- Critical: Backflow Prevention
- Comment:
- CORRECTED BY PROVIDING THE PROPER AIR GAP FOR THE ICE BIN AND ICE MACHINE DRAIN LINES.
- General violation description:
- 5-402.11 - (A) Except as specified in (B) and (C) of this section, a direct connection may not exist between the SEWAGE system and a drain originating from EQUIPMENT in which FOOD, portable EQUIPMENT, or UTENSILS are placed. (B) If allowed by LAW, a WAREWASHING machine may have a direct connection between its waste outlet and a floor drain when the machine is located within 1.5 m (5 feet) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap. (C) If allowed by LAW, a WAREWASHING or culinary sink may have a direct connection.
- Critical: Capacity
- Comment:
- CORRECTED BY INSTALLING A NEW ELEMENT ON THE EXISTING HOT WATER UNIT TO HAVE 6 KW EACH WORKING SIMULTANEOUSLY TO PROVIDE 12 KW AND 50 GPH RECOVERY.
- General violation description:
- 5-103.11 - (A) The water source and system shall be of sufficient capacity to meet the peak water demands of the FOOD ESTABLISHMENT. (B) Hot water generation and distribution systems shall be sufficient to meet the peak hot water demands throughout the FOOD ESTABLISHMENT.
- Critical: System Maintained in Good Repa
- Comment:
- CORRECTED BY INSTALLING THE 1022 BACKFLOW PREVENTOR HIGHER ON THE WATER LINE SO IT IS NOT LAYING ON THE DRAIN BOWL OR FLOOR.
- General violation description:
- 5-205.15 - A PLUMBING SYSTEM shall be: (A) Repaired according to LAW
- Fixed Equipment, Spacing or Se
- Comment:
- CORRECTED BY SEALING ALL NOTED EQUIPMENT TO THE COUNTERS AND WALLS. ALSO THE DRAIN BOWL WAS CUT TO BE FLUSH WITH THE FLOOR SO THERE IS NO DUCT TAPE AND IT IS SEALED.
- General violation description:
- 4-402.11 - (A) EQUIPMENT that is fixed because it is not EASILY MOVABLE shall be installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, and above the EQUIPMENT
- Floor and Wall Junctures, Cove
- Comment:
- CORRECTED BY INSTALLING COVE BASE IN REQUIRED AREAS.
- General violation description:
- 6-201.13 - (A) In FOOD ESTABLISHMENTS in which cleaning methods other than water flushing are used for cleaning floors, the floor and wall junctures shall be coved and closed to no larger than 1 mm (one thirty-second inch). (B) The floors in FOOD ESTABLISHMENTS in which water flush cleaning methods are used shall be provided with drains and be graded to drain, and the floor and wall junctures shall be coved and SEALED.
- Nonfood-Contact Surfaces
- Comment:
- CORRECTED BY SEALING ALL BARE WOOD TO BE SMOOTH, NON-ABSORBENT AND EASILY CLEANABLE.
- General violation description:
- 4-202.16 - NonFOOD-CONTACT SURFACES shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
02/13/2015 | Follow-up |
Restaurant representatives - add corrected or new information about Biggby Coffee, 15552outhfield Rd, Allen Park, MI 48101 »