  • National Bridge Inventory (NBI) Statistics
  • 327Number of bridges
  • 5,604ft / 1,708mTotal length
  • $142,880,000Total costs
  • 8,556,472Total average daily traffic
  • 1,227,785Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Stockton
  • No street view available for this location

New bridges in Stockton, CA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 51920-1929
  • 151930-1939
  • 81940-1949
  • 251950-1959
  • 531960-1969
  • 1401970-1979
  • 131980-1989
  • 201990-1999
  • 192000-2009
  • 282010-2019
Reconstructed bridges in Stockton, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21940-1949
  • 01950-1959
  • 61960-1969
  • 41970-1979
  • 31980-1989
  • 81990-1999
  • 92000-2009
  • 152010-2019
Average Bridge Daily Traffic in Stockton, CA
Average Bridge Truck Traffic in Stockton, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 40.6%Good
  • 9.9%Satisfactory
  • 36.6%Fair
  • 12.9%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 58.1%Good
  • 5.9%Satisfactory
  • 26.1%Fair
  • 9.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 78.8%Good
  • 4.4%Satisfactory
  • 16.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.9%Excellent
  • 22.8%Very good
  • 42.1%Good
  • 20.7%Satisfactory
  • 5.5%Fair
  • 1.4%Poor
  • 0.7%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 4.0%Very good
  • 44.0%Good
  • 48.0%Satisfactory
  • 4.0%Poor
Find on map >>   Show street view

Structure Number: 29 0238S,  Location: 10-SJ-004-R16.20-STKN (Lat: 37.948358,  Lng: -121.297922),  Route carried "on" structure: Ramp State highway 4,  Year Built: 1972,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 4,700 (year 2000),  Truck Traffic: 10%,  Average Future Daily Traffic: 7,615 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MORMON SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.200,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Underwater Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0239F,  Location: 10-SJ-004-R16.48-STKN (Lat: 37.949803,  Lng: -121.293342),  Route carried "on" structure: Ramp State highway 4,  Year Built: 1972,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 15,500 (year 2009),  Truck Traffic: 14%,  Average Future Daily Traffic: 16,630 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MADISON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.480,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 23.1m (75.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0239H,  Location: 10-SJ-005-26.11-STKN (Lat: 37.949044,  Lng: -121.293142),  Route carried "on" structure: Ramp Interstate 5,  Year Built: 1972,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 31,200 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 39,678 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MADISON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.110,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 22.2m (72.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.1m (144.7ft),  Curb-To-Curb Width: 22.2m (72.8ft),  Out-to-Out Width: 24.8m (81.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0239L,  Location: 10-SJ-004-R16.47-STKN (Lat: 37.949606,  Lng: -121.293328),  Route carried "on" structure: State highway 4,  Year Built: 1972,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 15,500 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 38,636 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MADISON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.470,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.3m (53.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0239R,  Location: 10-SJ-004-R16.47-STKN (Lat: 37.949358,  Lng: -121.293228),  Route carried "on" structure: State highway 4,  Year Built: 1972,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 15,500 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 38,636 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MADISON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.470,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0240L,  Location: 10-SJ-004-R15.67-STKN (Lat: 37.946228,  Lng: -121.307158),  Route carried "on" structure: State highway 4,  Year Built: 1972,  Status: Open,  Structure Length: 5.91m (19.39ft),  Average Daily Traffic: 13,250 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,690 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPBR & GARFIELD AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.670,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 22.9m (75.1ft),  Out-to-Out Width: 23.6m (77.4ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 85.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0240R,  Location: 10-SJ-004-R15.67-STKN (Lat: 37.945844,  Lng: -121.307053),  Route carried "on" structure: State highway 4,  Year Built: 1972,  Status: Open,  Structure Length: 5.91m (19.39ft),  Average Daily Traffic: 13,250 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,690 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SPBR & GARFIELD AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.670,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 26.8m (87.9ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 60.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0260L,  Location: 10-SJ-005-6.41 (Lat: 37.681061,  Lng: -121.343381),  Route carried "on" structure: Interstate 5,  Year Built: 1971,  Status: Open,  Structure Length: 11.40m (37.40ft),  Average Daily Traffic: 11,400 (year 2016),  Truck Traffic: 25%,  Average Future Daily Traffic: 22,365 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: CFNR & STATE ROUTE 33
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.410,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 57.0m (187.0ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0269,  Location: 10-SJ-004-R16.62-STKN (Lat: 37.949703,  Lng: -121.290542),  Route carried "on" structure: State highway 4,  Year Built: 1975,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 133.11m (436.71ft),  Average Daily Traffic: 74,000 (year 2009),  Truck Traffic: 10%,  Average Future Daily Traffic: 114,198 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: CROSSTOWN FWY VIADUCT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.620,  Lanes on structure: 6,  Lanes under structure: 23,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 37.9m (124.3ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 36,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 30.6m (100.4ft),  Out-to-Out Width: 33.1m (108.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0300L,  Location: 10-SJ-004-R17.56-STKN (Lat: 37.952894,  Lng: -121.273911),  Route carried "on" structure: State highway 4,  Year Built: 1988,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 44,500 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 68,846 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: AIRPORT WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.560,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.9m (157.2ft),  Curb-To-Curb Width: 20.4m (66.9ft),  Out-to-Out Width: 22.2m (72.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0300R,  Location: 10-SJ-004-R17.56-STKN (Lat: 37.952569,  Lng: -121.273822),  Route carried "on" structure: State highway 4,  Year Built: 1988,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 44,500 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 68,846 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: AIRPORT WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.560,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.9m (157.2ft),  Curb-To-Curb Width: 15.3m (50.2ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0303,  Location: 10-SJ-004-R18.06-STKN (Lat: 37.955456,  Lng: -121.265933),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 12,000 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 16,138 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: SR 4,  Facility Carried by Structure: MAIN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 44.9m (147.3ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 25.0m (82.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0304,  Location: 10-SJ-004-R18.52-STKN (Lat: 37.958772,  Lng: -121.258328),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 2,200 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,240 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: SR 4,  Facility Carried by Structure: E ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0305,  Location: 10-SJ-004-R18.77-STKN (Lat: 37.959878,  Lng: -121.253894),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 5.52m (18.11ft),  Average Daily Traffic: 16,500 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 23,128 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: SR 4,  Facility Carried by Structure: FILBERT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.7m (94.2ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 28.7m (94.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0306L,  Location: 10-SJ-004-R17.71-STKN (Lat: 37.953347,  Lng: -121.271147),  Route carried "on" structure: State highway 4,  Year Built: 1992,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 45,500 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 68,846 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: WILSON WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.710,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 48.0m (157.5ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0306R,  Location: 10-SJ-004-R17.71-STKN (Lat: 37.953111,  Lng: -121.271089),  Route carried "on" structure: State highway 4,  Year Built: 1992,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 45,500 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 68,846 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: WILSON WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.710,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 48.0m (157.5ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0308,  Location: 10-SJ-099-18.89 (Lat: 37.964136,  Lng: -121.243492),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 9.55m (31.33ft),  Average Daily Traffic: 500 (year 1998),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,631 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 99 & RAMPS,  Facility Carried by Structure: MYRTLE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 51.8m (169.9ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0316,  Location: 10-SJ-099-14.61-STKN (Lat: 37.904283,  Lng: -121.222411),  Route carried "on" structure: State highway 99,  Year Built: 2006,  Status: Open,  Structure Length: 14.30m (46.92ft),  Average Daily Traffic: 70,500 (year 2009),  Truck Traffic: 20%,  Average Future Daily Traffic: 91,368 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ARCH ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.610,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 34.9m (114.5ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 70.0m (229.7ft),  Curb-To-Curb Width: 34.9m (114.5ft),  Out-to-Out Width: 36.0m (118.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 032,  Location: 10-SJ-099-2.34-RIP (Lat: 37.752364,  Lng: -121.141967),  Route carried "on" structure: Business County highway W813,  Year Built: 2001,  Status: Open,  Structure Length: 9.32m (30.58ft),  Average Daily Traffic: 20,000 (year 2009),  Truck Traffic: 30%,  Average Future Daily Traffic: 32,821 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: JACK TONE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 48.7m (159.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0324,  Location: 10-SJ-099-22.92 (Lat: 38.021025,  Lng: -121.258692),  Route carried "on" structure: City street ,  Year Built: 2007,  Status: Open,  Structure Length: 8.76m (28.74ft),  Average Daily Traffic: 18,000 (year 1999),  Truck Traffic: 5%,  Average Future Daily Traffic: 26,845 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: HAMMER LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 33.0m (108.3ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 45.5m (149.3ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 33.0m (108.3ft),  Out-to-Out Width: 36.5m (119.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 93.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 56.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 29 0325,  Location: 10-SJ-099-16.68-STKN (Lat: 37.933822,  Lng: -121.234450),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 9.37m (30.74ft),  Average Daily Traffic: 9,400 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 20,471 (year 2042),  Design Load: HL 93,  Features Intersected: SR 99,  Facility Carried by Structure: MARIPOSA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 47.5m (155.8ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 32.0m (105.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0327,  Location: 10-SJ-099-18.15-STKN (Lat: 37.954222,  Lng: -121.239492),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 20,000 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 24,566 (year 2040),  Design Load: HL 93,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: MAIN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0329,  Location: 10-SJ-099-18.02-STKN (Lat: 37.952453,  Lng: -121.238958),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 8.05m (26.41ft),  Average Daily Traffic: 11,700 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 20,471 (year 2042),  Design Load: HL 93,  Features Intersected: HWY 99,  Facility Carried by Structure: DR MLK JR BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 41.9m (137.5ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0334,  Location: 10-SJ-099-16.46-STKN (Lat: 37.930861,  Lng: -121.232831),  Route carried "on" structure: Ramp State highway 99,  Year Built: 2016,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 5,000 (year 2016),  Truck Traffic: 13%,  Average Future Daily Traffic: 10,202 (year 2042),  Design Load: HL 93,  Features Intersected: DUCK CREEK SOUTH BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.460,  Lanes on structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0335,  Location: 10-SJ-099-16.48-STKN (Lat: 37.931067,  Lng: -121.232867),  Route carried "on" structure: Ramp State highway 99,  Year Built: 2016,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 5,000 (year 2016),  Truck Traffic: 13%,  Average Future Daily Traffic: 10,202 (year 2042),  Design Load: HL 93,  Features Intersected: DUCK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.480,  Lanes on structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 14.7m (48.2ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 035,  Location: 10-SJ-004-R15.70-STKN (Lat: 37.938800,  Lng: -121.320064),  Route carried "on" structure: State highway 4,  Year Built: 2017,  Status: Open,  Structure Length: 87.49m (287.04ft),  Average Daily Traffic: 15,800 (year 2009),  Truck Traffic: 11%,  Average Future Daily Traffic: 24,457 (year 2043),  Design Load: HL 93,  Features Intersected: STATE ROUTE 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.700,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 21,  Length of Maximum Span: 50.3m (165.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 29C0051,  Location: S/E OF S.H. 26 (Lat: 38.049289,  Lng: -121.014128),  Route carried "on" structure: County highway ,  Year Built: 1966,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 2,430 (year 2013),  Truck Traffic: 25%,  Average Future Daily Traffic: 1,363 (year 2041),  Design Load: HS 20,  Features Intersected: MORMON SLOUGH,  Facility Carried by Structure: ESCALON BELLOTA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Serious,  Operating Rating: 52.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.80m (22.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $843,000,  Roadway Improvement Cost: $168,000,  Total Project Cost: $1,416,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0052,  Location: S DAVIS RD IN TX (Lat: 38.028222,  Lng: -121.331492),  Route carried "on" structure: County highway ,  Year Built: 1931,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 26,616 (year 2013),  Truck Traffic: 2%,  Average Future Daily Traffic: 25,607 (year 2042),  Features Intersected: MOSHER SLOUGH,  Facility Carried by Structure: THORNTON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.3m (17.4ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 32.5m (106.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 26.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0058L,  Location: 0.25 MI N FULTON ST (Lat: 37.983725,  Lng: -121.309611),  Route carried "on" structure: City street ,  Year Built: 1921,  Year Reconstructed: 1951,  Status: Open,  Structure Length: 7.71m (25.30ft),  Average Daily Traffic: 18,350 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 23,863 (year 2042),  Features Intersected: CALAVERAS RIVER,  Facility Carried by Structure: PACIFIC AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 2.8m (9.2ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Poor,  Operating Rating: 23.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0058R,  Location: 0.25 MI N FULTON ST (Lat: 37.983856,  Lng: -121.309436),  Route carried "on" structure: City street ,  Year Built: 1952,  Status: Open,  Structure Length: 7.80m (25.59ft),  Average Daily Traffic: 18,350 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 23,863 (year 2042),  Design Load: H 20,  Features Intersected: CALAVERAS RIVER,  Facility Carried by Structure: PACIFIC AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 6.4m (21.0ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0061,  Location: 0.1 MI S JAHANT RD (Lat: 38.204828,  Lng: -121.092653),  Route carried "on" structure: County highway ,  Year Built: 1976,  Status: Open,  Structure Length: 11.06m (36.29ft),  Average Daily Traffic: 1,202 (year 2016),  Truck Traffic: 15%,  Average Future Daily Traffic: 858 (year 2039),  Design Load: HS 20,  Features Intersected: MOKELUMNE RIVER,  Facility Carried by Structure: MACKVILLE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.6m (120.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 48.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2022,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0066,  Location: 0.8 MI S OF 8 MILE ROAD (Lat: 38.042758,  Lng: -121.258983),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 2,000 (year 2015),  Truck Traffic: 18%,  Average Future Daily Traffic: 3,000 (year 2038),  Design Load: HS 20,  Features Intersected: MOSHER SLOUGH,  Facility Carried by Structure: 99 FRONTAGE RD W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0068,  Location: 0.4 MI N OF 8 MILE RD (Lat: 38.060247,  Lng: -121.259864),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 5.04m (16.54ft),  Average Daily Traffic: 3,737 (year 2015),  Truck Traffic: 15%,  Average Future Daily Traffic: 8,008 (year 2038),  Design Load: HS 20,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: 99 FRONTAGE RD W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0074,  Location: 1.2 MI N MARIPOSA RD (Lat: 37.921275,  Lng: -121.147542),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 3,202 (year 2013),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,254 (year 2043),  Design Load: HS 20,  Features Intersected: NORTH LITTLE JOHNS CREEK,  Facility Carried by Structure: JACK TONE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C008,  Location: 1 MI N LIVE OAK RD (Lat: 38.094094,  Lng: -121.150756),  Route carried "on" structure: County highway ,  Year Built: 1962,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 2,715 (year 2013),  Truck Traffic: 30%,  Average Future Daily Traffic: 2,137 (year 2038),  Design Load: HS 20,  Features Intersected: PADDY CREEK SOUTH,  Facility Carried by Structure: JACK TONE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0086,  Location: 0.5 MI N HAMMER LANE (Lat: 38.028053,  Lng: -121.294800),  Route carried "on" structure: City street ,  Year Built: 1966,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 27,300 (year 2007),  Truck Traffic: 16%,  Average Future Daily Traffic: 23,280 (year 2038),  Design Load: H 20,  Features Intersected: MOSHER SLOUGH,  Facility Carried by Structure: WEST LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 25.9m (85.0ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 21.4m (70.2ft),  Out-to-Out Width: 29.3m (96.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0087,  Location: 1/2 MI N/W OF S.H. 99 (Lat: 37.948439,  Lng: -121.241836),  Route carried "on" structure: County highway ,  Year Built: 1966,  Year Reconstructed: 2015,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 2,469 (year 2017),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,600 (year 2039),  Design Load: HS 20,  Features Intersected: MORMON SLOUGH,  Facility Carried by Structure: GOLDEN GATE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.6m (57.7ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 60.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0088,  Location: 0.3 MI W LINCOLN ST (Lat: 37.951467,  Lng: -121.303667),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 6,100 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,321 (year 2038),  Design Load: HS 20,  Features Intersected: MORMON SLOUGH,  Facility Carried by Structure: WEBER ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 28.7m (94.2ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 4.0m (13.1ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 28.7m (94.2ft),  Out-to-Out Width: 33.5m (109.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2021,  Underwater Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C009,  Location: 17.52 MI N STNLAUS CO LI (Lat: 37.880803,  Lng: -121.249019),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 6.46m (21.19ft),  Average Daily Traffic: 12,716 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,456 (year 2039),  Design Load: HS 20,  Features Intersected: FRENCH CAMP SLOUGH,  Facility Carried by Structure: AIRPORT WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 25.9m (85.0ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 28.7m (94.2ft),  Out-to-Out Width: 28.9m (94.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Stockton, California (CA) on our hugely popular California forum.