- Critical: Backflow Prevention, Air Gap
- Comment:
- OBSERVED THAT A DRAINLINE HAS BEEN INSTALLED FOR THE ICE BIN TO AN INDIRECT WASTE WITH AN AIR GAP. CORRECTED.
- General violation description:
- 5-202.13 - An air gap between the water supply inlet and the flood level rim of the PLUMBING FIXTURE, EQUIPMENT, or nonFOOD EQUIPMENT shall be at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch).
- Floors, Walls, and Ceilings
- Comment:
- OBSERVED THAT THE FLOOR HAS BEEN REPAIRED PROVIDING A SMOOTH SURFACE UNDER THE FIXED EQUIPMENT AND THE ROUGH DIVOTS HAVE BEEN FILLED IN WITH A SMOOTH DURABLE MATERIAL. CORRECTED.
- General violation description:
- 6-201.11 - Except as specified under # 6-201.14 and except for antislip floor coverings or applications that may be used for safety reasons, floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are SMOOTH and EASILY CLEANABLE.
- Floors, Walls, and Ceilings, U
- Comment:
- OBSERVED THAT THE EXCESS ELECTRICAL CONDUIT HAS BEEN ELIMINATED PROVIDING ACCESS TO THE CEILING FOR CLEANING. CORRECTED.
- General violation description:
- 6-201.12 - (A) Utility service lines and pipes may not be unnecessarily exposed. (B) Exposed utility service lines and pipes shall be installed so they do not obstruct or prevent cleaning of the floors, walls, or ceilings. (C) Exposed horizontal utility service lines and pipes may not be installed on the floor.
- Nonfood-Contact Surfaces
- Comment:
- OBSERVED THAT THE CREVISES AND LARGE OPENINGS HAVE BEEN ELIMINATED
- General violation description:
- 4-202.16 - TRIM HAS BEEN INSTALLED UNDER THE LIP OF THE MOP SINK BACKSPLASH AND A CAP PLACED ON THE END OF THE OPEN CHASE BEHIND THE ICE MACHINE. AREAS ARE NOW SMOOTH AND EASILY CLEANABLE. CORRECTED.
|
05/26/2015 | Follow-up |
Restaurant representatives - add corrected or new information about Chipotle Mexican Grill #2420, 18885 Traditions Drive, Northville, MI 48168 »