEST OF EXIT 71 (Lat: 41.543261,  Lng: -83.524819),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 31,648 (year 2015),  Truck Traffic: 27%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20,  Features Intersected: CEDAR CREEK,  Facility Carried by Structure: I80 OH TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.015,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.9m (52.2ft),  Curb-To-Curb Width: 37.5m (123.0ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8729581,  Location: 2.9MI WEST OF EXIT 71 (Lat: 41.539911,  Lng: -83.511361),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 9.36m (30.71ft),  Average Daily Traffic: 31,648 (year 2015),  Truck Traffic: 27%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20,  Features Intersected: CR10-CSX TRAN RR,  Facility Carried by Structure: I80 OHIO TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.189,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 37.5m (123.0ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8729654,  Location: 1.5MI WEST OF EXIT 71 (Lat: 41.534281,  Lng: -83.483469),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 31,648 (year 2015),  Truck Traffic: 27%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20,  Features Intersected: CSX TRAN RR,  Facility Carried by Structure: I80 OH TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.636,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 34 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 37.5m (123.0ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8729689,  Location: 1.4MI WEST OF EXIT 71 (Lat: 41.533550,  Lng: -83.482211),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 31,648 (year 2015),  Truck Traffic: 27%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20,  Features Intersected: CUMMINS RD,  Facility Carried by Structure: I80 OH TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.732,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 37.5m (123.0ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8729719,  Location: 1.3MI WEST OF EXIT 71 (Lat: 41.532419,  Lng: -83.479800),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 31,648 (year 2015),  Truck Traffic: 27%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: HENRY DITCH,  Facility Carried by Structure: I80 OH TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.990,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 37.8m (124.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Poor,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 77.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 8729743,  Location: 0.9MI WEST OF EXIT 71 (Lat: 41.529200,  Lng: -83.472581),  Route carried "on" structure: County highway C0111,  Year Built: 1997,  Status: Open,  Structure Length: 7.28m (23.88ft),  Average Daily Traffic: 1,465 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: I80 OHIO TPK,  Facility Carried by Structure: LEMOYNE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.682,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Toll Authority,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8729751,  Location: 0.4MI WEST OF EXIT 71 (Lat: 41.526639,  Lng: -83.465150),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 31,648 (year 2015),  Truck Traffic: 27%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20,  Features Intersected: CRANE CREEK DITCH,  Facility Carried by Structure: I80 OH TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.374,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 37.8m (124.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 8729786,  Location: 0.3MI WEST OF EXIT 71 (Lat: 41.525911,  Lng: -83.463219),  Route carried "on" structure: Interstate 80K,  Year Built: 1954,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 7.89m (25.89ft),  Average Daily Traffic: 31,648 (year 2015),  Truck Traffic: 27%,  Average Future Daily Traffic: 43,927 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: SR 420,  Facility Carried by Structure: I80 OH TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.535,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 32 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 37.4m (122.7ft),  Out-to-Out Width: 38.3m (125.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8730014,  Location: 0.36 MI. E. OF TRACY RD. (Lat: 41.543969,  Lng: -83.523661),  Route carried "on" structure: County highway T065B,  Year Built: 2017,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 470 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 470 (year 2035),  Design Load: HL 93,  Features Intersected: CEDAR CREEK LATCHA ROAD,  Facility Carried by Structure: LATCHA ROAD(T-65)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8730015,  Location: 0.16 MI S OF OH TURNPIKE (Lat: 41.540881,  Lng: -83.528550),  Route carried "on" structure: County highway C321B,  Year Built: 2015,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 660 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 916 (year 2035),  Design Load: HL 93,  Features Intersected: CEDAR CREEK TRACY RD,  Facility Carried by Structure: TRACY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8732264,  Location: 0.75 ML N OF DOWLING RD (Lat: 41.488111,  Lng: -83.568061),  Route carried "on" structure: County highway C009A,  Year Built: 1975,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 587 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 815 (year 2035),  Design Load: HS 20,  Features Intersected: DITCH 2250 LIME CITY RD,  Facility Carried by Structure: LIME CITY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.2m (23.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 58.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8732647,  Location: 0.55 ML N OF DOWLING RD (Lat: 41.487081,  Lng: -83.511900),  Route carried "on" structure: County highway C010B,  Year Built: 1997,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 588 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 816 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: 2 ROOT CRK.STONY RIDGE R,  Facility Carried by Structure: STONY RIDGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.65m (5.41ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $73,000,  Roadway Improvement Cost: $11,000,  Total Project Cost: $90,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 873276,  Location: 0.65 MI. N. OF S.R. 20 (Lat: 41.521089,  Lng: -83.510989),  Route carried "on" structure: County highway C010C,  Year Built: 1974,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 877 (year 2015),  Truck Traffic: 11%,  Average Future Daily Traffic: 1,217 (year 2035),  Design Load: HS 20,  Features Intersected: HENRY DITCH E. BROADWAY,  Facility Carried by Structure: EAST BROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.2m (33.5ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Excellent,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8732965,  Location: 0.90 ML S OF S.R. 20 (Lat: 41.491419,  Lng: -83.492811),  Route carried "on" structure: County highway T011B,  Year Built: 1958,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 1.79m (5.87ft),  Average Daily Traffic: 1,149 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,595 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: TWO ROOT CREEK LUCKEY RD,  Facility Carried by Structure: LUCKEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.68m (5.51ft),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Critical Feature Inspection Date: July 2020,  Total Project Cost: $337,918,000,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 873424,  Location: 0.76 MI. N. OF S.R. 20 (Lat: 41.498789,  Lng: -83.453831),  Route carried "on" structure: County highway C015H,  Year Built: 1986,  Status: Open,  Structure Length: 2.03m (6.66ft),  Average Daily Traffic: 977 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,356 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: 2 ROOT CRK PEMBERVILLE R,  Facility Carried by Structure: PEMBERVILLE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 8735182,  Location: 0.72 ML W OF TRACY RD (Lat: 41.477781,  Lng: -83.542981),  Route carried "on" structure: County highway T017B,  Year Built: 1992,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 410 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 569 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: TWO ROOT CREEK DOWLING R,  Facility Carried by Structure: DOWLING ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 8744203,  Location: 0.40 ML E OF LUCKY RD (Lat: 41.529381,  Lng: -83.483439),  Route carried "on" structure: County highway T064A,  Year Built: 1963,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 260 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 361 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: HENRY CREEK HANLEY ROAD,  Facility Carried by Structure: HANLEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8747947,  Location: .6 mile N. of S.R. 582 (Lat: 41.469439,  Lng: -83.571111),  Route carried "on" structure: County highway T93B,  Year Built: 2020,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 161 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 216 (year 2040),  Design Load: HL 93,  Features Intersected: Packer Creek,  Facility Carried by Structure: Anderson Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.064,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8749434,  Location: 0.10 MI N OF S.R. 20 (Lat: 41.524969,  Lng: -83.538411),  Route carried "on" structure: County highway C107A,  Year Built: 1941,  Year Reconstructed: 1987,  Status: Posted for load,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 2,630 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 3,650 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CEDAR CREEK OREGON ROAD,  Facility Carried by Structure: OREGON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 8749752,  Location: 0.40 MI S OF S.R. 20 (Lat: 41.521639,  Lng: -83.548139),  Route carried "on" structure: County highway T108A,  Year Built: 1960,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 364 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 505 (year 2035),  Design Load: HS 20,  Features Intersected: CEDAR CREEK AULT RD,  Facility Carried by Structure: AULT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.5m (57.4ft),  Curb-To-Curb Width: 7.1m (23.3ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Good,  Operating Rating: 77.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 8750084,  Location: 0.20 ML W OF LEMOYNE RD (Lat: 41.495281,  Lng: -83.474081),  Route carried "on" structure: County highway T111C,  Year Built: 1974,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 1,079 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,498 (year 2035),  Design Load: HS 20,  Features Intersected: D1963 S.ACCESS LEMOYNE R,  Facility Carried by Structure: LEMOYNE RD W. SIDE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.3m (53.5ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 875013,  Location: UNDER S.R. 20 OVER-PASS (Lat: 41.495561,  Lng: -83.473211),  Route carried "on" structure: County highway T111C,  Year Built: 1943,  Status: Posted for load,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 1,079 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,498 (year 2035),  Features Intersected: TWO ROOT CREEK LEMOYNE R,  Facility Carried by Structure: LEMOYNE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.064,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8750203,  Location: 0.02 ML W OF LEMOYNE RD (Lat: 41.495739,  Lng: -83.472600),  Route carried "on" structure: County highway T111C,  Year Built: 2005,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 1,079 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,498 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: D1963 N ACCESS LEMOYNE R,  Facility Carried by Structure: LEYMOYNE RD E SIDE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.4m (63.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.07m (6.79ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $180,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $200,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8750262,  Location: 0.37 MI N OF S.R. 20 (Lat: 41.501531,  Lng: -83.473161),  Route carried "on" structure: County highway T111C,  Year Built: 2009,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 1,131 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,570 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: CRANE CREEK LEMOYNE ROA,  Facility Carried by Structure: LEMOYNE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.097,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8757526,  Location: .18 ML. E. OF E. BROADWAY (Lat: 41.521989,  Lng: -83.508181),  Route carried "on" structure: County highway T308A,  Year Built: 2000,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 550 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 763 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: HENRY DCH.#2212 LIBBEY R,  Facility Carried by Structure: LIBBEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 8758239,  Location: 2.4 MI.SOUTH OF U.S.R. 20 (Lat: 41.482900,  Lng: -83.528911),  Route carried "on" structure: County highway T321A,  Year Built: 1990,  Status: Open,  Structure Length: 1.59m (5.22ft),  Average Daily Traffic: 452 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 627 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: TWO ROOT CREEK TRACY ROA,  Facility Carried by Structure: TRACY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.34m (4.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $186,000,  Roadway Improvement Cost: $21,000,  Total Project Cost: $207,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8758352,  Location: 0.3 MI.SOUTH OF U.S.R.20 (Lat: 41.515061,  Lng: -83.528731),  Route carried "on" structure: County highway T321A,  Year Built: 1998,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 903 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,253 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: DCH2212CRANE CRK TRACY R,  Facility Carried by Structure: TRACY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.22m (4.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $182,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $202,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8701237,  Location: 0.48 mi. West of SR 420 (Lat: 41.496039,  Lng: -83.474350),  Route carried "under" structure: County highway T0111,  Year Built: 1941,  Structure Length: 0. m,  Average Daily Traffic: 1,109 (year 2018),  Truck Traffic: 14%,  Features Intersected: USR 20 (GEN MCPHERSON HY,  Facility Carried by Structure: Lemoyne Rd.
Minimum Vertical Clearance: 7.57m (24.84ft),  Kilometerpoint: 10.157,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 8701237,  Location: 0.48 mi. West of SR 420 (Lat: 41.496039,  Lng: -83.474350),  Route carried "under" structure: County highway T0459,  Year Built: 1941,  Structure Length: 0. m,  Average Daily Traffic: 150 (year 2018),  Features Intersected: USR 20 (GEN MCPHERSON HY,  Facility Carried by Structure: Railroad St.
Minimum Vertical Clearance: 7.47m (24.51ft),  Kilometerpoint: 0.377,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Discuss Stony Ridge, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.