- Water Quality Recording (3 violations)
TSSP&S 265.204 (Eff Oct 1, 1999) - Water Quality, pages 36 - 39 and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Pool/spa operators and managers shall maintain the quality of water in all pools and spas to comply with City of Fort Worth Ordinances and the State Standard.
Thank you for maintaining good pool water quality. The current free available chlorine level is 3 PPM. Thank you for maintaining good pool water quality. The current pH level is 7.0. Thank you for maintaining good pool water quality. The current cyanuric acid level is 70ppm.
Corrective action: Good job. Good job. Good job.
- Waste Water Disposal
TSSP&S 265.196 (Eff Oct 1, 1999) - Waste Water Disposal, page 48; TDSPSPC 337.77 (Eff Jun 13, 1965) and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Waste water shall be released in compliance with TCEQ requirements, City of Fort Worth Ordinances and the State Standard.
There is a direct mechanical connection between the wastewater disposal system and a drain or recirculation system. Air gap is inadequate.
Corrective action: Backwash or drain water shall be discharged through an air gap at least two times the diameter of the discharge pipe located above the overflow level. A splash screen barrier can be used to prevent water splashing.
- Handholds Specific Safety Features
TSSP&S 265.199 (Eff Oct 1, 1999) - Specific Safety Features, pages 52 - 60; TDSPSPC 337.80,TDSPSPC 337.93,TDSPSPC 337.96 (Eff Jun 13, 1965) and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). Safety features and equipment shall be designed, constructed, installed and maintained to comply with all applicable provisions of City of Fort Worth Ordinances and the State Standard.
Properly designed "NO DIVING" markings are not provided. The no diving sign is not in 4 inch letters.
Corrective action: At class C & D pools where no lifeguard is provided, a securely mounted sign which is readily visible to swimmers with the warning words "NO DIVING" and the international symbol for no diving with letters at least four inches high shall be placed in plain view.
- Fort Worth Ordinance
A conspicuously posted sign stating "Diaper Changing in the pool/spa area is Prohibited" is not provided.
Corrective action: A sign visible from the pool or spa enclosure shall state in letters at least 2" in height "Diaper Changing in the Pool/Spa area is Prohibited".
- Circulation System
TSSP&S 265.187 (Eff Oct 1, 1999) - Circulation System, pages 33-35; TDSPSPC 337.66 (Eff Jun 13, 1965) and FW Ordinance #12156-Sec 16.459-462 (Sep 12, 1995). All circulation systems shall be designed, constructed, installed, maintained and operated to comply with all applicable provisions of the City of Fort Worth Ordinances and the State Standard.
Exposed piping is not labeled to identify the piping function and direction of flow.
Corrective action: Exposed piping shall be labeled to identify the piping function and direction of flow. The name of the liquid or gas and arrows indicating direction of flow shall be permanently indicated on the pipe.
|