Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for East Peoria, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 111Number of bridges
  • 1,686ft / 514mTotal length
  • $7,384,000Total costs
  • 1,444,575Total average daily traffic
  • 118,083Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for East Peoria
  • No street view available for this location

New bridges in East Peoria, IL - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 41930-1939
  • 151950-1959
  • 221960-1969
  • 91970-1979
  • 131980-1989
  • 91990-1999
  • 302000-2009
  • 62010-2019
  • 22020-2022
Reconstructed bridges in East Peoria, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 41980-1989
  • 41990-1999
  • 42000-2009
  • 22010-2019
Average Bridge Daily Traffic in East Peoria, IL
Average Bridge Truck Traffic in East Peoria, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 1.5%Excellent
  • 1.5%Very good
  • 16.9%Good
  • 26.2%Satisfactory
  • 41.5%Fair
  • 9.2%Poor
  • 3.1%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 1.5%Excellent
  • 16.9%Very good
  • 13.8%Good
  • 20.0%Satisfactory
  • 24.6%Fair
  • 21.5%Poor
  • 1.5%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 1.5%Excellent
  • 16.9%Very good
  • 43.1%Good
  • 21.5%Satisfactory
  • 10.8%Fair
  • 3.1%Poor
  • 1.5%Serious
  • 1.5%Critical
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.3%Excellent
  • 29.3%Very good
  • 31.7%Good
  • 19.5%Satisfactory
  • 2.4%Fair
  • 4.9%Poor
  • 4.9%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Very good
  • 37.5%Good
  • 25.0%Fair
  • 12.5%Poor
Find on map >>   Show street view

Structure Number: 900153,  Location: EAST PEORIA (Lat: 40.679772,  Lng: -89.580025),  Route carried "on" structure: Other road ,  Year Built: 2004,  Status: Open,  Structure Length: 44.34m (145.47ft),  Average Daily Traffic: 2,600 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 4,408 (year 2032),  Design Load: HS 20,  Features Intersected: RMPS H-1,4 DIVR CHAN,  Facility Carried by Structure: I74 RP 1.05(H-3)
Minimum Vertical Clearance: 30.40m (99.74ft),  Kilometerpoint: 0.483,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 10074040,  Subroute: 50),  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 71.7m (235.2ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900155,  Location: 0.03 MI W OF US 116 (Lat: 40.670592,  Lng: -89.574275),  Route carried "on" structure: Other road ,  Year Built: 2005,  Status: Open,  Structure Length: 19.46m (63.85ft),  Average Daily Traffic: 4,700 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,408 (year 2032),  Design Load: HS 20,  Features Intersected: MAIN ST & RAMP 1.71,  Facility Carried by Structure: 74EB TO EB CAMP ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.241,  Lanes on structure: 1,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 10074040,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 42.1m (138.1ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900156,  Location: 0.02 MI NE 74 (Lat: 40.669814,  Lng: -89.572911),  Route carried "on" structure: Other road ,  Year Built: 2006,  Status: Open,  Structure Length: 21.03m (69.00ft),  Average Daily Traffic: 5,200 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,590 (year 2032),  Design Load: HS 20,  Features Intersected: MAINST&WB74TONBSB116,  Facility Carried by Structure: CAMP ST TO WB 74
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.595,  Lanes on structure: 1,  Lanes under structure: 9,  Base Highway Network: Yes (Inventory Route: 10074040,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 57.5m (188.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900157,  Location: .25 MI E JCT US 116 (Lat: 40.666817,  Lng: -89.572053),  Route carried "on" structure: Other road ,  Year Built: 2005,  Status: Open,  Structure Length: 5.84m (19.16ft),  Average Daily Traffic: 4,700 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,408 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: WB US 150,  Facility Carried by Structure: EXIT TO CAMP ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.708,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes (Inventory Route: 10074040,  Subroute: 70),  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900158,  Location: .25 MI W OF ILL 116 (Lat: 40.672242,  Lng: -89.575225),  Route carried "on" structure: Interstate 74,  Year Built: 2005,  Status: Open,  Structure Length: 5.85m (19.19ft),  Average Daily Traffic: 52,100 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 64,285 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ALTORFER LA&TP&W RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 155.539,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.1m (95.5ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.7m (84.3ft),  Curb-To-Curb Width: 29.1m (95.5ft),  Out-to-Out Width: 30.0m (98.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900159,  Location: .25 MI W OF ILL 116 (Lat: 40.672158,  Lng: -89.575164),  Route carried "on" structure: Interstate 74,  Year Built: 2006,  Status: Open,  Structure Length: 5.85m (19.19ft),  Average Daily Traffic: 26,050 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 32,143 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ALTORFER LA&TP&W RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 155.555,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.9m (78.4ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.7m (84.3ft),  Curb-To-Curb Width: 23.9m (78.4ft),  Out-to-Out Width: 24.5m (80.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 77.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 90016,  Location: ILL 116 INTERCHANGE (Lat: 40.670308,  Lng: -89.573786),  Route carried "on" structure: Interstate 74,  Year Built: 2006,  Status: Open,  Structure Length: 5.90m (19.36ft),  Average Daily Traffic: 18,650 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 22,683 (year 2032),  Design Load: HS 20,  Features Intersected: ILL 116 (MAIN ST)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 155.909,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.5m (96.8ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900161,  Location: ILL 116 INTERCHANGE (Lat: 40.670200,  Lng: -89.573708),  Route carried "on" structure: Interstate 74,  Year Built: 2005,  Status: Open,  Structure Length: 5.90m (19.36ft),  Average Daily Traffic: 37,300 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 45,365 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: ILL 116(MAIN ST)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 155.925,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.9m (55.4ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.1m (95.5ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 19.6m (64.3ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900162,  Location: ILL 8 INTER,E PEORIA (Lat: 40.663875,  Lng: -89.569097),  Route carried "on" structure: Interstate 74,  Year Built: 2005,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 19,150 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 22,360 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: E WASHINGTON, TAYLOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 156.714,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.9m (55.4ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.8m (114.2ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900163,  Location: ILL 8 INTER,E PEORIA (Lat: 40.663772,  Lng: -89.569031),  Route carried "on" structure: Interstate 74,  Year Built: 2006,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 19,150 (year 2021),  Truck Traffic: 11%,  Average Future Daily Traffic: 22,360 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: E WASHINGTON, TAYLOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 156.730,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.8m (48.6ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900164,  Location: US 150 E PEORIA (Lat: 40.665283,  Lng: -89.540997),  Route carried "on" structure: US 150,  Year Built: 1998,  Status: Open,  Structure Length: 2.31m (7.58ft),  Average Daily Traffic: 6,150 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,310 (year 2032),  Design Load: HS 20,  Features Intersected: LITTLE FARM CREEK,  Facility Carried by Structure: MEADOWS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 155.603,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900171,  Location: N OF ILL 116 (Lat: 40.735953,  Lng: -89.521864),  Route carried "on" structure: State highway 26,  Year Built: 2004,  Status: Open,  Structure Length: 3.83m (12.57ft),  Average Daily Traffic: 6,000 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 8,009 (year 2032),  Design Load: HS 20,  Features Intersected: TEN MILE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.676,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.1m (62.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 85.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900173,  Location: 2.5 MI W OF MORTON (Lat: 40.604603,  Lng: -89.565422),  Route carried "on" structure: State highway 98,  Year Built: 2007,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 3,400 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,246 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: LICK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.051,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.0m (85.3ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 52.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900175,  Location: MEADOWS AVE E. PEO. (Lat: 40.666100,  Lng: -89.550961),  Route carried "on" structure: US 150,  Year Built: 2010,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 8,350 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 8,923 (year 2032),  Design Load: HS 20,  Features Intersected: LITTLE FARM CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 154.750,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.6m (67.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 26.5m (86.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 65.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900176,  Location: 1.7 MI E OF ILL 8 (Lat: 40.662789,  Lng: -89.532161),  Route carried "on" structure: US 150,  Year Built: 2009,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 5,900 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,934 (year 2032),  Design Load: HS 20,  Features Intersected: LITTLE FARM CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 156.408,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.4m (60.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 80.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900179,  Location: N OF ILL 26 (Lat: 40.738244,  Lng: -89.515894),  Route carried "on" structure: State highway 116,  Year Built: 2014,  Status: Open,  Structure Length: 5.57m (18.27ft),  Average Daily Traffic: 14,900 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,000 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: TEN MILE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 138.384,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900181,  Location: PINECREST DR. (Lat: 40.643283,  Lng: -89.540497),  Route carried "on" structure: Other road ,  Year Built: 2021,  Status: Open,  Structure Length: 6.53m (21.42ft),  Average Daily Traffic: 5,100 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,214 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: I-74,  Facility Carried by Structure: PINECREST DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.543,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 0.0m,  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 23.1m (75.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 902001,  Location: SW-33-T26NR4W (Lat: 40.664650,  Lng: -89.577428),  Route carried "on" structure: Other road ,  Year Built: 1953,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 5,175 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,074 (year 2032),  Design Load: HS 20,  Features Intersected: COLE CREEK,  Facility Carried by Structure: WASHINGTON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.320,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 2.8m (9.2ft),  Right: 2.8m (9.2ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 18.8m (61.7ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 902006,  Location: .1M S JCT US 150&116 (Lat: 40.713342,  Lng: -89.530450),  Route carried "on" structure: US 24,  Year Built: 1964,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 20,400 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 26,660 (year 2032),  Design Load: HS 20,  Features Intersected: IL RIVER TRIBUTARY,  Facility Carried by Structure: US 150 & ILL 116
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 218.768,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 12 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Fair,  Culverts: Poor,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 902013,  Location: SW RAMP MCCLUGAGE (Lat: 40.713417,  Lng: -89.531219),  Route carried "on" structure: Other road ,  Year Built: 1993,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 3,700 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,031 (year 2032),  Design Load: HS 20,  Features Intersected: IL RIVER TRIB.,  Facility Carried by Structure: ILL 116 RP #2.64
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.467,  Lanes on structure: 1,  Base Highway Network: Yes (Inventory Route: 20673040,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2017
Find on map >>   Show street view

Structure Number: 902016,  Location: E OF CARVER LANE (Lat: 40.676950,  Lng: -89.531286),  Route carried "on" structure: State highway 8,  Year Built: 2003,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 14,700 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,448 (year 2032),  Design Load: HS 20,  Features Intersected: BRANCH FARM CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 61.781,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 902017,  Location: AT ARNOLD RD (Lat: 40.673617,  Lng: -89.543636),  Route carried "on" structure: State highway 8,  Year Built: 1999,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 20,200 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 22,360 (year 2032),  Design Load: HS 20,  Features Intersected: DOLANS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.671,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 82.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 903193,  Location: NE-35-T26NR4W (Lat: 40.673756,  Lng: -89.526331),  Route carried "on" structure: Other road ,  Year Built: 1985,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 3,550 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,999 (year 2032),  Design Load: HS 20,  Features Intersected: BR OF FARM CREEK,  Facility Carried by Structure: FARMDALE RD-FAU 67
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.141,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.6m (41.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 903225,  Location: N CTR-35-T26NR4W (Lat: 40.674950,  Lng: -89.531886),  Route carried "on" structure: Other road ,  Year Built: 1999,  Status: Open,  Structure Length: 0.84m (2.76ft),  Average Daily Traffic: 3,550 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,999 (year 2032),  Design Load: HS 20,  Features Intersected: BRANCH TO FARM CREEK,  Facility Carried by Structure: FAU 6775-FARMDALE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.640,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.6m (8.5ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 903234,  Location: E1/2-SEC36-T26NR4W (Lat: 40.667367,  Lng: -89.504736),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 725 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 806 (year 2032),  Design Load: HS 20,  Features Intersected: FARM CREEK,  Facility Carried by Structure: TR 23(FARMDALE RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.241,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 903244,  Location: SE-36-T26NR4W (Lat: 40.664711,  Lng: -89.508911),  Route carried "on" structure: County highway ,  Year Built: 2012,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 2,450 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,450 (year 2034),  Design Load: HS 25 or greater,  Features Intersected: Farm Creek,  Facility Carried by Structure: TR 156
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.225,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.2m (46.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 905023,  Location: NE-5-T25NR4W (Lat: 40.655378,  Lng: -89.575397),  Route carried "on" structure: Other road ,  Year Built: 1954,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,200 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,473 (year 2032),  Features Intersected: STREAM,  Facility Carried by Structure: FAU 6699
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.159,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Poor,  Culverts: Fair,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 906028,  Location: N1/2-5-T25NR4W (Lat: 40.663117,  Lng: -89.577019),  Route carried "on" structure: City street ,  Year Built: 1953,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 825 (year 2018),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,881 (year 2032),  Design Load: HS 15,  Features Intersected: COLE CR,  Facility Carried by Structure: STEWART ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.064,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.5m (24.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 906029,  Location: SE-34-T26NR4W (Lat: 40.661281,  Lng: -89.559475),  Route carried "on" structure: City street ,  Year Built: 1980,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 750 (year 2018),  Truck Traffic: 15%,  Average Future Daily Traffic: 1,183 (year 2032),  Design Load: HS 20,  Features Intersected: KERFOOT CREEK,  Facility Carried by Structure: KERFOOT STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 906031,  Location: E-29-T26NR4W (Lat: 40.667936,  Lng: -89.601081),  Route carried "on" structure: City street ,  Year Built: 1960,  Status: Open,  Structure Length: 0.80m (2.62ft),  Average Daily Traffic: 1,150 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 806 (year 2032),  Design Load: HS 15,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: SPENCER ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.193,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 906034,  Location: S1/2-34-T26NR4W (Lat: 40.663811,  Lng: -89.563200),  Route carried "on" structure: Other road ,  Year Built: 1981,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 5,150 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,665 (year 2032),  Design Load: HS 20,  Features Intersected: KERFOOT CR,  Facility Carried by Structure: VETERANS DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.370,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 62.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 906035,  Location: 0.10MI SE OF ILL 116 (Lat: 40.666786,  Lng: -89.577883),  Route carried "on" structure: Other road ,  Year Built: 1992,  Status: Open,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 2,700 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,494 (year 2032),  Design Load: HS 20,  Features Intersected: COLE CREEK,  Facility Carried by Structure: SPRINGFIELD RD-967
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.113,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.2m (36.7ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 906037,  Location: NE-4-T25NR4W (Lat: 40.660425,  Lng: -89.555461),  Route carried "on" structure: Other road ,  Year Built: 2006,  Status: Open,  Structure Length: 1.39m (4.56ft),  Average Daily Traffic: 625 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 806 (year 2032),  Design Load: HS 20,  Features Intersected: KERFOOT CREEK,  Facility Carried by Structure: FAHEY HOLLOW RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Serious,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 906086,  Location: 0.3 Mi. SE of Ill 40 (Lat: 40.673997,  Lng: -89.583131),  Route carried "on" structure: Other road ,  Year Built: 2012,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 5,050 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,015 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: FARM CREEK,  Facility Carried by Structure: Heritage St
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.290,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 4.6m (15.1ft),  Right: 0.0m,  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 22.4m (73.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 906087,  Location: SE-36-T26NR4W (Lat: 40.667900,  Lng: -89.520728),  Route carried "on" structure: Other road ,  Year Built: 2014,  Status: Open,  Structure Length: 3.12m (10.24ft),  Average Daily Traffic: 1,550 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,526 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: FARM CREEK,  Facility Carried by Structure: RIDGE RD- FAU6774
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.320,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 90609,  Location: 0.5 SW of Camp St (Lat: 40.670497,  Lng: -89.580525),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 6,600 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,386 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Farm Creek,  Facility Carried by Structure: Spinder-MS 2375
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.354,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 13.9m (45.6ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 900008,  Location: .5 MI E OF ILL 116 (Lat: 40.666269,  Lng: -89.570847),  Route carried "under" structure: US 150,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 18,600 (year 2021),  Truck Traffic: 3%,  Features Intersected: US 150,FARM CR&RRS,  Facility Carried by Structure: EB I-74
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 152.835,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.9m (153.9ft)

Find on map >>   Show street view

Structure Number: 900009,  Location: .5 MI E OF ILL 116 (Lat: 40.666186,  Lng: -89.569658),  Route carried "under" structure: US 150,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 18,600 (year 2021),  Truck Traffic: 3%,  Features Intersected: US150,FARM CR& RRS,  Facility Carried by Structure: WB I-74
Minimum Vertical Clearance: 6.53m (21.42ft),  Kilometerpoint: 152.948,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.9m (153.9ft)

Find on map >>   Show street view

Structure Number: 900031,  Location: CEDAR ST EXTENSION (Lat: 40.672156,  Lng: -89.593739),  Route carried "under" structure: City street ,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 2,150 (year 2018),  Truck Traffic: 2%,  Features Intersected: RICHLAND ST.,  Facility Carried by Structure: IL 8/ IL 116
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.097,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 900032,  Location: CEDAR ST EXTENSION (Lat: 40.669303,  Lng: -89.590656),  Route carried "under" structure: Other road ,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 4,300 (year 2018),  Truck Traffic: 3%,  Features Intersected: EDMUND ST,  Facility Carried by Structure: IL 8/ IL 116
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 0.016,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 900033,  Location: CEDAR ST EXTENSION (Lat: 40.667367,  Lng: -89.588069),  Route carried "under" structure: City street ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 1,350 (year 2018),  Truck Traffic: 15%,  Features Intersected: CENTER STREET,  Facility Carried by Structure: IL 8/ IL 116
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.402,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>   Show street view

Structure Number: 900035,  Location: CEDAR ST EXT E PEO (Lat: 40.663861,  Lng: -89.583750),  Route carried "under" structure: US 24,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 26,200 (year 2021),  Truck Traffic: 4%,  Features Intersected: US 24/ IL 29,  Facility Carried by Structure: IL 8/ IL 116
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 211.494,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 900037,  Location: MEADOWS AVE E. PEO. (Lat: 40.667539,  Lng: -89.560800),  Route carried "under" structure: Other road ,  Year Built: 1935,  Structure Length: 0. m,  Average Daily Traffic: 325 (year 2018),  Truck Traffic: 12%,  Features Intersected: FARM CR TPW NYC RR,  Facility Carried by Structure: US 150- MEADOWS AV
Minimum Vertical Clearance: 6.73m (22.08ft),  Kilometerpoint: 0.370,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.9m (167.0ft)

Discuss East Peoria, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.