Cold Holding Potentially Hazardous Foods (46.385(a)(2)-(a)(5))
Various foods in the True refrigerator and open-faced self-service refrigerator in the cafeteria were held above rather than 41 degrees F or below as required. Temperature of True refrigerator was lowered during inspection. Items in the open-faced self-service unit are discarded within 4 hours.
10/04/2010
Regular
Water Temperature & Pressure when Hot Water is Used for Sanitizing in Mechanical Warewashing (46.675(d)(e))
The food-contact surfaces of equipment and utensils did not reach 160 degrees F during the sanitizing cycle of the high temperature dishwasher as evidenced by the failure of the temperature indicator. High-temp auto warewasher was not reaching 160 degrees F at the beginning of the inspection. It was, however, repaired by the end of the inspection.
Objective of Cleaning Grease & Soil Accumulations & Nonfood Contact Surfaces (46.711(b)(c))
Sides of cooking equipment and shelves in need of cleaning.
Maintaining & Using a Handwashing Facility (46.825(a) & 46.981(h))
The hot water at the handsink at the coffee kiosk (on the first floor) does not stay on. Employee would have to hold the faucet in the 'on' position for it to continuously run. Hot and cold water should be continuously running at this handsink.
Plumbing Facilities in Good Repair, Cross Connection Prohibited, Scheduled Inspections, Cleaning Water Reservoirs (46.825(b)-(e))
Leak observed at drain line of three-basin sink and at pipes of kettle cookers (insulation in need of replacing).
Cleaning Ventilation Systems (46.981(d))
Hood filters have an accumulation of static dust and grease. Mesh covering above three-basin sink in need of cleaning.
08/04/2010
Regular
Identification of Content on Food Storage Containers (46.282)
Working bulk food ingredient storage containers are not labeled with the common name of the food.
Equipment in Good Repair & Proper Adjustment (46.671)
Broken garbage grinder in prep area that is scheduled to be removed. ***Note: A working garbage grinder is present in dishroom.***
Light Bulb Protective Shielding (46.922(a))
Provide end caps on protective light shields where lacking.
Repair & Cleaning Various Premises, Structures, Attachments & Fixtures (46.981(a)-(c)(g)(n))
-Replace pipe insulation in soup prep area. -Regrout floor in dishroom, where needed.