Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Stockton, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 327Number of bridges
  • 5,604ft / 1,708mTotal length
  • $142,880,000Total costs
  • 8,556,472Total average daily traffic
  • 1,227,785Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Stockton
  • No street view available for this location

New bridges in Stockton, CA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 51920-1929
  • 151930-1939
  • 81940-1949
  • 251950-1959
  • 531960-1969
  • 1401970-1979
  • 131980-1989
  • 201990-1999
  • 192000-2009
  • 282010-2019
Reconstructed bridges in Stockton, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21940-1949
  • 01950-1959
  • 61960-1969
  • 41970-1979
  • 31980-1989
  • 81990-1999
  • 92000-2009
  • 152010-2019
Average Bridge Daily Traffic in Stockton, CA
Average Bridge Truck Traffic in Stockton, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 40.6%Good
  • 9.9%Satisfactory
  • 36.6%Fair
  • 12.9%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 58.1%Good
  • 5.9%Satisfactory
  • 26.1%Fair
  • 9.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 78.8%Good
  • 4.4%Satisfactory
  • 16.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.9%Excellent
  • 22.8%Very good
  • 42.1%Good
  • 20.7%Satisfactory
  • 5.5%Fair
  • 1.4%Poor
  • 0.7%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 4.0%Very good
  • 44.0%Good
  • 48.0%Satisfactory
  • 4.0%Poor
Find on map >>   Show street view

Structure Number: 29C0401,  Location: 1.0 MI N OF MARCH LANE (Lat: 37.996117,  Lng: -121.349675),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 11.09m (36.38ft),  Average Daily Traffic: 8,300 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,512 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: FOURTEEN MILE SLOUGH,  Facility Carried by Structure: FEATHER RIVER DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 2 degrees,  Navigation Control: Yes ( Vertical Clearance: 4.6m (15.1ft), Horizontal Clearance: 9.1m (29.9ft)),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 11.09m (36.38ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $1,754,000,  Roadway Improvement Cost: $350,000,  Total Project Cost: $2,946,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0402,  Location: 0.1 KM W OF RTE 5 (Lat: 38.032386,  Lng: -121.364744),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 3,300 (year 2003),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,274 (year 2043),  Design Load: HS 20,  Features Intersected: MOSHER SLOUGH,  Facility Carried by Structure: MARINERS DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0407,  Location: 0.7 MI WEST OF MANTHEY RD (Lat: 37.912644,  Lng: -121.292514),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 10.73m (35.20ft),  Average Daily Traffic: 16,700 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 20,041 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: FRENCH CAMP SLOUGH,  Facility Carried by Structure: CAROLYN WESTON BLV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 33 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 45.1m (148.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.7m (77.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Channel: Excellent,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 10.73m (35.20ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2021,  Underwater Inspection Date: September 2019,  Bridge Improvement Cost: $6,420,000,  Roadway Improvement Cost: $513,000,  Total Project Cost: $6,933,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0411,  Location: 0.4 MI N/O E VERDON RD (Lat: 37.889228,  Lng: -121.146606),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 21.73m (71.29ft),  Average Daily Traffic: 3,684 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,324 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: N FK S LITTLEJOHNS CREEK,  Facility Carried by Structure: JACK TONE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 42.4m (139.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0412,  Location: W OF RTE 99, S OF AIRPORT (Lat: 37.897317,  Lng: -121.220892),  Route carried "on" structure: Business County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 4,000 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,275 (year 2038),  Features Intersected: WEBER CREEK S BRANCH,  Facility Carried by Structure: QUANTAS LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.5m (21.3ft),  Skew: 6 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 29C0414,  Location: 1 MILE WEST OF KAISER RD (Lat: 37.911750,  Lng: -121.184317),  Route carried "on" structure: Business County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 21.43m (70.31ft),  Average Daily Traffic: 6,397 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,871 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: AUSTIN ROAD & BNSF RY,  Facility Carried by Structure: MARIPOSA ROAD OH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0417,  Location: 0.2 MI WEST OF AIRPORT WY (Lat: 37.940928,  Lng: -121.274000),  Route carried "on" structure: ServiceCity street ,  Year Built: 1937,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 150 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 350 (year 2039),  Features Intersected: MARTIN LUTHER KING JR BL,  Facility Carried by Structure: UP RR, BNSF RY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 45.5m (149.3ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 47.0m (154.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 25.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 15.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0418,  Location: 0.1 MI W N AIRPORT WAY (Lat: 37.941117,  Lng: -121.272911),  Route carried "on" structure: City street ,  Year Built: 1937,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 30 (year 2017),  Truck Traffic: 1%,  Average Future Daily Traffic: 40 (year 2038),  Features Intersected: MARTIN LUTHER KING JR BL,  Facility Carried by Structure: UP RR, BNSF,AMTRAK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 24.5m (80.4ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.0m (29.5ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 27.4m (89.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 35.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.98m (6.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $1,248,000,  Roadway Improvement Cost: $249,000,  Total Project Cost: $2,098,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0419,  Location: N OF MORADA LANE (Lat: 38.039514,  Lng: -121.269525),  Route carried "on" structure: Business City street ,  Year Built: 2006,  Status: Open,  Structure Length: 1.42m (4.66ft),  Average Daily Traffic: 8,000 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,582 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: MOSHER SLOUGH,  Facility Carried by Structure: HOLMAN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 34.7m (113.8ft),  Skew: 31 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 29.3m (96.1ft),  Out-to-Out Width: 38.7m (127.0ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.42m (4.66ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $550,000,  Roadway Improvement Cost: $110,000,  Total Project Cost: $924,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0424,  Location: 1 MILE W OF ROUTE 99 (Lat: 38.036864,  Lng: -121.276836),  Route carried "on" structure: Alternate City street ,  Year Built: 2007,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 13,800 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,164 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: MOSHER SLOUGH,  Facility Carried by Structure: MORADA LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 31.4m (103.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0425,  Location: N OF INDUSTRIAL DRIVE (Lat: 37.914272,  Lng: -121.238739),  Route carried "on" structure: Business City street ,  Year Built: 1993,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,500 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,294 (year 2043),  Features Intersected: NORTH LITTLE JOHNS CREEK,  Facility Carried by Structure: POCK LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 29C0426,  Location: JUST E OF POCK LANE (Lat: 37.914169,  Lng: -121.237339),  Route carried "on" structure: Business City street ,  Year Built: 1996,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 200 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 659 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: NORTH LITTLE JOHNS CREEK,  Facility Carried by Structure: INDUSTRIAL DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 6 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.0m (32.8ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 29C0427,  Location: SOUTH OF W EIGHT MILE RD (Lat: 38.054517,  Lng: -121.337228),  Route carried "on" structure: Business City street ,  Year Built: 2008,  Status: Open,  Structure Length: 2.82m (9.25ft),  Average Daily Traffic: 1,000 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,270 (year 2038),  Design Load: HS 20,  Features Intersected: PIXLEY SLOUGH,  Facility Carried by Structure: RIVERMONT DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Excellent,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0428,  Location: EAST OF THORNTON ROAD (Lat: 38.048089,  Lng: -121.342069),  Route carried "on" structure: Business City street ,  Year Built: 1991,  Status: Open,  Structure Length: 2.63m (8.63ft),  Average Daily Traffic: 1,597 (year 2003),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,078 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: PIXLEY SLOUGH,  Facility Carried by Structure: WHISTLER WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C043,  Location: 0.5 MI S OF WOODBRIDGE RD (Lat: 38.152158,  Lng: -121.301169),  Route carried "on" structure: Alternate County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 0.95m (3.12ft),  Average Daily Traffic: 9,116 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,575 (year 2044),  Design Load: HS 20+Mod,  Features Intersected: WOODBRIDGE ID MAIN CANAL,  Facility Carried by Structure: LOWERSACRAMENTO RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0431,  Location: 0.3 MI EAST OF MARIPOSA (Lat: 37.946861,  Lng: -121.250331),  Route carried "on" structure: City street ,  Year Built: 1949,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 3.60m (11.81ft),  Average Daily Traffic: 12,500 (year 2017),  Truck Traffic: 25%,  Average Future Daily Traffic: 20,026 (year 2038),  Design Load: HS 20,  Features Intersected: MORMON SLOUGH,  Facility Carried by Structure: DR MLK JR BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 35.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 29C0434,  Location: EAST OF I-5 PM 33.5 (Lat: 38.032467,  Lng: -121.363131),  Route carried "on" structure: Business City street ,  Year Built: 1980,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 9,100 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,926 (year 2038),  Features Intersected: MOSHER SLOUGH,  Facility Carried by Structure: KELLEY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.1m (26.6ft)

Condition: Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 29C0435,  Location: NEAR INDUSTRIAL DRIVE (Lat: 37.908403,  Lng: -121.269031),  Route carried "on" structure: Business City street ,  Year Built: 1982,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 5,000 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,557 (year 2043),  Design Load: HS 20,  Features Intersected: NORTH LITTLE JOHNS CREEK,  Facility Carried by Structure: PRODUCERS DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.7m (28.5ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.0m,  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Channel: Excellent,  Culverts: Poor,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.77m (5.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $299,000,  Roadway Improvement Cost: $59,000,  Total Project Cost: $502,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0436,  Location: S OF W EIGHT MILE ROAD (Lat: 38.043053,  Lng: -121.370522),  Route carried "on" structure: Business City street ,  Year Built: 2008,  Status: Open,  Structure Length: 5.85m (19.19ft),  Average Daily Traffic: 6 (year 2015),  Truck Traffic: 3%,  Average Future Daily Traffic: 10 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: BEAR CREEK,  Facility Carried by Structure: TRINITY PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.0m (65.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 0.0m,  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 29C0437,  Location: S OF 8 MI RD, E OF RR TRK (Lat: 38.057289,  Lng: -121.317639),  Route carried "on" structure: Business City street ,  Year Built: 2007,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 2,000 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,229 (year 2042),  Design Load: HS 20,  Features Intersected: PIXLEY SLOUGH,  Facility Carried by Structure: MARLETTE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.4m (27.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.2m (59.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C044,  Location: SOUTH OF WEST 8 MILE ROAD (Lat: 38.056133,  Lng: -121.333119),  Route carried "on" structure: Business City street ,  Year Built: 2011,  Status: Open,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 8,200 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,531 (year 2042),  Design Load: HL 93,  Features Intersected: PIXLEY SLOUGH,  Facility Carried by Structure: DAVIS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 4.6m (15.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0444,  Location: EAST OF LOWER SAC. ROAD (Lat: 38.057403,  Lng: -121.277511),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 7.41m (24.31ft),  Average Daily Traffic: 15,100 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 18,424 (year 2040),  Design Load: HL 93,  Features Intersected: UP RAILROAD TRACKS,  Facility Carried by Structure: EIGHT MILE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 29.9m (98.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.1m (115.2ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 29.9m (98.1ft),  Out-to-Out Width: 38.3m (125.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0445,  Location: WEST OF LOWER SAC. ROAD (Lat: 38.057917,  Lng: -121.325936),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 7.47m (24.51ft),  Average Daily Traffic: 15,100 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 18,424 (year 2042),  Design Load: HL 93,  Features Intersected: UP RAILROAD TRACKS,  Facility Carried by Structure: EIGHT MILE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 29.9m (98.1ft),  Skew: 32 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.4m (116.1ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 29.9m (98.1ft),  Out-to-Out Width: 38.3m (125.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C045,  Location: 1 MILE SOUTH OF ROUTE 12 (Lat: 38.152975,  Lng: -121.138397),  Route carried "on" structure: Business County highway ,  Year Built: 2011,  Status: Open,  Structure Length: 3.42m (11.22ft),  Average Daily Traffic: 1,055 (year 2013),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,200 (year 2039),  Features Intersected: BEAR CREEK,  Facility Carried by Structure: NORTH TULLY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0451,  Location: 0.25 MI S/E OF SR 99 (Lat: 37.932467,  Lng: -121.230489),  Route carried "on" structure: Business Other road ,  Year Built: 2016,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 4,642 (year 2013),  Truck Traffic: 40%,  Average Future Daily Traffic: 9,847 (year 2042),  Design Load: HL 93,  Features Intersected: DUCK CREEK,  Facility Carried by Structure: MARIPOSA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 32.2m (105.6ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 28.2m (92.5ft),  Out-to-Out Width: 32.2m (105.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0452,  Location: 0.34 MI EAST OF ROUTE 5 (Lat: 37.895472,  Lng: -121.277956),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 20,818 (year 2015),  Truck Traffic: 18%,  Average Future Daily Traffic: 30,605 (year 2038),  Design Load: HL 93,  Features Intersected: FRENCH CAMP SLOUGH,  Facility Carried by Structure: ARCH AIRPORT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 33.3m (109.3ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 46.9m (153.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 4.1m (13.5ft),  Curb-To-Curb Width: 33.3m (109.3ft),  Out-to-Out Width: 41.0m (134.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0453,  Location: 0.46 MI EAST OF ROUTE 5 (Lat: 37.895306,  Lng: -121.275833),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 11.51m (37.76ft),  Average Daily Traffic: 20,818 (year 2015),  Truck Traffic: 18%,  Average Future Daily Traffic: 30,605 (year 2038),  Design Load: HL 93,  Features Intersected: EL DORADO STREET,  Facility Carried by Structure: ARCH AIRPORT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.5m (106.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 4.1m (13.5ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0454,  Location: 0.56 MI EAST OF ROUTE 5 (Lat: 37.895894,  Lng: -121.274364),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 13.14m (43.11ft),  Average Daily Traffic: 20,818 (year 2015),  Truck Traffic: 18%,  Average Future Daily Traffic: 30,605 (year 2038),  Design Load: HL 93,  Features Intersected: UP RAILROAD TRACKS,  Facility Carried by Structure: ARCH AIRPORT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 52.7m (172.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 4.1m (13.5ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0455,  Location: 0.81 MI EAST OF ROUTE 5 (Lat: 37.897417,  Lng: -121.270147),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 12.66m (41.54ft),  Average Daily Traffic: 20,818 (year 2015),  Truck Traffic: 18%,  Average Future Daily Traffic: 30,605 (year 2038),  Design Load: HL 93,  Features Intersected: MCKINLEY, UPRR, PANATONI,  Facility Carried by Structure: ARCH AIRPORT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 56.8m (186.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 4.1m (13.5ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0456,  Location: 0.97 MI EAST OF ROUTE 5 (Lat: 37.898256,  Lng: -121.267475),  Route carried "on" structure: City street ,  Year Built: 2013,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 20,818 (year 2015),  Truck Traffic: 18%,  Average Future Daily Traffic: 30,605 (year 2038),  Design Load: HL 93,  Features Intersected: UP RAILROAD TRACKS,  Facility Carried by Structure: ARCH AIRPORT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 4.1m (13.5ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29C0464,  Location: ROUGH AND READY ISLAND (Lat: 37.946556,  Lng: -121.338517),  Route carried "on" structure: City street ,  Year Built: 2018,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 8,000 (year 2018),  Truck Traffic: 15%,  Average Future Daily Traffic: 12,000 (year 2040),  Design Load: HL 93,  Features Intersected: SAN JOAQUIN RIVER,  Facility Carried by Structure: NAVY DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: Local Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Navigation Control: Yes ( Vertical Clearance: 5.2m (17.1ft), Horizontal Clearance: 24.3m (79.7ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 31.6m (103.7ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.4m (66.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2020,  Underwater Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 29 0095,  Location: 10-SJ-099-21.91 (Lat: 38.006442,  Lng: -121.258375),  Route carried "under" structure: State highway 99,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 64,000 (year 2009),  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: FRONTAGE ROAD
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 21.910,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 29 0097,  Location: 10-SJ-099-24.03 (Lat: 38.037208,  Lng: -121.258856),  Route carried "under" structure: State highway 99,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 64,000 (year 2009),  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: MORADA LANE
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 24.030,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 29 01,  Location: 10-SJ-099-25.42 (Lat: 38.057364,  Lng: -121.259939),  Route carried "under" structure: State highway 99,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 64,000 (year 2009),  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: EIGHT MILE RD
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 25.420,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.2m (79.4ft)

Find on map >>   Show street view

Structure Number: 29 0118C,  Location: 10-SJ-099-21.67 (Lat: 38.002842,  Lng: -121.257661),  Route carried "under" structure: State highway 99,  Year Built: 1949,  Structure Length: 0. m,  Average Daily Traffic: 44,000 (year 2000),  Truck Traffic: 18%,  Features Intersected: STATE ROUTE 99 SB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 21.670,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 29 0122,  Location: 10-SJ-099-21.56 (Lat: 38.001464,  Lng: -121.256672),  Route carried "under" structure: State highway 99,  Year Built: 1949,  Structure Length: 0. m,  Average Daily Traffic: 71,000 (year 2009),  Truck Traffic: 13%,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: CCT RR
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 21.560,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 16.5m (54.1ft)

Find on map >>   Show street view

Structure Number: 29 0155,  Location: 10-SJ-004-19.75 (Lat: 37.941117,  Lng: -121.235278),  Route carried "under" structure: State highway 99,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 87,000 (year 2009),  Truck Traffic: 13%,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: FARMINGTON ROAD
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 17.190,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.0m (72.2ft)

Find on map >>   Show street view

Structure Number: 29 0173L,  Location: 10-SJ-005-28.26-STKN (Lat: 37.960486,  Lng: -121.333717),  Route carried "under" structure: City street ,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 2,500 (year 2009),  Truck Traffic: 10%,  Features Intersected: SHIMIZU DR & SMITH CANAL,  Facility Carried by Structure: INTERSTATE 5 SB
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 29 0173R,  Location: 10-SJ-005-28.26-STKN (Lat: 37.960567,  Lng: -121.333389),  Route carried "under" structure: City street ,  Year Built: 1968,  Structure Length: 0. m,  Average Daily Traffic: 2,500 (year 2009),  Truck Traffic: 10%,  Features Intersected: SHIMIZU DR & SMITH CANAL,  Facility Carried by Structure: INTERSTATE 5 NB
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 29 0188L,  Location: 10-SJ-005-27.91-STKN (Lat: 37.957047,  Lng: -121.329200),  Route carried "under" structure: City street F152,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 600 (year 2009),  Truck Traffic: 2%,  Features Intersected: MONTE DIABLO AVE,  Facility Carried by Structure: INTERSTATE 5
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 50.6m (166.0ft)

Find on map >>   Show street view

Structure Number: 29 0188R,  Location: 10-SJ-005-27.91-STKN (Lat: 37.957142,  Lng: -121.328633),  Route carried "under" structure: City street F152,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 550 (year 2009),  Truck Traffic: 5%,  Features Intersected: MONTE DIABLO AVE,  Facility Carried by Structure: INTERSTATE 5
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 50.6m (166.0ft)

Find on map >>   Show street view

Structure Number: 29 0189,  Location: 10-SJ-005-28.53-STKN (Lat: 37.964278,  Lng: -121.335111),  Route carried "under" structure: City street ,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 1998),  Truck Traffic: 10%,  Features Intersected: COUNTRY CLUB BLVD,  Facility Carried by Structure: INTERSTATE 5 NB
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 38.2m (125.3ft)

Find on map >>   Show street view

Structure Number: 29 0191,  Location: 10-SJ-005-28.97 (Lat: 37.970283,  Lng: -121.337489),  Route carried "under" structure: City street ,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 1998),  Truck Traffic: 10%,  Features Intersected: ALPINE AVE,  Facility Carried by Structure: INTERSTATE 5 NB
Minimum Vertical Clearance: 4.54m (14.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.0m (114.8ft)

Find on map >>   Show street view

Structure Number: 29 0192,  Location: 10-SJ-005-29.19 (Lat: 37.973403,  Lng: -121.338617),  Route carried "under" structure: City street ,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 1,200 (year 1998),  Truck Traffic: 10%,  Features Intersected: TELEGRAPH AVE,  Facility Carried by Structure: INTERSTATE 5 NB
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 30.0m (98.4ft)

Find on map >>   Show street view

Structure Number: 29 0193,  Location: 10-SJ-005-29.99-STKN (Lat: 37.984419,  Lng: -121.343078),  Route carried "under" structure: City street ,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 20,000 (year 1998),  Truck Traffic: 10%,  Features Intersected: W MARCH LANE,  Facility Carried by Structure: INTERSTATE 5 NB
Minimum Vertical Clearance: 4.59m (15.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 9,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 40.3m (132.2ft)

Find on map >>   Show street view

Structure Number: 29 0202S,  Location: 10-SJ-005-27.00-STKN (Lat: 37.956131,  Lng: -121.311667),  Route carried "under" structure: City street F158,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2009),  Truck Traffic: 2%,  Features Intersected: PARK STREET,  Facility Carried by Structure: I5-PERSHING AV OFF
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 34.7m (113.8ft)

Find on map >>   Show street view

Structure Number: 29 0209L,  Location: 10-SJ-005-35.30 (Lat: 38.057722,  Lng: -121.372722),  Route carried "under" structure: County highway ,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 2,038 (year 2000),  Truck Traffic: 5%,  Features Intersected: EIGHT MILE RD,  Facility Carried by Structure: INTERSTATE 5 SB
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>   Show street view

Structure Number: 29 0209R,  Location: 10-SJ-005-35.30 (Lat: 38.057731,  Lng: -121.372364),  Route carried "under" structure: County highway ,  Year Built: 1975,  Structure Length: 0. m,  Average Daily Traffic: 2,038 (year 2000),  Truck Traffic: 5%,  Features Intersected: EIGHT MILE RD,  Facility Carried by Structure: INTERSTATE 5 NB
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 40.6m (133.2ft)

Discuss Stockton, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.