  • National Bridge Inventory (NBI) Statistics
  • 1,085Number of bridges
  • 12,034ft / 3,668mTotal length
  • $82,595,000Total costs
  • 55,047,582Total average daily traffic
  • 3,107,918Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Detroit
  • No street view available for this location

New bridges in Detroit, MI - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 371900-1909
  • 431910-1919
  • 371920-1929
  • 331930-1939
  • 291940-1949
  • 2071950-1959
  • 2591960-1969
  • 2551970-1979
  • 361980-1989
  • 131990-1999
  • 762000-2009
  • 462010-2019
  • 132020-2022
Reconstructed bridges in Detroit, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31960-1969
  • 51970-1979
  • 221980-1989
  • 1161990-1999
  • 852000-2009
  • 272010-2019
Average Bridge Truck Traffic in Detroit, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.5%Excellent
  • 14.0%Very good
  • 41.7%Good
  • 25.6%Satisfactory
  • 10.8%Fair
  • 4.4%Poor
  • 1.0%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.3%Excellent
  • 15.1%Very good
  • 44.2%Good
  • 22.8%Satisfactory
  • 11.6%Fair
  • 3.5%Poor
  • 0.4%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.1%Excellent
  • 10.0%Very good
  • 41.9%Good
  • 30.9%Satisfactory
  • 12.2%Fair
  • 2.5%Poor
  • 0.4%Serious
  • 0.2%Failed
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 15.5%Very good
  • 30.9%Good
  • 25.5%Satisfactory
  • 22.7%Fair
  • 4.5%Poor
  • 0.9%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 5.0%Excellent
  • 40.0%Very good
  • 20.0%Satisfactory
  • 25.0%Fair
  • 5.0%Poor
  • 5.0%Serious
Find on map >>   Show street view

Structure Number: 12464,  Location: S OF JEFFERSON AVENUE (Lat: 42.324633,  Lng: -83.057439),  Route carried "under" structure: City street 2000,  Year Built: 1984,  Structure Length: 0. m,  Average Daily Traffic: 8,132 (year 2003),  Features Intersected: JEFFERSON AVE,  Facility Carried by Structure: SIXTH ST
Minimum Vertical Clearance: 6.60m (21.65ft),  Kilometerpoint: 2.932,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 12465,  Location: S OF W GRAND BLVD (Lat: 42.358736,  Lng: -83.083825),  Route carried "under" structure: City street ,  Year Built: 1916,  Structure Length: 0. m,  Average Daily Traffic: 420 (year 1977),  Features Intersected: COMMONWEALTH,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 3.91m (12.83ft),  Kilometerpoint: 0.311,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 8.5m (27.9ft)

Find on map >>   Show street view

Structure Number: 12466,  Location: S OF W GRAND BLVD (Lat: 42.358444,  Lng: -83.083658),  Route carried "under" structure: City street ,  Year Built: 1916,  Structure Length: 0. m,  Average Daily Traffic: 420 (year 1977),  Features Intersected: COMMONWEALTH,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 3.91m (12.83ft),  Kilometerpoint: 0.275,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 8.5m (27.9ft)

Find on map >>   Show street view

Structure Number: 12468,  Location: S OF FORD FREEWAY (Lat: 42.351139,  Lng: -83.089142),  Route carried "under" structure: City street ,  Year Built: 1908,  Structure Length: 0. m,  Average Daily Traffic: 671 (year 1977),  Features Intersected: FIFTEENTH,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 3.88m (12.73ft),  Kilometerpoint: 0.361,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 9.7m (31.8ft)

Find on map >>   Show street view

Structure Number: 12469,  Location: S OF FORD FREEWAY (Lat: 42.350800,  Lng: -83.088950),  Route carried "under" structure: City street ,  Year Built: 1908,  Structure Length: 0. m,  Average Daily Traffic: 671 (year 1977),  Features Intersected: FIFTEENTH,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 3.88m (12.73ft),  Kilometerpoint: 0.320,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 9.7m (31.8ft)

Find on map >>   Show street view

Structure Number: 12471,  Location: S OF W GRAND BLVD (Lat: 42.362639,  Lng: -83.080472),  Route carried "under" structure: City street ,  Year Built: 1916,  Structure Length: 0. m,  Average Daily Traffic: 3,225 (year 1976),  Features Intersected: HOLDEN,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.03m (13.22ft),  Kilometerpoint: 0.105,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 6.7m (22.0ft)

Find on map >>   Show street view

Structure Number: 12472,  Location: S OF W GRAND BLVD (Lat: 42.362664,  Lng: -83.080678),  Route carried "under" structure: City street ,  Year Built: 1916,  Structure Length: 0. m,  Average Daily Traffic: 3,225 (year 1976),  Features Intersected: HOLDEN,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.03m (13.22ft),  Kilometerpoint: 0.122,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 7.0m (23.0ft)

Find on map >>   Show street view

Structure Number: 12473,  Location: S OF W GRAND BLVD (Lat: 42.362708,  Lng: -83.081028),  Route carried "under" structure: City street ,  Year Built: 1916,  Structure Length: 0. m,  Average Daily Traffic: 3,225 (year 1976),  Features Intersected: HOLDEN,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 4.03m (13.22ft),  Kilometerpoint: 0.151,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 7.0m (23.0ft)

Find on map >>   Show street view

Structure Number: 12476,  Location: W OF JOHN R (Lat: 42.436972,  Lng: -83.104728),  Route carried "under" structure: City street ,  Year Built: 1938,  Structure Length: 0. m,  Average Daily Traffic: 2,159 (year 1978),  Features Intersected: LANTZ,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 1.006,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 12477,  Location: N OF MYRTLE (Lat: 42.336822,  Lng: -83.098992),  Route carried "under" structure: City street ,  Year Built: 1933,  Structure Length: 0. m,  Average Daily Traffic: 345 (year 1978),  Features Intersected: MCKINLEY,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.21m (13.81ft),  Kilometerpoint: 0.341,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 12478,  Location: N OF MYRTLE (Lat: 42.336567,  Lng: -83.098819),  Route carried "under" structure: City street ,  Year Built: 1933,  Structure Length: 0. m,  Average Daily Traffic: 345 (year 1978),  Features Intersected: MCKINLEY,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 4.21m (13.81ft),  Kilometerpoint: 0.309,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 12479,  Location: N OF TOLEDO (Lat: 42.319872,  Lng: -83.110200),  Route carried "under" structure: City street ,  Year Built: 1922,  Structure Length: 0. m,  Average Daily Traffic: 697 (year 1978),  Features Intersected: MILITARY,  Facility Carried by Structure: NS & CONRAIL RR
Minimum Vertical Clearance: 3.60m (11.81ft),  Kilometerpoint: 1.391,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 6.7m (22.0ft)

Find on map >>   Show street view

Structure Number: 1248,  Location: S OF JOHN KRONK (Lat: 42.324250,  Lng: -83.113836),  Route carried "under" structure: City street ,  Year Built: 1909,  Structure Length: 0. m,  Average Daily Traffic: 799 (year 1978),  Features Intersected: MILITARY,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 3.53m (11.58ft),  Kilometerpoint: 0.504,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 10.0m (32.8ft)

Find on map >>   Show street view

Structure Number: 12484,  Location: S OF BUCHANAN (Lat: 42.337753,  Lng: -83.098350),  Route carried "under" structure: City street ,  Year Built: 1933,  Structure Length: 0. m,  Average Daily Traffic: 590 (year 1978),  Features Intersected: ROOSEVELT,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.24m (13.91ft),  Kilometerpoint: 0.428,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 12485,  Location: S OF BUCHANAN (Lat: 42.337481,  Lng: -83.098172),  Route carried "under" structure: City street ,  Year Built: 1933,  Structure Length: 0. m,  Average Daily Traffic: 590 (year 1978),  Features Intersected: ROOSEVELT,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 4.24m (13.91ft),  Kilometerpoint: 0.394,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 12486,  Location: S OF FORD FREEWAY (Lat: 42.350206,  Lng: -83.089789),  Route carried "under" structure: City street ,  Year Built: 1908,  Structure Length: 0. m,  Average Daily Traffic: 342 (year 1977),  Features Intersected: SIXTEENTH,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 3.81m (12.50ft),  Kilometerpoint: 2.052,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 12487,  Location: S OF FORD FREEWAY (Lat: 42.349867,  Lng: -83.089597),  Route carried "under" structure: City street ,  Year Built: 1908,  Structure Length: 0. m,  Average Daily Traffic: 342 (year 1977),  Features Intersected: SIXTEENTH,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 3.81m (12.50ft),  Kilometerpoint: 2.010,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 12488,  Location: S OF BUCHANAN (Lat: 42.338586,  Lng: -83.097772),  Route carried "under" structure: City street ,  Year Built: 1932,  Structure Length: 0. m,  Average Daily Traffic: 416 (year 1978),  Features Intersected: TWENTY-FIFTH,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 0.483,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 12489,  Location: S OF BUCHANAN (Lat: 42.338311,  Lng: -83.097597),  Route carried "under" structure: City street ,  Year Built: 1932,  Structure Length: 0. m,  Average Daily Traffic: 416 (year 1978),  Features Intersected: TWENTY-FIFTH,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 0.449,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.8m (42.0ft)

Find on map >>   Show street view

Structure Number: 1249,  Location: S OF BUCHANAN (Lat: 42.340528,  Lng: -83.096428),  Route carried "under" structure: City street ,  Year Built: 1931,  Structure Length: 0. m,  Average Daily Traffic: 682 (year 1978),  Features Intersected: TWENTY-THIRD,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.21m (13.81ft),  Kilometerpoint: 0.621,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 8.2m (26.9ft)

Find on map >>   Show street view

Structure Number: 12491,  Location: S OF BUCHANAN (Lat: 42.340258,  Lng: -83.096250),  Route carried "under" structure: City street ,  Year Built: 1931,  Structure Length: 0. m,  Average Daily Traffic: 682 (year 1978),  Features Intersected: TWENTY-THIRD,  Facility Carried by Structure: GTW RR
Minimum Vertical Clearance: 4.21m (13.81ft),  Kilometerpoint: 0.587,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 8.2m (26.9ft)

Find on map >>   Show street view

Structure Number: 12712,  Location: FORT ST (Lat: 42.283503,  Lng: -83.149192),  Route carried "under" structure: City street ,  Year Built: 2010,  Structure Length: 0. m,  Average Daily Traffic: 2,630 (year 1987),  Features Intersected: PLEASANT ST,  Facility Carried by Structure: M-85 (FORT ST)
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.307,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.7m (61.4ft)

Find on map >>   Show street view

Structure Number: 1281,  Location: I-75 & I-375 INTERCHANGE (Lat: 42.342425,  Lng: -83.046083),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 42,500 (year 1995),  Truck Traffic: 15%,  Features Intersected: I-75 SB TO EB RAMP,  Facility Carried by Structure: BRUSH ST ENTR RMP
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 0.275,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 8.8m (28.9ft)

Find on map >>   Show street view

Structure Number: 1318,  Location: IN DETROIT (Lat: 42.328111,  Lng: -83.086611),  Route carried "under" structure: Interstate 75,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 57,000 (year 1995),  Truck Traffic: 22%,  Features Intersected: W BD SERV RD& I-75/I-96,  Facility Carried by Structure: CPR - CONRAIL
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 1.674,  Lanes under structure: 10,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 13312,  Location: AMBASSADOR GATEWAY (Lat: 42.320347,  Lng: -83.081986),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 23,050 (year 2015),  Truck Traffic: 13%,  Features Intersected: I-75 AND I-96
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 9.219,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 53.4m (175.2ft)

Find on map >>   Show street view

Structure Number: 13312,  Location: AMBASSADOR GATEWAY (Lat: 42.320347,  Lng: -83.081986),  Route carried "under" structure: Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 21,750 (year 2015),  Truck Traffic: 13%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: SB I-75 RMP TO TP
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 9.172,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 53.4m (175.2ft)

Find on map >>   Show street view

Structure Number: 13312,  Location: AMBASSADOR GATEWAY (Lat: 42.320347,  Lng: -83.081986),  Route carried "under" structure: Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 21,750 (year 2015),  Truck Traffic: 13%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: SB I-75 RMP TO TP
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 9.219,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 53.4m (175.2ft)

Find on map >>   Show street view

Structure Number: 13312,  Location: AMBASSADOR GATEWAY (Lat: 42.320347,  Lng: -83.081986),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 37,004 (year 2015),  Truck Traffic: 13%,  Features Intersected: I-75 AND I-96
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 34.119,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 53.4m (175.2ft)

Find on map >>   Show street view

Structure Number: 13313,  Location: AMBASSADOR GATEWAY (Lat: 42.321628,  Lng: -83.082819),  Route carried "under" structure: Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 35,000 (year 0000),  Features Intersected: EB I-96,  Facility Carried by Structure: SB I-75 EXIT RAMP
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 9.074,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.8m (117.5ft)

Find on map >>   Show street view

Structure Number: 13314,  Location: AMBASSADOR GATEWAY (Lat: 42.320828,  Lng: -83.082153),  Route carried "under" structure: Ramp Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 1,030 (year 2013),  Features Intersected: I-75 AND WB I-96,  Facility Carried by Structure: SB I-75 RMP TO VER
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.9m (127.6ft)

Find on map >>   Show street view

Structure Number: 13314,  Location: AMBASSADOR GATEWAY (Lat: 42.320828,  Lng: -83.082153),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 5,490 (year 2013),  Truck Traffic: 9%,  Features Intersected: I-75 AND WB I-96
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 34.205,  Lanes on structure: 1,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.9m (127.6ft)

Find on map >>   Show street view

Structure Number: 13315,  Location: AMBASSADOR GATEWAY (Lat: 42.320628,  Lng: -83.081594),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 3,914 (year 2010),  Truck Traffic: 99%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: TRK RMP FRM TP
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.404,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 13315,  Location: AMBASSADOR GATEWAY (Lat: 42.320628,  Lng: -83.081594),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 1,390 (year 2013),  Truck Traffic: 99%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: TRK RMP FRM TP
Minimum Vertical Clearance: 5.87m (19.26ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 13315,  Location: AMBASSADOR GATEWAY (Lat: 42.320628,  Lng: -83.081594),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 1,060 (year 2010),  Truck Traffic: 99%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: TRK RMP FRM TP
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.206,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 13316,  Location: AMBASSADOR GATEWAY (Lat: 42.321775,  Lng: -83.082183),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 1,060 (year 2010),  Truck Traffic: 99%,  Features Intersected: NB I-75,  Facility Carried by Structure: WB -96 RMP FRM TP
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 0.011,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 68.0m (223.1ft)

Find on map >>   Show street view

Structure Number: 13316,  Location: AMBASSADOR GATEWAY (Lat: 42.321775,  Lng: -83.082183),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 37,004 (year 2015),  Truck Traffic: 99%,  Features Intersected: NB I-75,  Facility Carried by Structure: WB -96 RMP FRM TP
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 34.300,  Lanes on structure: 1,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 68.0m (223.1ft)

Find on map >>   Show street view

Structure Number: 13317,  Location: AMBASSADOR GATEWAY (Lat: 42.322311,  Lng: -83.081717),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 2,500 (year 0000),  Features Intersected: NB I-75 RMP TO VERNOR
Minimum Vertical Clearance: 9.75m (31.99ft),  Kilometerpoint: 0.116,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 13318,  Location: AMBASSADOR GATEWAY (Lat: 42.322836,  Lng: -83.082700),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 37,004 (year 2015),  Truck Traffic: 40%,  Features Intersected: I-75 AND I-96
Minimum Vertical Clearance: 10.52m (34.51ft),  Kilometerpoint: 34.414,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.8m (153.5ft)

Find on map >>   Show street view

Structure Number: 13318,  Location: AMBASSADOR GATEWAY (Lat: 42.322836,  Lng: -83.082700),  Route carried "under" structure: Ramp Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 1,390 (year 2015),  Truck Traffic: 40%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: RMP TO SB I-75
Minimum Vertical Clearance: 6.76m (22.18ft),  Kilometerpoint: 0.233,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.8m (153.5ft)

Find on map >>   Show street view

Structure Number: 13318,  Location: AMBASSADOR GATEWAY (Lat: 42.322836,  Lng: -83.082700),  Route carried "under" structure: Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 21,750 (year 2015),  Truck Traffic: 40%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: RMP TO SB I-75
Minimum Vertical Clearance: 10.87m (35.66ft),  Kilometerpoint: 8.960,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.8m (153.5ft)

Find on map >>   Show street view

Structure Number: 13318,  Location: AMBASSADOR GATEWAY (Lat: 42.322836,  Lng: -83.082700),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 640 (year 2015),  Truck Traffic: 40%,  Features Intersected: I-75 AND I-96
Minimum Vertical Clearance: 8.33m (27.33ft),  Kilometerpoint: 0.229,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.8m (153.5ft)

Find on map >>   Show street view

Structure Number: 13318,  Location: AMBASSADOR GATEWAY (Lat: 42.322836,  Lng: -83.082700),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 4,410 (year 2015),  Truck Traffic: 40%,  Features Intersected: I-75 AND I-96
Minimum Vertical Clearance: 10.69m (35.07ft),  Kilometerpoint: 34.628,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.8m (153.5ft)

Find on map >>   Show street view

Structure Number: 13318,  Location: AMBASSADOR GATEWAY (Lat: 42.322836,  Lng: -83.082700),  Route carried "under" structure: Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 21,750 (year 2015),  Truck Traffic: 40%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: RMP TO SB I-75
Minimum Vertical Clearance: 10.67m (35.01ft),  Kilometerpoint: 8.964,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.8m (153.5ft)

Find on map >>   Show street view

Structure Number: 13318,  Location: AMBASSADOR GATEWAY (Lat: 42.322836,  Lng: -83.082700),  Route carried "under" structure: Ramp Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 5,484 (year 2015),  Truck Traffic: 40%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: RMP TO SB I-75
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.246,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 46.8m (153.5ft)

Find on map >>   Show street view

Structure Number: 13319,  Location: AMBASSADOR GATEWAY (Lat: 42.322961,  Lng: -83.082125),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 8,700 (year 0000),  Features Intersected: I-75 NB&SB RMP TO VERNOR
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 0.423,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.7m (130.2ft)

Find on map >>   Show street view

Structure Number: 13319,  Location: AMBASSADOR GATEWAY (Lat: 42.322961,  Lng: -83.082125),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 8,700 (year 0000),  Truck Traffic: 12%,  Features Intersected: I-75 NB&SB RMP TO VERNOR
Minimum Vertical Clearance: 6.20m (20.34ft),  Kilometerpoint: 0.150,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.7m (130.2ft)

Find on map >>   Show street view

Structure Number: 1332,  Location: AMBASSADOR GATEWAY (Lat: 42.323694,  Lng: -83.083833),  Route carried "under" structure: Interstate 96,  Year Built: 2007,  Structure Length: 0. m,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: BAGLEY AVE PED
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stayed Girder,  Length of Maximum Span: 84.1m (275.9ft)

Find on map >>   Show street view

Structure Number: 1332,  Location: AMBASSADOR GATEWAY (Lat: 42.323694,  Lng: -83.083833),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 77,000 (year 2009),  Truck Traffic: 24%,  Features Intersected: I-75 AND I-96,  Facility Carried by Structure: BAGLEY AVE PED
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.570,  Lanes under structure: 12,  Material/Design: Steel continuous,  Design/Construction: Stayed Girder,  Length of Maximum Span: 84.1m (275.9ft)

Find on map >>   Show street view

Structure Number: 134,  Location: AMBASSADOR GATEWAY (Lat: 42.322950,  Lng: -83.082350),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Features Intersected: I-75 NB AND VERNOR RAMPS,  Facility Carried by Structure: PLAZA TO I-96 WB
Minimum Vertical Clearance: 5.94m (19.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.6m (172.6ft)

Find on map >>   Show street view

Structure Number: 134,  Location: AMBASSADOR GATEWAY (Lat: 42.322950,  Lng: -83.082350),  Route carried "under" structure: Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Features Intersected: I-75 NB AND VERNOR RAMPS,  Facility Carried by Structure: PLAZA TO I-96 WB
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.6m (172.6ft)

Find on map >>   Show street view

Structure Number: 134,  Location: AMBASSADOR GATEWAY (Lat: 42.322950,  Lng: -83.082350),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 10 (year 0000),  Features Intersected: I-75 NB AND VERNOR RAMPS,  Facility Carried by Structure: PLAZA TO I-96 WB
Minimum Vertical Clearance: 6.10m (20.01ft),  Kilometerpoint: 34.433,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.6m (172.6ft)

Find on map >>   Show street view

Structure Number: 13403,  Location: AMBASSADOR GATEWAY (Lat: 42.322583,  Lng: -83.081528),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 862 (year 2010),  Features Intersected: NB&SB RMPS TO VERNOR
Minimum Vertical Clearance: 9.73m (31.92ft),  Kilometerpoint: 0.116,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 60.2m (197.5ft)

Find on map >>   Show street view

Structure Number: 13403,  Location: AMBASSADOR GATEWAY (Lat: 42.322583,  Lng: -83.081528),  Route carried "under" structure: Ramp Interstate 75,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 1,060 (year 2010),  Truck Traffic: 40%,  Features Intersected: NB&SB RMPS TO VERNOR
Minimum Vertical Clearance: 8.56m (28.08ft),  Kilometerpoint: 0.407,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 60.2m (197.5ft)

Find on map >>   Show street view

Structure Number: 13499,  Location: IN DETROIT (Lat: 42.397731,  Lng: -83.109147),  Route carried "under" structure: Ramp State highway 8,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 30,000 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-8 RAMP TO M-10 SB,  Facility Carried by Structure: M-10 WB
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 0.344,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 13531,  Location: S OF MICHIGAN AVE (Lat: 42.325567,  Lng: -83.107419),  Route carried "under" structure: City street ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2015),  Features Intersected: JUNCTION AVE,  Facility Carried by Structure: CN RR
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 2.718,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 22.1m (72.5ft)

Find on map >>   Show street view

Structure Number: 14043,  Location: IN DETROIT (Lat: 42.343353,  Lng: -83.068100),  Route carried "under" structure: State highway 10,  Year Built: 2017,  Structure Length: 0. m,  Average Daily Traffic: 98,775 (year 2018),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: MLK JR BLVD WB
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 17.222,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 22.7m (74.5ft)

Discuss Detroit, Michigan (MI) on our hugely popular Michigan forum.