- Critical: Approved
- Comment:
- OBSERVED THAT THE DRAINLINE HAS BEEN INSTALLED TO AN AIR GAP FROM THE COOLER. CORRECTED.
- General violation description:
- 5-201.11 - (A) A PLUMBING SYSTEM and hoses conveying water shall be constructed and repaired with APPROVED materials according to LAW. (B) A water filter shall be made of SAFE MATERIALS.
- Critical: Backflow Prevention Device, Wh
- Comment:
- OBSERVED THAT AN RPZ HAS BEEN INSTALLED ON THE WATER LINE DESIGNATED FOR THE POWER WASH UNIT. CORRECTED.
- General violation description:
- 5-203.14 - A PLUMBING SYSTEM shall be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the FOOD ESTABLISHMENT, including on a hose bibb if a hose is attached or on a hose bibb if a hose is not attached and backflow prevention is required by LAW, by: (A) Providing an air gap as specified under 5-202.13
- Critical: Sanitizing Solutions, Testing
- Comment:
- OBSERVED THAT THE TEST IS PRESENT AND OPERATOR DEMONSTRATED USE OF THEM IN THE 3-COMPARTMENT SINK. CORRECTED.
- General violation description:
- 4-302.14 - A test kit or other device that accurately measures the concentration in MG/L of SANITIZING solutions shall be provided. (Pf)
- Covering Receptacles
- Comment:
- OBSERVED THAT THE DUMPSTER HAS BEEN INSTALLED.
- General violation description:
- 5-501.113 - Receptacles and waste handling units for REFUSE, recyclables, and returnables shall be kept covered: (A) Inside the FOOD ESTABLISHMENT if the receptacles and units: (1) Contain FOOD residue and are not in continuous use
- Drying Mops
- Comment:
- OBSERVED THAT THE MOP HANGER HAS BEEN INSTALLED. CORRECTED.
- General violation description:
- 6-501.16 - After use, mops shall be placed in a position that allows them to air-dry without soiling walls, EQUIPMENT, or supplies.
- Fixed Equipment, Spacing or Se
- Comment:
- OBSERVED LEGS HAVE BEEN PLACED ON THE COOLER MAKING IT EASILY CLEANABLE. CORRECTED.
- General violation description:
- 4-402.11 - (A) EQUIPMENT that is fixed because it is not EASILY MOVABLE shall be installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, and above the EQUIPMENT
- Floor and Wall Junctures, Cove
- Comment:
- OBSERVED THAT THE COVE BASE HAS BEEN INSTALLED AT THE BASE OF THE CABINETRY. CORRECTED.
- General violation description:
- 6-201.13 - (A) In FOOD ESTABLISHMENTS in which cleaning methods other than water flushing are used for cleaning floors, the floor and wall junctures shall be coved and closed to no larger than 1 mm (one thirty-second inch). (B) The floors in FOOD ESTABLISHMENTS in which water flush cleaning methods are used shall be provided with drains and be graded to drain, and the floor and wall junctures shall be coved and SEALED.
- Nonfood-Contact Surfaces
- Comment:
- OBSERVED THAT THE WOOD HAS BEEN COVERED WITH FRP MATERIAL AND SEALED. CORRECTED.
- General violation description:
- 4-101.19 - NonFOOD-CONTACT SURFACES of EQUIPMENT that are exposed to splash, spillage, or other FOOD soiling or that require frequent cleaning shall be constructed of a CORROSION-RESISTANT, nonabsorbent, and SMOOTH material.
- Nonfood-Contact Surfaces
- Comment:
- OBSERVED THAT THE OPENINGS AROUND PIPING HAVE BEEN ELIMINATED AND SEALED AND UNUSED PIPING HAS BEEN ELIMINATED. CORRECTED.
- General violation description:
- 4-202.16 - NonFOOD-CONTACT SURFACES shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
- Outer Openings, Protected
- Comment:
- OBSERVED THAT A SELF-CLOSING DEVICE HAS BEEN INSTALLED ON THE BACK DOOR. CORRECTED.
- General violation description:
- 6-202.15 - (A) Except as specified in ## (B), (C), and (E) and under # (D) of this section, outer openings of a FOOD ESTABLISHMENT shall be protected against the entry of insects and rodents by: (1) Filling or closing holes and other gaps along floors, walls, and ceilings
|
04/01/2015 | Follow-up |
Restaurant representatives - add corrected or new information about North Center Brewing Co. Llc., 410 N. Center Street, Northville, MI 48167 »